Accuenergy Acuvim-CL Series Multifunction Power and Energy Meter with panel mounting with display, AcuCT-Flex input & 333 mV input, 20 to 60 V DC

Modèle: ACUVIM-CL-D-MV-P2V4

Accuenergy Acuvim-CL Series Multifunction Power and Energy Meter with panel mounting with display, AcuCT-Flex input & 333 mV input, 20 to 60 V DC

Modèle: ACUVIM-CL-D-MV-P2V4

Ideal for various standard metering projects, this multifunction power meter with energy class 0.5 harmonics up to 31st provides real-time, true-RMS measurements of current, power, voltage, energy, and many other parameters. In addition, it has an AcuCT-Flex current input, a 20 to 60 V DC power supply, and a standard mount.

Ideal for various standard metering projects, this multifunction power meter with energy class 0.5 harmonics up to 31st provides real-time, true-RMS measurements of current, power, voltage, energy, and many other parameters. In addition, it has an AcuCT-Flex current input, a 20 to 60 V DC power supply, and a standard mount.

Prix spécial $614.10 CAD
Prix régulier $667.50 CAD
Disponibilité 2 à 3 semaines
Quantité

À propos de l'Acuvim-CL

Le compteur d'énergie/puissance multifonction Acuvim-CL pour une ou trois phases peut être utilisé comme dispositif de collecte de données dans un système de distribution électrique intelligent. Toutes les données de surveillance sont disponibles via un port de communication numérique RS485 utilisant le protocole Modbus. Disponible avec écran LCD ou en version transducteur pour rail DIN (sans affichage).

L’Acuvim-CL utilise le protocole Modbus RTU standard de l’industrie.


La série Acuvim-L

Les compteurs d’énergie multifonction de la série Acuvim-L sont fabriqués par Accuenergy. Ils constituent le choix idéal pour la surveillance et le contrôle des systèmes de distribution électrique.

L’Acuvim-L peut être utilisé comme dispositif de collecte de données dans un système de distribution électrique intelligent ou un système d'automatisation d'usine. Toutes les données de surveillance sont disponibles via un port de communication RS485 utilisant le protocole Modbus® (hors modèles Acuvim AL et BL).

La qualité du système électrique est importante en raison de l'utilisation croissante de charges électroniques telles que les ordinateurs, les ballasts ou les variateurs de fréquence. Avec l’option d’analyse de puissance de l’Acuvim-L, n’importe quel courant ou tension de phase peut être affiché et le contenu harmonique calculé. En connaissant la distribution harmonique, des actions peuvent être prises pour éviter la surchauffe des transformateurs, moteurs, condensateurs, fils neutres et les déclenchements intempestifs des disjoncteurs. Une redistribution des charges du système peut également être envisagée.


Pour les fonctions d’Heures Pleines/Heures Creuses (HP/HC), veuillez consulter le Acuvim-EL.


Caractéristiques principales

Mesures

  • Tension V1, V2, V3, V12, V23, V31
  • Courant I1, I2, I3, In
  • Puissance P1, P2, P3, Ptot
  • Puissance réactive Q1, Q2, Q3, Qtot
  • Puissance apparente S1, S2, S3, Stot
  • Fréquence F
  • Facteur de puissance PF1, PF2, PF3, PF
  • Énergie active Ep_imp, Ep_exp
  • Énergie réactive Eq_imp, Eq_exp
  • Énergie apparente Es
  • Puissance appelée Dmd_I1, Dmd_I2, Dmd_I3, Dmd_P, Dmd_Q, Dmd_S

Surveillance

  • Qualité de l’énergie (fonctions non incluses avec l’Acuvim-KL)
  • Harmoniques de tension de la 2e à la 15e et THD (Acuvim-DL : 2e à la 25e)
  • Harmoniques de courant de la 2e à la 15e et THD (Acuvim-DL : 2e à la 25e)
  • Taux de déséquilibre de tension U_unbl (sauf modèles KL)
  • Taux de déséquilibre de courant I_unbl (sauf modèles KL)
  • Statistiques Max/Min (sauf modèles KL)
  • Durée de fonctionnement du compteur et durée de fonctionnement de la charge (DL/EL/KL)

Alarmes

Deux (2) paramètres peuvent être définis sur un intervalle de temps spécifique. Si un paramètre dépasse ou descend en dessous de la limite définie et que cela persiste durant cet intervalle, l'événement sera enregistré avec horodatage et déclenchera la sortie d’alarme DO. Le paramètre peut être choisi parmi 35 disponibles.

Communication

RS485, protocole standard Modbus® RTU ; (modèles CL/DL/EL/KL uniquement)
Option second RS485, protocole Modbus® RTU ; ou PROFIBUS-DP/V0 (disponible pour les modèles DL/EL)

Affichage

Affichage ACL clair avec rétroéclairage blanc ;
Résistance étendue aux températures environnementales.


Logiciel Acuview

Avec la nécessité croissante de mieux comprendre la consommation d’énergie, Accuenergy propose un logiciel simple et efficace pour compléter ses compteurs. Combiné aux compteurs, la suite logicielle Acuview offre une solution de surveillance et de mesure puissante et économique.

Fonctionnalités du logiciel Acuview

  • Configuration simple pour un déploiement rapide des compteurs Accuenergy.
  • Surveillance à distance et en temps réel de tous les paramètres.
  • Des dizaines de compteurs peuvent être connectés à un seul PC.
  • Affichage simultané de plusieurs compteurs dans une seule fenêtre.
  • Enregistrement des données en temps réel.
  • Journalisation des données des modules d’E/S (impulsions d’eau, de gaz, de débit, etc).
  • Données exportées dans des tableaux Excel simples (.xls, .csv ou .txt).
  • La fonction SmartSum fournit des données d’énergie et de puissance appelées moyennes du système surveillé.

Applications

  • Mesure de l’énergie des départs de distribution, transformateurs, générateurs, batteries de condensateurs et moteurs.
  • Systèmes moyenne et basse tension.
  • Installations commerciales, industrielles, services publics.
  • Analyse de la qualité de l’énergie.

La série Acuvim L est compatible avec le montage sur rail DIN

Options de montage et d’affichage

La série Acuvim II est disponible avec deux options de montage :

Standard avec écran ACL

Le modèle standard est conforme à la norme ANSI C39.1 avec un format compact 96x96.

Montage sur rail DIN (affichage ACL distant en option)

Les unités compatibles DIN respectent la norme DIN 43700. La série Acuvim L propose également un écran ACL distant en option.


Schéma de câblage typique de la série Acuvim L

Schémas de câblage typiques de la série Acuvim L

Spécifications pour le Accuenergy ACUVIM-CL-D-MV-P2V4

Current Inputs (Each Channel) Nominal current options:
1: 5 A
2: 1 A
3: 1 A (333 mV)
4: 1 A (100 mV Rope CT)

Metering range:
1: 0 to 10 A
2: 0 to 2 A
3: 0 to 1.2 A
4: 0 to 1.2 A

Pickup current:
1: 5 mA
2: 1 mA
3: 5 mA
4: 5 mA

Withstand:
20 Arms continuous, 0.1% of nominal
100 Arms for 1 second, non-recurring

Burden: 0.05 V A (typical) at 5 A RMS

Accuracy: 0.1% at reading
Voltage Inputs (Each Channel) Nominal full scale: 400 V AC L-N, 690 V AC L-L (+20%)
Withstand: 1500 V AC continuous; 2500 V AC, 50/60 Hz for 1 minute
Input impedance: 2 MΩ per phase
Metering frequency: 45 to 65 Hz, 300 to 500 Hz
Pickup voltage: 10 V AC
Accuracy: 0.1% at reading
Energy Accuracy Active: Class 0.5s (IEC 62053-22), Class 0.5s (ANSI C12.20)
Reactive: Class 0.5 (IEC62053-24)
Harmonic Resolution Metered value: 2nd to 31st Harmonic (50 or 60 Hz type)
Communications Modbus-RTU or BACnet MS/TP: Modbus-RTU
2-wire shielded twisted pair cable connection 1200 to 115,200 bps
Control Power Universal: AC or DC

Operating Range: 100 to 415 V AC, 50/60 Hz; 100 to 300 V DC
Burden: 5 W
Frequency: 50/60 Hz
Withstand: 3250 V AC, 50/60 Hz for 1 minute
Installation Category III (Distribution)
Power Supply: 100 to 415 V AC, 50/60 Hz, 100 to 300 V DC
Consumption: 3 W
Environmental Conditions Operating temperature: -13 to 158°F (-25 to 70°C)
Storage temperature: -40 to 176°F (-40 to 85°C)
Relative humidity: 5 to 95% non-condensing
Protection Level IP56 (front), IP30 (cover)
Standard Compliance and Certifications Measurement standard: IEC 62053-22, ANSI C12.20, IEC61557-12
Environmental standard: IEC 60068-2, CE, RoHS
Safety standard: IEC 61010-1, UL 61010-1
EMC standard: IEC 61000-4/-2-3-4-5-6-8-11, CISPR 22, IEC 61000-3-2, IEC 61000-6-2/4
Outlines standard: DIN 43700, ANSI C39.1
Protocol conformance: IEC 61850 2nd Edition
Dimensions 3.8 x 3.8 x 2" (96 x 96 x 50.7 mm)
Cut-out: 3.62 x 3.62" (92 x 92 mm) or 4" (102 mm) round
Weight 0.77 lbs (350 g)

Le Accuenergy ACUVIM-CL-D-MV-P2V4 comprend

  • Accuenergy Acuvim-CL Series Multifunction Power and Energy Meter with panel mounting with display, AcuCT-Flex input & 333 mV input, 20 to 60 V DC

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Accuenergy Acuvim-CL Series Multifunction Power and Energy Meter with panel mounting with display, AcuCT-Flex input & 333 mV input, 20 to 60 V DC.

Accuenergy AXM-DIN Rail Mounting Adapter for the Acuvim II/Acuvim IIBN/Acuvim L, 1.37" DIN AXM-DIN
Compatible with the Acuvim II, Acuvim IIBN, and Acuvim-L series energy meters, this rail mounting adapter allows for easy installation on either a horizontal or vertical DIN rail mount.




MODBUS RS485 to USB Adapter USB-RS485
MODBUS RS485 to USB Adapter converts MODBUS data running via RS485 to USB for use on local PC.




Accuenergy IP66/NEMA4X Protection Cover for the Acuvim II/Acuvim-L, 4.21 x 4.21" 96-IP66
Compatible with 96 x 96 meters, this screen protector is an accessory or replacement part.




Poser une question sur le Accuenergy Acuvim-CL Series Multifunction Power and Energy Meter with panel mounting with display, AcuCT-Flex input & 333 mV input, 20 to 60 V DC

À propos de l'Acuvim-CL

Le compteur d'énergie/puissance multifonction Acuvim-CL pour une ou trois phases peut être utilisé comme dispositif de collecte de données dans un système de distribution électrique intelligent. Toutes les données de surveillance sont disponibles via un port de communication numérique RS485 utilisant le protocole Modbus. Disponible avec écran LCD ou en version transducteur pour rail DIN (sans affichage).

L’Acuvim-CL utilise le protocole Modbus RTU standard de l’industrie.


La série Acuvim-L

Les compteurs d’énergie multifonction de la série Acuvim-L sont fabriqués par Accuenergy. Ils constituent le choix idéal pour la surveillance et le contrôle des systèmes de distribution électrique.

L’Acuvim-L peut être utilisé comme dispositif de collecte de données dans un système de distribution électrique intelligent ou un système d'automatisation d'usine. Toutes les données de surveillance sont disponibles via un port de communication RS485 utilisant le protocole Modbus® (hors modèles Acuvim AL et BL).

La qualité du système électrique est importante en raison de l'utilisation croissante de charges électroniques telles que les ordinateurs, les ballasts ou les variateurs de fréquence. Avec l’option d’analyse de puissance de l’Acuvim-L, n’importe quel courant ou tension de phase peut être affiché et le contenu harmonique calculé. En connaissant la distribution harmonique, des actions peuvent être prises pour éviter la surchauffe des transformateurs, moteurs, condensateurs, fils neutres et les déclenchements intempestifs des disjoncteurs. Une redistribution des charges du système peut également être envisagée.


Pour les fonctions d’Heures Pleines/Heures Creuses (HP/HC), veuillez consulter le Acuvim-EL.


Caractéristiques principales

Mesures

  • Tension V1, V2, V3, V12, V23, V31
  • Courant I1, I2, I3, In
  • Puissance P1, P2, P3, Ptot
  • Puissance réactive Q1, Q2, Q3, Qtot
  • Puissance apparente S1, S2, S3, Stot
  • Fréquence F
  • Facteur de puissance PF1, PF2, PF3, PF
  • Énergie active Ep_imp, Ep_exp
  • Énergie réactive Eq_imp, Eq_exp
  • Énergie apparente Es
  • Puissance appelée Dmd_I1, Dmd_I2, Dmd_I3, Dmd_P, Dmd_Q, Dmd_S

Surveillance

  • Qualité de l’énergie (fonctions non incluses avec l’Acuvim-KL)
  • Harmoniques de tension de la 2e à la 15e et THD (Acuvim-DL : 2e à la 25e)
  • Harmoniques de courant de la 2e à la 15e et THD (Acuvim-DL : 2e à la 25e)
  • Taux de déséquilibre de tension U_unbl (sauf modèles KL)
  • Taux de déséquilibre de courant I_unbl (sauf modèles KL)
  • Statistiques Max/Min (sauf modèles KL)
  • Durée de fonctionnement du compteur et durée de fonctionnement de la charge (DL/EL/KL)

Alarmes

Deux (2) paramètres peuvent être définis sur un intervalle de temps spécifique. Si un paramètre dépasse ou descend en dessous de la limite définie et que cela persiste durant cet intervalle, l'événement sera enregistré avec horodatage et déclenchera la sortie d’alarme DO. Le paramètre peut être choisi parmi 35 disponibles.

Communication

RS485, protocole standard Modbus® RTU ; (modèles CL/DL/EL/KL uniquement)
Option second RS485, protocole Modbus® RTU ; ou PROFIBUS-DP/V0 (disponible pour les modèles DL/EL)

Affichage

Affichage ACL clair avec rétroéclairage blanc ;
Résistance étendue aux températures environnementales.


Logiciel Acuview

Avec la nécessité croissante de mieux comprendre la consommation d’énergie, Accuenergy propose un logiciel simple et efficace pour compléter ses compteurs. Combiné aux compteurs, la suite logicielle Acuview offre une solution de surveillance et de mesure puissante et économique.

Fonctionnalités du logiciel Acuview

  • Configuration simple pour un déploiement rapide des compteurs Accuenergy.
  • Surveillance à distance et en temps réel de tous les paramètres.
  • Des dizaines de compteurs peuvent être connectés à un seul PC.
  • Affichage simultané de plusieurs compteurs dans une seule fenêtre.
  • Enregistrement des données en temps réel.
  • Journalisation des données des modules d’E/S (impulsions d’eau, de gaz, de débit, etc).
  • Données exportées dans des tableaux Excel simples (.xls, .csv ou .txt).
  • La fonction SmartSum fournit des données d’énergie et de puissance appelées moyennes du système surveillé.

Applications

  • Mesure de l’énergie des départs de distribution, transformateurs, générateurs, batteries de condensateurs et moteurs.
  • Systèmes moyenne et basse tension.
  • Installations commerciales, industrielles, services publics.
  • Analyse de la qualité de l’énergie.

La série Acuvim L est compatible avec le montage sur rail DIN

Options de montage et d’affichage

La série Acuvim II est disponible avec deux options de montage :

Standard avec écran ACL

Le modèle standard est conforme à la norme ANSI C39.1 avec un format compact 96x96.

Montage sur rail DIN (affichage ACL distant en option)

Les unités compatibles DIN respectent la norme DIN 43700. La série Acuvim L propose également un écran ACL distant en option.


Schéma de câblage typique de la série Acuvim L

Schémas de câblage typiques de la série Acuvim L

Spécifications pour le Accuenergy ACUVIM-CL-D-MV-P2V4

Current Inputs (Each Channel) Nominal current options:
1: 5 A
2: 1 A
3: 1 A (333 mV)
4: 1 A (100 mV Rope CT)

Metering range:
1: 0 to 10 A
2: 0 to 2 A
3: 0 to 1.2 A
4: 0 to 1.2 A

Pickup current:
1: 5 mA
2: 1 mA
3: 5 mA
4: 5 mA

Withstand:
20 Arms continuous, 0.1% of nominal
100 Arms for 1 second, non-recurring

Burden: 0.05 V A (typical) at 5 A RMS

Accuracy: 0.1% at reading
Voltage Inputs (Each Channel) Nominal full scale: 400 V AC L-N, 690 V AC L-L (+20%)
Withstand: 1500 V AC continuous; 2500 V AC, 50/60 Hz for 1 minute
Input impedance: 2 MΩ per phase
Metering frequency: 45 to 65 Hz, 300 to 500 Hz
Pickup voltage: 10 V AC
Accuracy: 0.1% at reading
Energy Accuracy Active: Class 0.5s (IEC 62053-22), Class 0.5s (ANSI C12.20)
Reactive: Class 0.5 (IEC62053-24)
Harmonic Resolution Metered value: 2nd to 31st Harmonic (50 or 60 Hz type)
Communications Modbus-RTU or BACnet MS/TP: Modbus-RTU
2-wire shielded twisted pair cable connection 1200 to 115,200 bps
Control Power Universal: AC or DC

Operating Range: 100 to 415 V AC, 50/60 Hz; 100 to 300 V DC
Burden: 5 W
Frequency: 50/60 Hz
Withstand: 3250 V AC, 50/60 Hz for 1 minute
Installation Category III (Distribution)
Power Supply: 100 to 415 V AC, 50/60 Hz, 100 to 300 V DC
Consumption: 3 W
Environmental Conditions Operating temperature: -13 to 158°F (-25 to 70°C)
Storage temperature: -40 to 176°F (-40 to 85°C)
Relative humidity: 5 to 95% non-condensing
Protection Level IP56 (front), IP30 (cover)
Standard Compliance and Certifications Measurement standard: IEC 62053-22, ANSI C12.20, IEC61557-12
Environmental standard: IEC 60068-2, CE, RoHS
Safety standard: IEC 61010-1, UL 61010-1
EMC standard: IEC 61000-4/-2-3-4-5-6-8-11, CISPR 22, IEC 61000-3-2, IEC 61000-6-2/4
Outlines standard: DIN 43700, ANSI C39.1
Protocol conformance: IEC 61850 2nd Edition
Dimensions 3.8 x 3.8 x 2" (96 x 96 x 50.7 mm)
Cut-out: 3.62 x 3.62" (92 x 92 mm) or 4" (102 mm) round
Weight 0.77 lbs (350 g)

Le Accuenergy ACUVIM-CL-D-MV-P2V4 comprend

  • Accuenergy Acuvim-CL Series Multifunction Power and Energy Meter with panel mounting with display, AcuCT-Flex input & 333 mV input, 20 to 60 V DC

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Accuenergy Acuvim-CL Series Multifunction Power and Energy Meter with panel mounting with display, AcuCT-Flex input & 333 mV input, 20 to 60 V DC.

Accuenergy AXM-DIN Rail Mounting Adapter for the Acuvim II/Acuvim IIBN/Acuvim L, 1.37" DIN AXM-DIN
Compatible with the Acuvim II, Acuvim IIBN, and Acuvim-L series energy meters, this rail mounting adapter allows for easy installation on either a horizontal or vertical DIN rail mount.




MODBUS RS485 to USB Adapter USB-RS485
MODBUS RS485 to USB Adapter converts MODBUS data running via RS485 to USB for use on local PC.




Accuenergy IP66/NEMA4X Protection Cover for the Acuvim II/Acuvim-L, 4.21 x 4.21" 96-IP66
Compatible with 96 x 96 meters, this screen protector is an accessory or replacement part.




Poser une question sur le Accuenergy Acuvim-CL Series Multifunction Power and Energy Meter with panel mounting with display, AcuCT-Flex input & 333 mV input, 20 to 60 V DC

Plus de produits Accuenergy