Accuenergy AcuRev 1314-5A-X1 DIN Rail Power/Energy Meter, 5 A/1 A CT input, relay output

Modèle: AcuRev-1314-5A-X1 | No. de commande: AcuRev 1314-5A-X1

Accuenergy AcuRev 1314-5A-X1 DIN Rail Power/Energy Meter, 5 A/1 A CT input, relay output

Modèle: AcuRev-1314-5A-X1 | No. de commande: AcuRev 1314-5A-X1

Three-phase multi-circuit power and energy meter tracks active, reactive and apparent energy and power, as well as power and current demand, offers revenue grade accuracy, features built-in pulse/alarm output and optional relay output, accepts user configurable current transformer (CT) input, takes bi-directional energy measurements and calculates residual current measurements.

Three-phase multi-circuit power and energy meter tracks active, reactive and apparent energy and power, as well as power and current demand, offers revenue grade accuracy, features built-in pulse/alarm output and optional relay output, accepts user configurable current transformer (CT) input, takes bi-directional energy measurements and calculates residual current measurements.

Prix spécial $614.90 CAD
Prix régulier $715.00 CAD
Disponibilité 1 à 2 semaines
Quantité

Spécifications pour le Accuenergy AcuRev-1314-5A-X1

Parameter AccuracyResolutionRange
Active Energy 0.50%1Wh0 to 999999999kWh
Reactive Energy 0.50%1varh0 to 999999999kvarh
Apparent Energy 0.50%1VAh0 to 999999999kVAh
Voltage 0.50%0.110V to 1000KV
Current 0.50%0.001A10mA to 500000A
Active Power 0.50%1W-99 to 99MW
Reactive Power 0.50%1var-99 to 99Mvar
Apparent Power 0.50%1VA-99 to 99MVA
Power Factor 0.50%0.001-1.000 to 1.000
Frequency 0.20%0.01Hz50/60Hz
Power Demand 0.50%1W/var/VA99MW/Mvar/MVA
Current Demand 0.50%0.001A10mA to 5000A

Le Accuenergy AcuRev-1314-5A-X1 comprend

  • Accuenergy AcuRev 1314-5A-X1 DIN Rail Power/Energy Meter, 5 A/1 A CT input, relay output

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Accuenergy AcuRev 1314-5A-X1 DIN Rail Power/Energy Meter, 5 A/1 A CT input, relay output.

Accuenergy AcuCT-0812-200:5 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 200 A:5 A AcuCT-0812-200:5
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 200 A et une sortie de 5 A.




Accuenergy AcuCT-0812-200:1 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 200 A:1 A AcuCT-0812-200:1
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 200 A et une sortie de 1 A.




Accuenergy AcuCT-0812-250:1 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 250 A:1 A AcuCT-0812-250:1
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 250 A et une sortie de 1 A.




Accuenergy AcuCT-0812-250:5 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 250 A:5 A AcuCT-0812-250:5
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 250 A et une sortie de 5 A.




Accuenergy AcuCT-0812-300:1 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 300 A:1 A AcuCT-0812-300:1
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 300 A et une sortie de 1 A.




Accuenergy AcuCT-0812-300:5 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 300 A:5 A AcuCT-0812-300:5
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 300 A et une sortie de 5 A.




Accuenergy AcuCT-0812-400:1 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 400 A:1 A AcuCT-0812-400:1
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 400 A et une sortie de 1 A.




Accuenergy AcuCT-2031-400:1 Split Core Current Transformer, 0.83 x 1.22", 400 A:1 A AcuCT-2031-400:1
Split core current transformer features a window size of 1.97 x 3.15quot;, current input of 400 A and output of 1 A.




Accuenergy AcuCT-2031-400:5 Transformateur de courant à noyau divisé, 0.83 x 1.22", 400 A: 5 A AcuCT-2031-400:5
Transformateur de courant à noyau fendu, avec fenêtre de 50 x 80 mm, entrée de courant de 400 A et sortie de 5 A.




Accuenergy AcuCT-0812-400:5 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 400 A:5 A AcuCT-0812-400:5
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 400 A et une sortie de 5 A.




Accuenergy AcuCT-2031-600:1 Split Core Current Transformer, 0.83 x 1.22", 600 A:1 A AcuCT-2031-600:1
Split core current transformer features a window size of 1.97 x 3.15quot;, current input of 600 A and output of 1 A.




Accuenergy AcuCT-2031-600:5 Transformateur de courant à noyau fendu, 21 x 31 mm, 600 A:5 A AcuCT-2031-600:5
Le transformateur de courant à noyau divisé présente une fenêtre de 50 x 80 mm, une entrée de courant de 600 A et une sortie de 5 A.




Accuenergy AcuCT-2031-800:1 Split Core Current Transformer, 0.83 x 1.22", 800 A:1 A AcuCT-2031-800:1
Split core current transformer features a window size of 1.97 x 3.15quot;, current input of 800 A and output of 1 A.




Accuenergy AcuCT-2031-800:5 Split Core Current Transformer, 0.83 x 1.22", 800 A:5 A AcuCT-2031-800:5
Split core current transformer features a window size of 1.97 x 3.15quot;, current input of 800 A and output of 5 A.




Accuenergy AcuCT-2031-1000:1 Split Core Current Transformer, 0.83 x 1.22", 1000 A:1 A AcuCT-2031-1000:1
Split core current transformer features a window size of 1.97 x 3.15", current input of 1000 A and output of 1 A.




Accuenergy AcuCT-3147-1000:1 Split Core Current Transformer, 3.15 x 4.72", 1000 A:1 A AcuCT-3147-1000:1
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1000 A and output of 1 A.




Accuenergy AcuCT-2031-1000:5 Split Core Current Transformer, 0.83 x 1.22", 1000 A:5 A AcuCT-2031-1000:5
Split core current transformer features a window size of 1.97 x 3.15quot;, current input of 1000 A and output of 5 A.




Accuenergy AcuCT-3147-1000:5 Split Core Current Transformer, 3.15 x 4.72", 1000 A:5 A AcuCT-3147-1000:5
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1000 A and output of 5 A.




Accuenergy AcuCT-3147-1200:1 Split Core Current Transformer, 3.15 x 4.72", 1200 A:1 A AcuCT-3147-1200:1
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1200 A and output of 1 A.




Accuenergy AcuCT-3147-1200:5 Split Core Current Transformer,3.15 x 4.72quot;, 1200 A:5 A AcuCT-3147-1200:5
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1200 A and output of 5 A.




Accuenergy AcuCT-3147-1600:1 Split Core Current Transformer, 3.15 x 4.72", 1600 A:1 A AcuCT-3147-1600:1
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1600 A and output of 1 A.




Accuenergy AcuCT-3147-1600:5 Split Core Current Transformer,3.15 x 4.72quot;, 1600 A:5 A AcuCT-3147-1600:5
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1600 A and output of 5 A.




Accuenergy AcuCT-3163-2000:1 Split Core Current Transformer, 3.15 x 6.3", 2000 A:1 A AcuCT-3163-2000:1
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 2000 A and output of 1 A.




Accuenergy AcuCT-3163-2000:5 Split Core Current Transformer,3.15 x 6.3quot;, 2000 A:5 A AcuCT-3163-2000:5
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 2000 A and output of 5 A.




Accuenergy AcuCT-3163-2500:1 Split Core Current Transformer, 3.15 x 6.3", 2500 A:1 A AcuCT-3163-2500:1
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 2500 A and output of 1 A.




Accuenergy AcuCT-3163-2500:5 Split Core Current Transformer,3.15 x 6.3quot;, 2500 A:5 A AcuCT-3163-2500:5
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 2500 A and output of 5 A.




Accuenergy AcuCT-3163-3000:1 Split Core Current Transformer, 3.15 x 6.3", 3000 A:1 A AcuCT-3163-3000:1
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 3000 A and output of 1 A.




Accuenergy AcuCT-3163-3000:5 Split Core Current Transformer,3.15 x 6.3quot;, 3000 A:5 A AcuCT-3163-3000:5
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 3000 A and output of 5 A.




Accuenergy AcuCT-3163-4000:1 Split Core Current Transformer, 3.15 x 6.3", 4000 A:1 A AcuCT-3163-4000:1
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 4000 A and output of 1 A.




Accuenergy AcuCT-3163-4000:5 Split Core Current Transformer,3.15 x 6.3quot;, 4000 A:5 A AcuCT-3163-4000:5
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 4000 A and output of 5 A.




Accuenergy AcuCT-3163-5000:1 Split Core Current Transformer, 3.15 x 6.3", 5000 A:1 A AcuCT-3163-5000:1
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 5000 A and output of 1 A.




Accuenergy AcuCT-3163-5000:5 Split Core Current Transformer,3.15 x 6.3quot;, 5000 A:5 A AcuCT-3163-5000:5
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 5000 A and output of 5 A.




Accuenergy AcuCT-0812-100:1 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 100 A:1 A AcuCT-0812-100:1
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 100 A et une sortie de 1 A.




Accuenergy AcuCT-0812-100:5 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 100 A:5 A AcuCT-0812-100:5
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 100 A et une sortie de 5 A.




Poser une question sur le Accuenergy AcuRev 1314-5A-X1 DIN Rail Power/Energy Meter, 5 A/1 A CT input, relay output

Spécifications pour le Accuenergy AcuRev-1314-5A-X1

Parameter AccuracyResolutionRange
Active Energy 0.50%1Wh0 to 999999999kWh
Reactive Energy 0.50%1varh0 to 999999999kvarh
Apparent Energy 0.50%1VAh0 to 999999999kVAh
Voltage 0.50%0.110V to 1000KV
Current 0.50%0.001A10mA to 500000A
Active Power 0.50%1W-99 to 99MW
Reactive Power 0.50%1var-99 to 99Mvar
Apparent Power 0.50%1VA-99 to 99MVA
Power Factor 0.50%0.001-1.000 to 1.000
Frequency 0.20%0.01Hz50/60Hz
Power Demand 0.50%1W/var/VA99MW/Mvar/MVA
Current Demand 0.50%0.001A10mA to 5000A

Le Accuenergy AcuRev-1314-5A-X1 comprend

  • Accuenergy AcuRev 1314-5A-X1 DIN Rail Power/Energy Meter, 5 A/1 A CT input, relay output

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Accuenergy AcuRev 1314-5A-X1 DIN Rail Power/Energy Meter, 5 A/1 A CT input, relay output.

Accuenergy AcuCT-0812-200:5 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 200 A:5 A AcuCT-0812-200:5
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 200 A et une sortie de 5 A.




Accuenergy AcuCT-0812-200:1 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 200 A:1 A AcuCT-0812-200:1
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 200 A et une sortie de 1 A.




Accuenergy AcuCT-0812-250:1 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 250 A:1 A AcuCT-0812-250:1
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 250 A et une sortie de 1 A.




Accuenergy AcuCT-0812-250:5 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 250 A:5 A AcuCT-0812-250:5
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 250 A et une sortie de 5 A.




Accuenergy AcuCT-0812-300:1 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 300 A:1 A AcuCT-0812-300:1
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 300 A et une sortie de 1 A.




Accuenergy AcuCT-0812-300:5 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 300 A:5 A AcuCT-0812-300:5
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 300 A et une sortie de 5 A.




Accuenergy AcuCT-0812-400:1 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 400 A:1 A AcuCT-0812-400:1
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 400 A et une sortie de 1 A.




Accuenergy AcuCT-2031-400:1 Split Core Current Transformer, 0.83 x 1.22", 400 A:1 A AcuCT-2031-400:1
Split core current transformer features a window size of 1.97 x 3.15quot;, current input of 400 A and output of 1 A.




Accuenergy AcuCT-2031-400:5 Transformateur de courant à noyau divisé, 0.83 x 1.22", 400 A: 5 A AcuCT-2031-400:5
Transformateur de courant à noyau fendu, avec fenêtre de 50 x 80 mm, entrée de courant de 400 A et sortie de 5 A.




Accuenergy AcuCT-0812-400:5 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 400 A:5 A AcuCT-0812-400:5
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 400 A et une sortie de 5 A.




Accuenergy AcuCT-2031-600:1 Split Core Current Transformer, 0.83 x 1.22", 600 A:1 A AcuCT-2031-600:1
Split core current transformer features a window size of 1.97 x 3.15quot;, current input of 600 A and output of 1 A.




Accuenergy AcuCT-2031-600:5 Transformateur de courant à noyau fendu, 21 x 31 mm, 600 A:5 A AcuCT-2031-600:5
Le transformateur de courant à noyau divisé présente une fenêtre de 50 x 80 mm, une entrée de courant de 600 A et une sortie de 5 A.




Accuenergy AcuCT-2031-800:1 Split Core Current Transformer, 0.83 x 1.22", 800 A:1 A AcuCT-2031-800:1
Split core current transformer features a window size of 1.97 x 3.15quot;, current input of 800 A and output of 1 A.




Accuenergy AcuCT-2031-800:5 Split Core Current Transformer, 0.83 x 1.22", 800 A:5 A AcuCT-2031-800:5
Split core current transformer features a window size of 1.97 x 3.15quot;, current input of 800 A and output of 5 A.




Accuenergy AcuCT-2031-1000:1 Split Core Current Transformer, 0.83 x 1.22", 1000 A:1 A AcuCT-2031-1000:1
Split core current transformer features a window size of 1.97 x 3.15", current input of 1000 A and output of 1 A.




Accuenergy AcuCT-3147-1000:1 Split Core Current Transformer, 3.15 x 4.72", 1000 A:1 A AcuCT-3147-1000:1
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1000 A and output of 1 A.




Accuenergy AcuCT-2031-1000:5 Split Core Current Transformer, 0.83 x 1.22", 1000 A:5 A AcuCT-2031-1000:5
Split core current transformer features a window size of 1.97 x 3.15quot;, current input of 1000 A and output of 5 A.




Accuenergy AcuCT-3147-1000:5 Split Core Current Transformer, 3.15 x 4.72", 1000 A:5 A AcuCT-3147-1000:5
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1000 A and output of 5 A.




Accuenergy AcuCT-3147-1200:1 Split Core Current Transformer, 3.15 x 4.72", 1200 A:1 A AcuCT-3147-1200:1
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1200 A and output of 1 A.




Accuenergy AcuCT-3147-1200:5 Split Core Current Transformer,3.15 x 4.72quot;, 1200 A:5 A AcuCT-3147-1200:5
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1200 A and output of 5 A.




Accuenergy AcuCT-3147-1600:1 Split Core Current Transformer, 3.15 x 4.72", 1600 A:1 A AcuCT-3147-1600:1
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1600 A and output of 1 A.




Accuenergy AcuCT-3147-1600:5 Split Core Current Transformer,3.15 x 4.72quot;, 1600 A:5 A AcuCT-3147-1600:5
Split core current transformer features a window size of 3.15 x 4.72quot;, current input of 1600 A and output of 5 A.




Accuenergy AcuCT-3163-2000:1 Split Core Current Transformer, 3.15 x 6.3", 2000 A:1 A AcuCT-3163-2000:1
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 2000 A and output of 1 A.




Accuenergy AcuCT-3163-2000:5 Split Core Current Transformer,3.15 x 6.3quot;, 2000 A:5 A AcuCT-3163-2000:5
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 2000 A and output of 5 A.




Accuenergy AcuCT-3163-2500:1 Split Core Current Transformer, 3.15 x 6.3", 2500 A:1 A AcuCT-3163-2500:1
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 2500 A and output of 1 A.




Accuenergy AcuCT-3163-2500:5 Split Core Current Transformer,3.15 x 6.3quot;, 2500 A:5 A AcuCT-3163-2500:5
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 2500 A and output of 5 A.




Accuenergy AcuCT-3163-3000:1 Split Core Current Transformer, 3.15 x 6.3", 3000 A:1 A AcuCT-3163-3000:1
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 3000 A and output of 1 A.




Accuenergy AcuCT-3163-3000:5 Split Core Current Transformer,3.15 x 6.3quot;, 3000 A:5 A AcuCT-3163-3000:5
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 3000 A and output of 5 A.




Accuenergy AcuCT-3163-4000:1 Split Core Current Transformer, 3.15 x 6.3", 4000 A:1 A AcuCT-3163-4000:1
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 4000 A and output of 1 A.




Accuenergy AcuCT-3163-4000:5 Split Core Current Transformer,3.15 x 6.3quot;, 4000 A:5 A AcuCT-3163-4000:5
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 4000 A and output of 5 A.




Accuenergy AcuCT-3163-5000:1 Split Core Current Transformer, 3.15 x 6.3", 5000 A:1 A AcuCT-3163-5000:1
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 5000 A and output of 1 A.




Accuenergy AcuCT-3163-5000:5 Split Core Current Transformer,3.15 x 6.3quot;, 5000 A:5 A AcuCT-3163-5000:5
Split core current transformer features a window size of 3.15 x 6.3quot;, current input of 5000 A and output of 5 A.




Accuenergy AcuCT-0812-100:1 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 100 A:1 A AcuCT-0812-100:1
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 100 A et une sortie de 1 A.




Accuenergy AcuCT-0812-100:5 Transformateur de courant à circuit magnétique ouvrant, 0.83 x 1.22 po, 100 A:5 A AcuCT-0812-100:5
Transformateur de courant à circuit magnétique ouvrant est caractérisés par des dimensions de 0.83 x 1.22 po, une entrée de courant de 100 A et une sortie de 5 A.




Poser une question sur le Accuenergy AcuRev 1314-5A-X1 DIN Rail Power/Energy Meter, 5 A/1 A CT input, relay output

Plus de produits Accuenergy