Accuenergy AcuPRE-WM-04-A-2 Wall Mount Differential Pressure Sensor with display, ±1% FS accuracy, -0.125 to 0.125, and -0.25 to 0.25", 0 to 5 V DC

Modèle: AcuPRE-WM-04-A-2

Accuenergy AcuPRE-WM-04-A-2 Wall Mount Differential Pressure Sensor with display, ±1% FS accuracy, -0.125 to 0.125, and -0.25 to 0.25", 0 to 5 V DC

Modèle: AcuPRE-WM-04-A-2

Buit for monitoring localized spaces, this highly accurate MEMS sensor features static pressure ports. In addition, it measures positive, negative, or differential pressure (DP) ranges from -0.125 to 0.125, and -0.25 to 0.25 bidirectional inWC, with a 0-5 V DC output system integration.

Buit for monitoring localized spaces, this highly accurate MEMS sensor features static pressure ports. In addition, it measures positive, negative, or differential pressure (DP) ranges from -0.125 to 0.125, and -0.25 to 0.25 bidirectional inWC, with a 0-5 V DC output system integration.

Prix spécial $209.48 CAD
Prix régulier $220.50 CAD
Disponibilité 2 à 3 semaines
Quantité

Accuenergy AcuPRE-WM-04-A-2 offre

A wall mount DP sensor is a device that is most suited for localized spaces or environments that measure the difference in pressure between two points in a system, providing a reading of the pressure difference between the positive and negative space. Pressure sensors are widely used for monitoring compartmentalized spaces such as clean rooms, laboratories, and medical centers. The AcuPRE WM series can easily be surface mounted on any flat surface.

Designed for accurate pressure measurement in localized spaces, the AcuPRE WM series differential pressure sensor is suitable for wall mount installations with minimum surface exposure. It employs a high-accuracy MEMS sensor to measure positive, negative, and differential pressure (DP) to monitor airflow, building or room pressure, or indicate when filters need to be replaced. The DP sensor features configurable settings, including zero calibration, pressure range, response time, and unit of measurement. The AcuPRE WM sensor includes a 4-digit LCD that aids in troubleshooting and installation.

Quick to setup, the AcuPRE WM wall mount DP sensor is easy to clean and maintain, making it perfect for local environments where air pressure control and hygiene are critical. The AcuPRE WM DP sensors deliver accurate real-time data on the air pressure condition at all times. It can be used to measure fans, filters in laboratories, clean bench, and medical equipment.

Caractéristiques

  • ±1.0% full range accuracy ensuring precise measurements
  • Designed for wall/surface mount applications
  • Field selectable ranges as low as 0 to 0.1 to 0 to 40 inWC based on model number selection
  • Unidirectional or bidirectional measurements
  • User selectable response time: 0.5/1/2/5 seconds
  • User selectable units of measurementwith DIP switches allowing quick unit conversion
  • All models come with 4-digit LCD display
  • IP 65 rated water-resistant and UL94V-0 fire retardant enclosure
  • Easy zero calibration to remove offset errors

Applications

  • Localized installation

Spécifications pour le Accuenergy AcuPRE-WM-04-A-2

Electrical
Voltage Power V AC: 16 to 28
V DC: 16 to 35
Current Power V DC: 18.5 to 35 (RL = 500 Ω)
V DC: 8.5 to 35 (RL = 0 Ω)
Output 0–5 V DC
Output Load Current: ≤500 Ω
Voltage: ≥2 kΩ
Environmental
Medium Non-combustible
Non-corrosive air

Temperature range: 32 to 140°F (0 to 60°C)
Temperature Operating range: -4 to 158°F (-20 to 70°C)
Compensation: 32 to 122°F (0 to 50°C)
Working Pressure Overload: 10×FS
Burst: 15×FS
Mechanical
Mounting 2-screw surface mount with hinged cover
Connection 0.19" (5 mm) ID tubing
High/Low pressure ports
Weight 0.36 lbs (165 g)
Display 4-digit LCD
Size: 2.56 x 0.70" (65 x 18 mm), with unit indication
Performance
Accuracy ±1.0% FS (±2.0% FS at 0.10 inWC Range)
Stability ±0.5% FS/year
Thermal Effect ±0.045% FS/°F (FS) (<0.08% FS/°C)
Response Time 0.5 / 1 / 2 / 5 seconds (can be set by DIP switches)
Certifications
Enclosure Material ABS+PC (housing) and PC (cover)
Fire retardant UL94V-0
Protection IP65
Agency Approvals CE

Le Accuenergy AcuPRE-WM-04-A-2 comprend

  • Sensor
  • Five-Year Warranty

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Accuenergy AcuPRE-WM-04-A-2 Wall Mount Differential Pressure Sensor with display, ±1% FS accuracy, -0.125 to 0.125, and -0.25 to 0.25", 0 to 5 V DC.

Accuenergy AcuPRE-XX-001 Tube en PVC transparent, 2 m AcuPRE-XX-001
Le tube en PVC transparent est utilisé pour transmettre la pression d'air aux capteurs et est conçu pour être compatible avec tous les capteurs de pression différentielle AcuPRE. Il est disponible en longueurs de 2 m (6.5') et 100 m (330'), ce qui le rend adapté à une variété de conditions d'installation.




Accuenergy AcuPRE-XX-002 Tube en PVC transparent, 100 m AcuPRE-XX-002
Le tube en PVC transparent est utilisé pour transmettre la pression d'air aux capteurs et est conçu pour être compatible avec tous les capteurs de pression différentielle AcuPRE. Il est disponible en longueurs de 2 m (6.5') et 100 m (330'), ce qui le rend adapté à une variété de conditions d'installation.




Accuenergy AcuPRE-XX-009 Prise de pression ambiante AcuPRE-XX-009
Les prises de pression sont des orifices d'entrée connectés à des capteurs de pression différentielle, leur permettant d'échantillonner la pression d'air tout en empêchant les grosses particules de pénétrer et d'endommager potentiellement le capteur. Ce modèle est le modèle de base pour la pression ambiante.




Accuenergy AcuPRE-XX-010 Prise de pression murale en acier inoxydable AcuPRE-XX-010
Les prises de pression sont des orifices d'entrée connectés à des capteurs de pression différentielle, leur permettant d'échantillonner la pression d'air tout en empêchant les grosses particules de pénétrer et d'endommager potentiellement le capteur. Ce modèle est la configuration de prise de pression sur plaque murale en acier inoxydable.




Accuenergy AcuPRE-XX-008 Capteur de pression statique, type L, 304SS, ouverture 0°, 6 x 200 mm AcuPRE-XX-008
Les capteurs de pression sont utilisés pour mesurer la pression d'air dans les systèmes CVC/R et sont conçus pour être compatibles avec les capteurs DP AcuPRE. Ils sont offerts en version droite ou de type L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Pris en charge pour la pression statique et totale, assurant des mesures de pression fiables dans les environnements exigeants.




Accuenergy AcuPRE-XX-007 Capteur de pression statique, type L, 304SS, ouverture 0°, 6 x 125 mm AcuPRE-XX-007
Les capteurs de pression sont utilisés pour mesurer la pression d'air dans les systèmes CVC/R et sont conçus pour être compatibles avec les capteurs DP AcuPRE. Ils sont offerts en version droite ou de type L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Pris en charge pour la pression statique et totale, assurant des mesures de pression fiables dans les environnements exigeants.




Accuenergy AcuPRE-XX-006 Capteur de pression statique, type droit, 304SS, ouverture 0°, 6 x 200 mm AcuPRE-XX-006
Les capteurs de pression sont utilisés pour mesurer la pression d'air dans les systèmes CVC/R et sont conçus pour être compatibles avec les capteurs DP AcuPRE. Ils sont offerts en version droite ou en L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Pris en charge pour la pression statique et totale, assurant des mesures de pression fiables dans les environnements exigeants.




Accuenergy AcuPRE-XX-005 Sonde de pression statique, type droit, 304SS, ouverture 0°, 6 x 125 mm AcuPRE-XX-005
Les sondes de pression sont utilisées pour mesurer la pression d'air dans les systèmes CVC/R et sont conçues pour être compatibles avec les capteurs de pression différentielle AcuPRE. Elles sont offertes en type droit ou en L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Prises en charge pour la pression statique et totale, elles assurent des mesures de pression fiables dans les environnements exigeants.




Accuenergy AcuPRE-XX-004 Embout de pression totale, type droit, ABS, ouverture 60°, 4 x 6.55 x 77.5 mm AcuPRE-XX-004
Les embouts de pression sont utilisés pour mesurer la pression d'air dans les systèmes CVC/R et sont conçus pour être compatibles avec les capteurs DP AcuPRE. Ils sont disponibles en type droit ou en L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Pris en charge pour la pression statique et totale, assurant des mesures de pression fiables dans les environnements exigeants.




Accuenergy AcuPRE-XX-003 Embout de pression statique, type droit, ABS, ouverture 0°, 4 x 6.55 x 77.5 mm AcuPRE-XX-003
Les embouts de pression sont utilisés pour mesurer la pression d'air dans les systèmes CVC/R et sont conçus pour être compatibles avec les capteurs DP AcuPRE. Ils sont disponibles en type droit ou en L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Pris en charge pour la pression statique et totale, assurant des mesures de pression fiables dans les environnements exigeants.




Poser une question sur le Accuenergy AcuPRE-WM-04-A-2 Wall Mount Differential Pressure Sensor with display, ±1% FS accuracy, -0.125 to 0.125, and -0.25 to 0.25", 0 to 5 V DC

Accuenergy AcuPRE-WM-04-A-2 offre

A wall mount DP sensor is a device that is most suited for localized spaces or environments that measure the difference in pressure between two points in a system, providing a reading of the pressure difference between the positive and negative space. Pressure sensors are widely used for monitoring compartmentalized spaces such as clean rooms, laboratories, and medical centers. The AcuPRE WM series can easily be surface mounted on any flat surface.

Designed for accurate pressure measurement in localized spaces, the AcuPRE WM series differential pressure sensor is suitable for wall mount installations with minimum surface exposure. It employs a high-accuracy MEMS sensor to measure positive, negative, and differential pressure (DP) to monitor airflow, building or room pressure, or indicate when filters need to be replaced. The DP sensor features configurable settings, including zero calibration, pressure range, response time, and unit of measurement. The AcuPRE WM sensor includes a 4-digit LCD that aids in troubleshooting and installation.

Quick to setup, the AcuPRE WM wall mount DP sensor is easy to clean and maintain, making it perfect for local environments where air pressure control and hygiene are critical. The AcuPRE WM DP sensors deliver accurate real-time data on the air pressure condition at all times. It can be used to measure fans, filters in laboratories, clean bench, and medical equipment.

Caractéristiques

  • ±1.0% full range accuracy ensuring precise measurements
  • Designed for wall/surface mount applications
  • Field selectable ranges as low as 0 to 0.1 to 0 to 40 inWC based on model number selection
  • Unidirectional or bidirectional measurements
  • User selectable response time: 0.5/1/2/5 seconds
  • User selectable units of measurementwith DIP switches allowing quick unit conversion
  • All models come with 4-digit LCD display
  • IP 65 rated water-resistant and UL94V-0 fire retardant enclosure
  • Easy zero calibration to remove offset errors

Applications

  • Localized installation

Spécifications pour le Accuenergy AcuPRE-WM-04-A-2

Electrical
Voltage Power V AC: 16 to 28
V DC: 16 to 35
Current Power V DC: 18.5 to 35 (RL = 500 Ω)
V DC: 8.5 to 35 (RL = 0 Ω)
Output 0–5 V DC
Output Load Current: ≤500 Ω
Voltage: ≥2 kΩ
Environmental
Medium Non-combustible
Non-corrosive air

Temperature range: 32 to 140°F (0 to 60°C)
Temperature Operating range: -4 to 158°F (-20 to 70°C)
Compensation: 32 to 122°F (0 to 50°C)
Working Pressure Overload: 10×FS
Burst: 15×FS
Mechanical
Mounting 2-screw surface mount with hinged cover
Connection 0.19" (5 mm) ID tubing
High/Low pressure ports
Weight 0.36 lbs (165 g)
Display 4-digit LCD
Size: 2.56 x 0.70" (65 x 18 mm), with unit indication
Performance
Accuracy ±1.0% FS (±2.0% FS at 0.10 inWC Range)
Stability ±0.5% FS/year
Thermal Effect ±0.045% FS/°F (FS) (<0.08% FS/°C)
Response Time 0.5 / 1 / 2 / 5 seconds (can be set by DIP switches)
Certifications
Enclosure Material ABS+PC (housing) and PC (cover)
Fire retardant UL94V-0
Protection IP65
Agency Approvals CE

Le Accuenergy AcuPRE-WM-04-A-2 comprend

  • Sensor
  • Five-Year Warranty

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Accuenergy AcuPRE-WM-04-A-2 Wall Mount Differential Pressure Sensor with display, ±1% FS accuracy, -0.125 to 0.125, and -0.25 to 0.25", 0 to 5 V DC.

Accuenergy AcuPRE-XX-001 Tube en PVC transparent, 2 m AcuPRE-XX-001
Le tube en PVC transparent est utilisé pour transmettre la pression d'air aux capteurs et est conçu pour être compatible avec tous les capteurs de pression différentielle AcuPRE. Il est disponible en longueurs de 2 m (6.5') et 100 m (330'), ce qui le rend adapté à une variété de conditions d'installation.




Accuenergy AcuPRE-XX-002 Tube en PVC transparent, 100 m AcuPRE-XX-002
Le tube en PVC transparent est utilisé pour transmettre la pression d'air aux capteurs et est conçu pour être compatible avec tous les capteurs de pression différentielle AcuPRE. Il est disponible en longueurs de 2 m (6.5') et 100 m (330'), ce qui le rend adapté à une variété de conditions d'installation.




Accuenergy AcuPRE-XX-009 Prise de pression ambiante AcuPRE-XX-009
Les prises de pression sont des orifices d'entrée connectés à des capteurs de pression différentielle, leur permettant d'échantillonner la pression d'air tout en empêchant les grosses particules de pénétrer et d'endommager potentiellement le capteur. Ce modèle est le modèle de base pour la pression ambiante.




Accuenergy AcuPRE-XX-010 Prise de pression murale en acier inoxydable AcuPRE-XX-010
Les prises de pression sont des orifices d'entrée connectés à des capteurs de pression différentielle, leur permettant d'échantillonner la pression d'air tout en empêchant les grosses particules de pénétrer et d'endommager potentiellement le capteur. Ce modèle est la configuration de prise de pression sur plaque murale en acier inoxydable.




Accuenergy AcuPRE-XX-008 Capteur de pression statique, type L, 304SS, ouverture 0°, 6 x 200 mm AcuPRE-XX-008
Les capteurs de pression sont utilisés pour mesurer la pression d'air dans les systèmes CVC/R et sont conçus pour être compatibles avec les capteurs DP AcuPRE. Ils sont offerts en version droite ou de type L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Pris en charge pour la pression statique et totale, assurant des mesures de pression fiables dans les environnements exigeants.




Accuenergy AcuPRE-XX-007 Capteur de pression statique, type L, 304SS, ouverture 0°, 6 x 125 mm AcuPRE-XX-007
Les capteurs de pression sont utilisés pour mesurer la pression d'air dans les systèmes CVC/R et sont conçus pour être compatibles avec les capteurs DP AcuPRE. Ils sont offerts en version droite ou de type L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Pris en charge pour la pression statique et totale, assurant des mesures de pression fiables dans les environnements exigeants.




Accuenergy AcuPRE-XX-006 Capteur de pression statique, type droit, 304SS, ouverture 0°, 6 x 200 mm AcuPRE-XX-006
Les capteurs de pression sont utilisés pour mesurer la pression d'air dans les systèmes CVC/R et sont conçus pour être compatibles avec les capteurs DP AcuPRE. Ils sont offerts en version droite ou en L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Pris en charge pour la pression statique et totale, assurant des mesures de pression fiables dans les environnements exigeants.




Accuenergy AcuPRE-XX-005 Sonde de pression statique, type droit, 304SS, ouverture 0°, 6 x 125 mm AcuPRE-XX-005
Les sondes de pression sont utilisées pour mesurer la pression d'air dans les systèmes CVC/R et sont conçues pour être compatibles avec les capteurs de pression différentielle AcuPRE. Elles sont offertes en type droit ou en L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Prises en charge pour la pression statique et totale, elles assurent des mesures de pression fiables dans les environnements exigeants.




Accuenergy AcuPRE-XX-004 Embout de pression totale, type droit, ABS, ouverture 60°, 4 x 6.55 x 77.5 mm AcuPRE-XX-004
Les embouts de pression sont utilisés pour mesurer la pression d'air dans les systèmes CVC/R et sont conçus pour être compatibles avec les capteurs DP AcuPRE. Ils sont disponibles en type droit ou en L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Pris en charge pour la pression statique et totale, assurant des mesures de pression fiables dans les environnements exigeants.




Accuenergy AcuPRE-XX-003 Embout de pression statique, type droit, ABS, ouverture 0°, 4 x 6.55 x 77.5 mm AcuPRE-XX-003
Les embouts de pression sont utilisés pour mesurer la pression d'air dans les systèmes CVC/R et sont conçus pour être compatibles avec les capteurs DP AcuPRE. Ils sont disponibles en type droit ou en L, avec des ouvertures d'angle de 0° ou 60°, en acier inoxydable ou en ABS. Pris en charge pour la pression statique et totale, assurant des mesures de pression fiables dans les environnements exigeants.




Poser une question sur le Accuenergy AcuPRE-WM-04-A-2 Wall Mount Differential Pressure Sensor with display, ±1% FS accuracy, -0.125 to 0.125, and -0.25 to 0.25", 0 to 5 V DC

Plus de produits Accuenergy