Accuenergy AcuCT 333 mV Series 333mV Split Core Current Transformers

Accuenergy AcuCT 333 mV Series 333mV Split Core Current Transformers

Sélection de modèles

SPÉCIAL! Accuenergy AcuCT-125-400:333 Split Core Current Transformer, 1.25 x 1.25", 400 A:333 mV
AcuCT-125-400:333 $66.97 CAD
Était: $70.50
Disponibilité:
1 à 2 semaines
Accuenergy AcuCT-125-600:333 Split Core Current Transformer, 1.25 x 1.25", 600 A:333 mV
AcuCT-125-600:333 $66.97 CAD
Était: $70.50
Disponibilité:
1 à 2 semaines

Compact and lightweight line of conventional split core 333 mV current transformers are designed for panel and device monitoring use without disconnecting cables.

Compact and lightweight line of conventional split core 333 mV current transformers are designed for panel and device monitoring use without disconnecting cables.

SPÉCIAL! Accuenergy AcuCT-125-400:333 Split Core Current Transformer, 1.25 x 1.25", 400 A:333 mV
AcuCT-125-400:333 $66.97 CAD
Était: $70.50
Disponibilité:
1 à 2 semaines
Accuenergy AcuCT-125-600:333 Split Core Current Transformer, 1.25 x 1.25", 600 A:333 mV
AcuCT-125-600:333 $66.97 CAD
Était: $70.50
Disponibilité:
1 à 2 semaines

Accuenergy AcuCT 333mV Series offre

These split core CTs permit quick and easy installation without disconnecting cables and are ideal for low cost energy efficiency and energy management systems.

Caractéristiques

  • Conventional 333 mV split-core style CT
  • Available in a variety of sizes and current input ranges from 20A to 5000A AC
  • 0.5% accuracy from 10 to 120% of rated current
  • Internal precision burden resistor across the secondary winding of the CT provides a safe low voltage output
  • Permits safe opening of the secondary
  • UL recognized

Spécifications pour le Accuenergy AcuCT 333mV Series

Input Ranges 10A to 200A
30A to 600A
60A to 1500A
40A to 5000A
Rated Option 333mV
Window Sizes 0.75 x 0.75" (19.1 x 19.1mm)
1.25 x 1.25" (31.8 x 31.8mm)
2 x 2" (50.8 x 50.8mm)
3 x 5" (76.2 x 127mm)
Exterior Dimensions 2 x 2.098 x 0.669" (50.8 x 53.3 x 17mm)
3.248 x 3.35 x 1.024" (82.5 x 85.1 x 26mm)
4.764 x 5 x 1.181" (121 x 127 x 30mm)
5.748 x 7.5 x 1.402" (146 x 190.5 x 35.6mm)
Accuracy 0.5%
Standard/Certifications UR, CE, RoHS
Form Factor Square Split Core or Rectangle Split Core

Le Accuenergy AcuCT 333mV Series comprend

  • Accuenergy AcuCT 333 mV Series 333mV Split Core Current Transformers

Poser une question sur le Accuenergy AcuCT 333 mV Series 333mV Split Core Current Transformers

Accuenergy AcuCT 333mV Series offre

These split core CTs permit quick and easy installation without disconnecting cables and are ideal for low cost energy efficiency and energy management systems.

Caractéristiques

  • Conventional 333 mV split-core style CT
  • Available in a variety of sizes and current input ranges from 20A to 5000A AC
  • 0.5% accuracy from 10 to 120% of rated current
  • Internal precision burden resistor across the secondary winding of the CT provides a safe low voltage output
  • Permits safe opening of the secondary
  • UL recognized

Spécifications pour le Accuenergy AcuCT 333mV Series

Input Ranges 10A to 200A
30A to 600A
60A to 1500A
40A to 5000A
Rated Option 333mV
Window Sizes 0.75 x 0.75" (19.1 x 19.1mm)
1.25 x 1.25" (31.8 x 31.8mm)
2 x 2" (50.8 x 50.8mm)
3 x 5" (76.2 x 127mm)
Exterior Dimensions 2 x 2.098 x 0.669" (50.8 x 53.3 x 17mm)
3.248 x 3.35 x 1.024" (82.5 x 85.1 x 26mm)
4.764 x 5 x 1.181" (121 x 127 x 30mm)
5.748 x 7.5 x 1.402" (146 x 190.5 x 35.6mm)
Accuracy 0.5%
Standard/Certifications UR, CE, RoHS
Form Factor Square Split Core or Rectangle Split Core

Le Accuenergy AcuCT 333mV Series comprend

  • Accuenergy AcuCT 333 mV Series 333mV Split Core Current Transformers

Poser une question sur le Accuenergy AcuCT 333 mV Series 333mV Split Core Current Transformers

Plus de produits Accuenergy