AMETEK Crystal 4013 Quick Test NPT Kit

Modèle: 4013

AMETEK Crystal 4013 Quick Test NPT Kit

Modèle: 4013

Includes the MPF-1/8QTF, MPF-1/4QTF, and MPF-1/2QTF quick test females fittings.

Includes the MPF-1/8QTF, MPF-1/4QTF, and MPF-1/2QTF quick test females fittings.

Votre prix $705.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Crystal Pressure 4013 Offers

CPF is an improved cone type fitting system that adds a unique o-ring sealing system which permits leak free connections without tools.  CPF fittings can be directly connected to 1/4" medium pressure cone type fittings from other manufacturers*, provided that wrenches are used to complete the connection.  The fittings of the CPF system have been designed and tested to comply with ASME B31.3-2008, Chapter IX: High Pressure Piping.

* HiP: 1/4" Female and Male Medium Pressure (LF4 & LM4 series)

Autoclave Engineers: 1/4" Female and Male Medium Pressure (SF250CX series)

Notes:
Non-Crystal MP adapters require wrench tightening
Hose is not compatible with dioctyl sebacate fluid
CAUTION: To achieve CPF maximum allowable working pressures no o-ring substitutions are allowed.
If a torque wrench isn't practical to use, hand tighten then tighten an additional 20 degrees using a wrench.
 


Le Crystal Pressure 4013 comprend

  • AMETEK Crystal 4013 Quick Test NPT Kit

Poser une question sur le AMETEK Crystal 4013 Quick Test NPT Kit

Crystal Pressure 4013 Offers

CPF is an improved cone type fitting system that adds a unique o-ring sealing system which permits leak free connections without tools.  CPF fittings can be directly connected to 1/4" medium pressure cone type fittings from other manufacturers*, provided that wrenches are used to complete the connection.  The fittings of the CPF system have been designed and tested to comply with ASME B31.3-2008, Chapter IX: High Pressure Piping.

* HiP: 1/4" Female and Male Medium Pressure (LF4 & LM4 series)

Autoclave Engineers: 1/4" Female and Male Medium Pressure (SF250CX series)

Notes:
Non-Crystal MP adapters require wrench tightening
Hose is not compatible with dioctyl sebacate fluid
CAUTION: To achieve CPF maximum allowable working pressures no o-ring substitutions are allowed.
If a torque wrench isn't practical to use, hand tighten then tighten an additional 20 degrees using a wrench.
 


Le Crystal Pressure 4013 comprend

  • AMETEK Crystal 4013 Quick Test NPT Kit

Poser une question sur le AMETEK Crystal 4013 Quick Test NPT Kit

Plus de produits Crystal Pressure