Trumeter APM-VT-PWR-HV-D345 Guardian Power and Protective Conductor Monitoring with visual display of alerts and status

Modèle: APM-VT-PWR-HV-D345 | CUP: 5061089360046

Trumeter APM-VT-PWR-HV-D345 Guardian Power and Protective Conductor Monitoring with visual display of alerts and status

Modèle: APM-VT-PWR-HV-D345 | CUP: 5061089360046

Ensure maximum electrical safety and prevent equipment damage with this advanced line-tracking module. It provides clear, immediate feedback on circuit integrity and potential faults, keeping operators informed and high-voltage manufacturing systems running securely.

Ensure maximum electrical safety and prevent equipment damage with this advanced line-tracking module. It provides clear, immediate feedback on circuit integrity and potential faults, keeping operators informed and high-voltage manufacturing systems running securely.

Prix spécial $2215.59 CAD
Prix régulier $2622.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Trumeter APM-VT-PWR-HV-D345 offre

The Guardian is an advanced power and protective conductor monitoring system, designed to detect and safeguard electrical systems against broken neutral faults and stray voltages on connected services. It continuously monitors the electricity supply and electrical infrastructure, with the capability to isolate or alert any detected faults, including loss of neutral, broken PEN conductors, voltage on protective earth/ground conductors, high and low line voltages and frequencies.

Incorporating patented O-PEN® technology from matt:e, a leading expert in broken neutral and PEN fault protection products, the Guardian provides comprehensive protection to assets and people, including cloud-based real-time monitoring with matt:e cloud, with SMS and email alerts for potential failures.

The Guardian is easily installed in or alongside any existing distribution board with a three-phase supply. For complete protection, it should be connected to the main incoming supply and at each distribution board within the infrastructure, providing essential protection against conditions typically undetected by standard building circuit breakers, RCDs, MCBs, or surge protection devices.

Caractéristiques

  • Simple installation and commissioning
  • Visual display of alerts and status
  • Ethernet connection to cloud based platform
  • Modbus connection for 3rd party building management systems
  • Standard 3-year parts warranty

Applications

  • Power Utilities
  • Data Centres
  • Commercial Buildings
  • Schools
  • Hospitals
  • Farms
  • Rail Network
  • Smart Buildings
  • E-Mobility
  • Energy Storage
  • Renewable Energy Farms
  • Hotels
  • Hospitality Industry
  • Highrise Apartments
  • Care Homes
  • Supermarkets
  • Marinas

Spécifications pour le Trumeter APM-VT-PWR-HV-D345

Measurement Inputs
Maximum Load 10 W
Single Phase 100 to 277 V AC 50 to 60Hz
Split Phase 100 to 277 V AC 50 to 60Hz
3 Phase 100 to 480 V AC 50 to 60Hz
Outputs
Relay Contacts DC-13: 30 V / 5 A MAX
AC-15: 277 V / 5 A MAX
Minimum Recommended Wetting Current 50 mA
Connections
Type Spring Clamp
Wire Type Copper Solid or Stranded
Minimum Cable Temperature Rating 149°F (65°C)
Wire Strip Length 0.26 to 0.28" (6.5 to 7 mm)
Wire Gauge 18 to 12 AWG (0.8 to 3.3 mm2)
Environment
Temperature Operating: -4 to 140°F (-20 to 60°C)
Storage: -4 to 158°F (-20 to 70°C)
Altitude 2000 m
Relative Humidity (non-Condensing) 1 to 85%
Measurement Category II
Overvoltage Category (IEC664) II
Pollution Degree (IEC664) 2
IP Rating (from The Front) IP20

Le Trumeter APM-VT-PWR-HV-D345 comprend

  • Trumeter APM-VT-PWR-HV-D345 Guardian Power and Protective Conductor Monitoring with visual display of alerts and status

Poser une question sur le Trumeter APM-VT-PWR-HV-D345 Guardian Power and Protective Conductor Monitoring with visual display of alerts and status

Trumeter APM-VT-PWR-HV-D345 offre

The Guardian is an advanced power and protective conductor monitoring system, designed to detect and safeguard electrical systems against broken neutral faults and stray voltages on connected services. It continuously monitors the electricity supply and electrical infrastructure, with the capability to isolate or alert any detected faults, including loss of neutral, broken PEN conductors, voltage on protective earth/ground conductors, high and low line voltages and frequencies.

Incorporating patented O-PEN® technology from matt:e, a leading expert in broken neutral and PEN fault protection products, the Guardian provides comprehensive protection to assets and people, including cloud-based real-time monitoring with matt:e cloud, with SMS and email alerts for potential failures.

The Guardian is easily installed in or alongside any existing distribution board with a three-phase supply. For complete protection, it should be connected to the main incoming supply and at each distribution board within the infrastructure, providing essential protection against conditions typically undetected by standard building circuit breakers, RCDs, MCBs, or surge protection devices.

Caractéristiques

  • Simple installation and commissioning
  • Visual display of alerts and status
  • Ethernet connection to cloud based platform
  • Modbus connection for 3rd party building management systems
  • Standard 3-year parts warranty

Applications

  • Power Utilities
  • Data Centres
  • Commercial Buildings
  • Schools
  • Hospitals
  • Farms
  • Rail Network
  • Smart Buildings
  • E-Mobility
  • Energy Storage
  • Renewable Energy Farms
  • Hotels
  • Hospitality Industry
  • Highrise Apartments
  • Care Homes
  • Supermarkets
  • Marinas

Spécifications pour le Trumeter APM-VT-PWR-HV-D345

Measurement Inputs
Maximum Load 10 W
Single Phase 100 to 277 V AC 50 to 60Hz
Split Phase 100 to 277 V AC 50 to 60Hz
3 Phase 100 to 480 V AC 50 to 60Hz
Outputs
Relay Contacts DC-13: 30 V / 5 A MAX
AC-15: 277 V / 5 A MAX
Minimum Recommended Wetting Current 50 mA
Connections
Type Spring Clamp
Wire Type Copper Solid or Stranded
Minimum Cable Temperature Rating 149°F (65°C)
Wire Strip Length 0.26 to 0.28" (6.5 to 7 mm)
Wire Gauge 18 to 12 AWG (0.8 to 3.3 mm2)
Environment
Temperature Operating: -4 to 140°F (-20 to 60°C)
Storage: -4 to 158°F (-20 to 70°C)
Altitude 2000 m
Relative Humidity (non-Condensing) 1 to 85%
Measurement Category II
Overvoltage Category (IEC664) II
Pollution Degree (IEC664) 2
IP Rating (from The Front) IP20

Le Trumeter APM-VT-PWR-HV-D345 comprend

  • Trumeter APM-VT-PWR-HV-D345 Guardian Power and Protective Conductor Monitoring with visual display of alerts and status

Poser une question sur le Trumeter APM-VT-PWR-HV-D345 Guardian Power and Protective Conductor Monitoring with visual display of alerts and status

Plus de produits Trumeter