Tempo T23424OL-APC Ultra-Stable 2 W Loss Length ORL Tester with both 850 and 1330, and 1310 and 1550 nm ports

Modèle: T23424OL-APC | CUP: 810025419318

Tempo T23424OL-APC Ultra-Stable 2 W Loss Length ORL Tester with both 850 and 1330, and 1310 and 1550 nm ports

Modèle: T23424OL-APC | CUP: 810025419318

A Quad Two-Way Optical Loss Test set OLTS fiber tester that's perfect for medium to ultra high fiber count loss, length, and optical return loss testing applications on both multimode and single mode fiber with APC connectors on both ports at 850 and 1330 nm, and 1310 and 1550 nm.

A Quad Two-Way Optical Loss Test set OLTS fiber tester that's perfect for medium to ultra high fiber count loss, length, and optical return loss testing applications on both multimode and single mode fiber with APC connectors on both ports at 850 and 1330 nm, and 1310 and 1550 nm.

Votre prix $13158.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Tempo Communications T23424OL-APC offre

A pair of these compact SM and MM instruments set new standards of productivity, ultra-stable source accuracy and ease of use. A multimode APC connector on this model is required for reliable ORL test performance.

Each fiber needs just one test hook-up and one key press for a complete bidirectional loss, length and ORL test, and the same test method is used for both multimode and single mode fiber, eliminating administration, training and test errors. Testing is accurate and can take only 5 seconds, direct onto flexible standards-compliant Tier 1 certification reports.

The optical fiber length measurement feature is accurate, integrated with the other measurements, and requires only one fiber to be hooked up.

A pair of instruments both display length, bi-directional loss and ORL each end in real time, with no need to specify master/slave instruments. A single OLTS instrument can also be used as a stand-alone ultra-stable light source, power meter, ORL meter or tone generator and detector.

Caractéristiques

  • 25% of the size and weight, 7x the battery life of competitors
  • Bidirectional Autotest loss, length and ORL testing on one fiber
  • Full-feature optical return loss tester
  • Real time Pass and Fail display
  • 8000 fiber memory and USB Flash Drive file dump
  • KITS™ reporting software
  • Autotest optical power meter, >25 λ, 1% accuracy
  • Traceable calibration reports: Power meter and linearity, source λ and stability, ORL
  • 80 hours alkaline battery life
  • 3 Year warranty and calibration cycle
  • EF compliant multimode sources

Spécifications pour le Tempo Communications T23424OL-APC

Source
Output Wavelength Port 1: 1310 and 1550 nm Laser APC
Port 3: 850 and 1300 nm LED APC
Output Power -3 dBm ±1 dB (at 9/125 μm for 1310 and 1550 m)
-23 dBm ±1 dB (at 62.5/125 μm for 850 and 1300 nm)
Adjust Output Power Adjustable over 7 dB in 0.01 dB steps (for 1310 and 1550 nm)
Fixed (for 850 and 1300 nm)
Short Term Stability For 15 minutes, typical ±2°C, after warm up, ORL < -25 dB:
  • 0.03 dB (for 1310 and 1550 nm)
  • 0.01 dB (for 850 and 1300 nm)
Stability Over Temperature 0.2 dB (maximum for 1310 and 1550 nm)
0.35 dB (maximum for 850 and 1300 nm)
Wavelength Initial Tolerance at 25°C 20 nm (for 1310 and 1550 nm)
Wavelength Drift 0.4 nm per °C (typical for 1310 and 1550 nm)
0.4 nm per °C (typical for 850 and 1300 nm)
Mode Controlled 850 and 1300 nm
50/125μm compliant:
  • IEC 61280-4-1 {Ed.1.0}
  • TIA 526-14A
  • TIA TSB-178
Spectrum Width at FWHM 3 nm (typical for 1310 and 1550 nm)
Reconnection Repeatability 0.1 dB (for 1310 and 1550 nm Laser) at 95% confidence
0.05 dB (for 850 and 1300 nm LED) at 95% confidence
2-way Autotest Only
Length Range 6 dB at 62.5 μm (for 850 and 1300 nm)
30 dB (for 1310 and 1550 nm)
Length Accuracy 0.01% ±4 m
2-way Autotest
Length Resolutions 1 m (0.000 to 9.999 Km)
10 m (10.00 to 99.99 Km)
100 m (100.0 to 127.9 Km)
Loss Range 27 dB at 62.5 μm (for 850 and 1300 nm)
47 dB (for 1310 and 1550 nm)
Loss Repeatability and Loss Linearity 0.06 dB (for 850 and 1300 nm)
0.04 dB (for 1310 and 1550 nm)
1-way Autotest
Loss Range 27 dB at 62.5 μm (for 850 and 1300 nm)
47 dB (for 1310 and 1550 nm)
Loss Repeatability and Loss Linearity 0.06 dB (for 850 and 1300 nm)
0.04 dB (for 1310 and 1550 nm)
Meter
Detector Type InGaAs
Response Wavelength 600 and 1700 nm
Calibration Wavelengths 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
Accuracy 1% (0.06 dB)
Mid-Range Linearity Typically 0.04 dB
Power Range 10 to -60 dBm (780 and 980, and 1590 and 1650 nm)
10 to -70 dBm (1270 and 1650 nm)
Total Uncertainty 0.3 dB maximum
Battery Life Laser and LED source: Typically 80 hours in Autotest
Power Meter: Typically 1000 hours
Resolution 0.01 dB
Polarization Sensitivity Typicallly <0.05 dB
ID Tone Detection and Autotest Sensitivity Up to -50 dBm
Tone Detection 150 to 9999 Hz ±1%
Software KITS - free download
ORL Range 0 to >60 dB (1310 and 1550 nm)
0 to 30 dB at 62.5 μm
ORL Port Isolation >60 dB (1310 and 1550 nm)
>25 dB (850 and 1300 nm)
ORL Resolution For 1310 and 1550 nm:
  • 0.01 dB (at 0 to 50 dB)
  • 0.1 dB (at 50 to 65 dB)
For 850 and 1300 nm:
  • 0.01 dB (at 0 to 30 dB)
  • 0.1 dB (at 30 to 45 dB)
ORL Accuracy 0.2 dB
Autotest 1-way: Compatible with other T23400 and T27400 models
2-way: Compatible with identical model only
Power Battery
External power via USB
Battery Type 2 x AA (LR6) Alkaline
2 x AA NiMH AA (rechargeable via USB)
Auto Off Selectable
USB Interfaces USB-micro for power and software
USB-A for memory key
Display 2.9 x 2.2" (74 x 55 mm) high contrast LCD
Case Polycarbonate body
Rubber edges and corners
Moisture resistance
1 m drop tested
Memory For 8000 fibers
Unlimited on USB
Temperature Operating temperature: 5 to 131°F (-15 to 55°C)
Storage temperature: -13 to 158°F (-25 to 70°C)
Relative Humidity 0 to 95%
Warranty 3 years
Calibration Validity ISO/IEC 17025 3 years
Dimensions 7.4 x 4.1 x 1.4" (190 x 105 x 35 mm)
Weight 0.93 lbs (0.42 kg)
Shipping Weight 3.3 lbs (1.5 kg)

Le Tempo Communications T23424OL-APC comprend

  • Tempo T23424OL-APC Ultra-Stable 2 W Loss Length ORL Tester with both 850 - 1330 and 1310 - 1550 nm ports
  • Three-Years Warranty

Poser une question sur le Tempo T23424OL-APC Ultra-Stable 2 W Loss Length ORL Tester with both 850 and 1330, and 1310 and 1550 nm ports

Tempo Communications T23424OL-APC offre

A pair of these compact SM and MM instruments set new standards of productivity, ultra-stable source accuracy and ease of use. A multimode APC connector on this model is required for reliable ORL test performance.

Each fiber needs just one test hook-up and one key press for a complete bidirectional loss, length and ORL test, and the same test method is used for both multimode and single mode fiber, eliminating administration, training and test errors. Testing is accurate and can take only 5 seconds, direct onto flexible standards-compliant Tier 1 certification reports.

The optical fiber length measurement feature is accurate, integrated with the other measurements, and requires only one fiber to be hooked up.

A pair of instruments both display length, bi-directional loss and ORL each end in real time, with no need to specify master/slave instruments. A single OLTS instrument can also be used as a stand-alone ultra-stable light source, power meter, ORL meter or tone generator and detector.

Caractéristiques

  • 25% of the size and weight, 7x the battery life of competitors
  • Bidirectional Autotest loss, length and ORL testing on one fiber
  • Full-feature optical return loss tester
  • Real time Pass and Fail display
  • 8000 fiber memory and USB Flash Drive file dump
  • KITS™ reporting software
  • Autotest optical power meter, >25 λ, 1% accuracy
  • Traceable calibration reports: Power meter and linearity, source λ and stability, ORL
  • 80 hours alkaline battery life
  • 3 Year warranty and calibration cycle
  • EF compliant multimode sources

Spécifications pour le Tempo Communications T23424OL-APC

Source
Output Wavelength Port 1: 1310 and 1550 nm Laser APC
Port 3: 850 and 1300 nm LED APC
Output Power -3 dBm ±1 dB (at 9/125 μm for 1310 and 1550 m)
-23 dBm ±1 dB (at 62.5/125 μm for 850 and 1300 nm)
Adjust Output Power Adjustable over 7 dB in 0.01 dB steps (for 1310 and 1550 nm)
Fixed (for 850 and 1300 nm)
Short Term Stability For 15 minutes, typical ±2°C, after warm up, ORL < -25 dB:
  • 0.03 dB (for 1310 and 1550 nm)
  • 0.01 dB (for 850 and 1300 nm)
Stability Over Temperature 0.2 dB (maximum for 1310 and 1550 nm)
0.35 dB (maximum for 850 and 1300 nm)
Wavelength Initial Tolerance at 25°C 20 nm (for 1310 and 1550 nm)
Wavelength Drift 0.4 nm per °C (typical for 1310 and 1550 nm)
0.4 nm per °C (typical for 850 and 1300 nm)
Mode Controlled 850 and 1300 nm
50/125μm compliant:
  • IEC 61280-4-1 {Ed.1.0}
  • TIA 526-14A
  • TIA TSB-178
Spectrum Width at FWHM 3 nm (typical for 1310 and 1550 nm)
Reconnection Repeatability 0.1 dB (for 1310 and 1550 nm Laser) at 95% confidence
0.05 dB (for 850 and 1300 nm LED) at 95% confidence
2-way Autotest Only
Length Range 6 dB at 62.5 μm (for 850 and 1300 nm)
30 dB (for 1310 and 1550 nm)
Length Accuracy 0.01% ±4 m
2-way Autotest
Length Resolutions 1 m (0.000 to 9.999 Km)
10 m (10.00 to 99.99 Km)
100 m (100.0 to 127.9 Km)
Loss Range 27 dB at 62.5 μm (for 850 and 1300 nm)
47 dB (for 1310 and 1550 nm)
Loss Repeatability and Loss Linearity 0.06 dB (for 850 and 1300 nm)
0.04 dB (for 1310 and 1550 nm)
1-way Autotest
Loss Range 27 dB at 62.5 μm (for 850 and 1300 nm)
47 dB (for 1310 and 1550 nm)
Loss Repeatability and Loss Linearity 0.06 dB (for 850 and 1300 nm)
0.04 dB (for 1310 and 1550 nm)
Meter
Detector Type InGaAs
Response Wavelength 600 and 1700 nm
Calibration Wavelengths 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
Accuracy 1% (0.06 dB)
Mid-Range Linearity Typically 0.04 dB
Power Range 10 to -60 dBm (780 and 980, and 1590 and 1650 nm)
10 to -70 dBm (1270 and 1650 nm)
Total Uncertainty 0.3 dB maximum
Battery Life Laser and LED source: Typically 80 hours in Autotest
Power Meter: Typically 1000 hours
Resolution 0.01 dB
Polarization Sensitivity Typicallly <0.05 dB
ID Tone Detection and Autotest Sensitivity Up to -50 dBm
Tone Detection 150 to 9999 Hz ±1%
Software KITS - free download
ORL Range 0 to >60 dB (1310 and 1550 nm)
0 to 30 dB at 62.5 μm
ORL Port Isolation >60 dB (1310 and 1550 nm)
>25 dB (850 and 1300 nm)
ORL Resolution For 1310 and 1550 nm:
  • 0.01 dB (at 0 to 50 dB)
  • 0.1 dB (at 50 to 65 dB)
For 850 and 1300 nm:
  • 0.01 dB (at 0 to 30 dB)
  • 0.1 dB (at 30 to 45 dB)
ORL Accuracy 0.2 dB
Autotest 1-way: Compatible with other T23400 and T27400 models
2-way: Compatible with identical model only
Power Battery
External power via USB
Battery Type 2 x AA (LR6) Alkaline
2 x AA NiMH AA (rechargeable via USB)
Auto Off Selectable
USB Interfaces USB-micro for power and software
USB-A for memory key
Display 2.9 x 2.2" (74 x 55 mm) high contrast LCD
Case Polycarbonate body
Rubber edges and corners
Moisture resistance
1 m drop tested
Memory For 8000 fibers
Unlimited on USB
Temperature Operating temperature: 5 to 131°F (-15 to 55°C)
Storage temperature: -13 to 158°F (-25 to 70°C)
Relative Humidity 0 to 95%
Warranty 3 years
Calibration Validity ISO/IEC 17025 3 years
Dimensions 7.4 x 4.1 x 1.4" (190 x 105 x 35 mm)
Weight 0.93 lbs (0.42 kg)
Shipping Weight 3.3 lbs (1.5 kg)

Le Tempo Communications T23424OL-APC comprend

  • Tempo T23424OL-APC Ultra-Stable 2 W Loss Length ORL Tester with both 850 - 1330 and 1310 - 1550 nm ports
  • Three-Years Warranty

Poser une question sur le Tempo T23424OL-APC Ultra-Stable 2 W Loss Length ORL Tester with both 850 and 1330, and 1310 and 1550 nm ports

Plus de produits Tempo Communications