RKI SDM-2009 Stand-Alone Calibration Station with demand flow regulator for the GX-2009

Modèle: 81-SDM2009-02

RKI SDM-2009 Stand-Alone Calibration Station with demand flow regulator for the GX-2009

Modèle: 81-SDM2009-02

Compatible with the GX-2009 portable gas monitor, this calibration station is a versatile maintenance tool that automates the gas monitor service and is ideal for charging, calibration, and bump testing. In addition, it automatically stores records for future upload to a PC via a USB flash drive and includes a demand flow regulator.

Compatible with the GX-2009 portable gas monitor, this calibration station is a versatile maintenance tool that automates the gas monitor service and is ideal for charging, calibration, and bump testing. In addition, it automatically stores records for future upload to a PC via a USB flash drive and includes a demand flow regulator.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :

RKI SDM-3R Station d'étalonnage avec 1 solénoïde, régulateur de débit à la demande, adaptateur CA, clé USB, câble USB et tubes-

RKI SDM-3R Station d'étalonnage avec 1 solénoïde, régulateur de débit à la demande, adaptateur CA, clé USB, câble USB et tubes

Modèle: 81-SDM3R102

La SDM-3R est un outil d'entretien polyvalent qui automatise la maintenance du moniteur de gaz portable GX-3R (Pro).


RKI 81-SDM2009-02 offre

Caractéristiques

  • Stand-alone station (no PC required)
  • Charging
  • Calibration
  • Bump test
  • Save bump test and calibration records
  • Bump test and calibration records copy to USB jump drive
  • Includes PC software for viewing/archiving bump test and calibration records

Applications

  • Gas detection

Spécifications pour le RKI 81-SDM2009-02

Applicable Instruments GX-2009
Input Power 12 V DC
Note: AC adapter with 100 to 240 V AC, 50/60 Hz, 0.6 A input and 12 V DC, 1.2 A output provided as standard
Environmental Conditions For indoor use only
14 to 104°F (-10 to 40°C), below 80% relative humidity, non-condensing
Maximum Number of Records Saved 200 (stand-alone)
Unlimited with software
Ports 1 Calibration gas, 1 fresh air, and 1 exhaust

Le RKI 81-SDM2009-02 comprend

  • Calibration Station
  • Demand Flow Regulator
  • Tubing
  • USB Cable
  • Flash Drive
  • AC Adapter
  • Installation CD
  • One-Year Warranty

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le RKI SDM-2009 Stand-Alone Calibration Station with demand flow regulator for the GX-2009.

RKI 81-0089RK-03 Cylindre, 103 L 81-0089RK-03
Convient pour CO 50 ppm, hexane 15% LIE, O2 12% dans N2.




RKI 81-0158RK-04 Cylindre en aluminium, 34 L 81-0158RK-04
Comprend 25 ppm H2S, 50 ppm CO, 50% LIE isobutane, 12% O2 dans N2.




RKI 81-0158RK-02 Cylindre en aluminium, 58 L 81-0158RK-02
Comprend 25 ppm H2S, 50 ppm CO, 50% LIE isobutane et 12% O50.8 mm (2") N2.




RKI 81-0155RK-02 Aluminum Cylinder, 58 L 81-0155RK-02
Features 25 ppm H2S, 50 ppm CO, 15% LEL HEX, and 12% 02 in N2.




RKI 81-0154RK-04 Aluminum Cylinder, 34 L 81-0154RK-04
Comes with 25 ppm H2S, 50 ppm CO, 50% LEL CH4, and 12% 02 in N2.




RKI 81-0154RK-02 Cylindre en aluminium, 58 L 81-0154RK-02
Comprend 25 ppm H2S, 50 ppm CO, 50% LIE CH4, et 12% 50.8 mm (02") N2.




RKI 81-0151RK-02 Cylindre, 58 AL 81-0151RK-02
Convient pour H2S 25 ppm dans N2.




RKI 81-0090RK-03 Cylindre en acier, 103 L 81-0090RK-03
Livré avec 50 ppm CO/50% LIE et CH4/12% 50.8 mm (02") N2.




RKI 81-0090RK-01 Cylindre en acier, 34 L 81-0090RK-01
Comprend 50 ppm CO/50% LIE et CH4/12% 50.8 mm (02") N2.




RKI 82-6050RK Concentrateur USB, 4 ports 2.0 82-6050RK
Compatible avec la station d'étalonnage autonome, ce concentrateur USB dispose de quatre ports 2.0.




RKI 82-6051RK USB Hub, 7 port 2.0 82-6051RK
Compatible with the stand alone calibration station, this USB Hub features seven ports 2.0.




RKI 81-1055RK Demand-Flow Type Regulator 81-1055RK
Compatible with the 17-liter and 34-liter steel calibration cylinders with external threads.




RKI 81-1054RK Regulator, demand-flow type 81-1054RK
Features a demand-flow type for 58 and 103 L calibration cylinders.




Poser une question sur le RKI SDM-2009 Stand-Alone Calibration Station with demand flow regulator for the GX-2009

RKI 81-SDM2009-02 offre

Caractéristiques

  • Stand-alone station (no PC required)
  • Charging
  • Calibration
  • Bump test
  • Save bump test and calibration records
  • Bump test and calibration records copy to USB jump drive
  • Includes PC software for viewing/archiving bump test and calibration records

Applications

  • Gas detection

Spécifications pour le RKI 81-SDM2009-02

Applicable Instruments GX-2009
Input Power 12 V DC
Note: AC adapter with 100 to 240 V AC, 50/60 Hz, 0.6 A input and 12 V DC, 1.2 A output provided as standard
Environmental Conditions For indoor use only
14 to 104°F (-10 to 40°C), below 80% relative humidity, non-condensing
Maximum Number of Records Saved 200 (stand-alone)
Unlimited with software
Ports 1 Calibration gas, 1 fresh air, and 1 exhaust

Le RKI 81-SDM2009-02 comprend

  • Calibration Station
  • Demand Flow Regulator
  • Tubing
  • USB Cable
  • Flash Drive
  • AC Adapter
  • Installation CD
  • One-Year Warranty

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le RKI SDM-2009 Stand-Alone Calibration Station with demand flow regulator for the GX-2009.

RKI 81-0089RK-03 Cylindre, 103 L 81-0089RK-03
Convient pour CO 50 ppm, hexane 15% LIE, O2 12% dans N2.




RKI 81-0158RK-04 Cylindre en aluminium, 34 L 81-0158RK-04
Comprend 25 ppm H2S, 50 ppm CO, 50% LIE isobutane, 12% O2 dans N2.




RKI 81-0158RK-02 Cylindre en aluminium, 58 L 81-0158RK-02
Comprend 25 ppm H2S, 50 ppm CO, 50% LIE isobutane et 12% O50.8 mm (2") N2.




RKI 81-0155RK-02 Aluminum Cylinder, 58 L 81-0155RK-02
Features 25 ppm H2S, 50 ppm CO, 15% LEL HEX, and 12% 02 in N2.




RKI 81-0154RK-04 Aluminum Cylinder, 34 L 81-0154RK-04
Comes with 25 ppm H2S, 50 ppm CO, 50% LEL CH4, and 12% 02 in N2.




RKI 81-0154RK-02 Cylindre en aluminium, 58 L 81-0154RK-02
Comprend 25 ppm H2S, 50 ppm CO, 50% LIE CH4, et 12% 50.8 mm (02") N2.




RKI 81-0151RK-02 Cylindre, 58 AL 81-0151RK-02
Convient pour H2S 25 ppm dans N2.




RKI 81-0090RK-03 Cylindre en acier, 103 L 81-0090RK-03
Livré avec 50 ppm CO/50% LIE et CH4/12% 50.8 mm (02") N2.




RKI 81-0090RK-01 Cylindre en acier, 34 L 81-0090RK-01
Comprend 50 ppm CO/50% LIE et CH4/12% 50.8 mm (02") N2.




RKI 82-6050RK Concentrateur USB, 4 ports 2.0 82-6050RK
Compatible avec la station d'étalonnage autonome, ce concentrateur USB dispose de quatre ports 2.0.




RKI 82-6051RK USB Hub, 7 port 2.0 82-6051RK
Compatible with the stand alone calibration station, this USB Hub features seven ports 2.0.




RKI 81-1055RK Demand-Flow Type Regulator 81-1055RK
Compatible with the 17-liter and 34-liter steel calibration cylinders with external threads.




RKI 81-1054RK Regulator, demand-flow type 81-1054RK
Features a demand-flow type for 58 and 103 L calibration cylinders.




Poser une question sur le RKI SDM-2009 Stand-Alone Calibration Station with demand flow regulator for the GX-2009

Plus de produits RKI