Megger DET4TCR2 Kit (1000-405)

Modèle: DET4TCR2+Kit

Megger DET4TCR2 Kit (1000-405)-


Télécharger: manual

Plus de produits Megger

Demander à un expert

Megger DET4TCR2 Kit (1000-405)

Modèle: DET4TCR2+Kit

4-Terminal Ground Resistance Tester with Professional Testing Kit, ICLAMP/VCLAMP, ART Capability.

4-Terminal Ground Resistance Tester with Professional Testing Kit, ICLAMP/VCLAMP, ART Capability.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.

Il n’y a pas de remplacement direct, mais nous vous recommandons:

Megger DET4T2 Series 4-Terminal Digital Ground Testers-

Megger DET4T2 Series 4-Terminal Digital Ground Testers

Modèle: DET4TC2 | No. de commande: DET4TC2 Series

Unstoppable with a wide range of capabilities, this ground testing instrument family is perfect for greater testing flexibility. From stakeless capabilities to Attached Rod Technique (ART), everything you need for proper ground testing is at your disposal with practical accessories to improve performance.


Vous ne trouvez pas ce que vous cherchez? Nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin.


Megger DET4TCR2+Kit offre

Megger's popular 4-terminal ground testing instrument family includes four basic models with different kit variants for each that include select accessories for greater testing flexibility.

The top-end models (DET4TC2 and DET4TCR2) include a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document). They also provide stakeless testing capability. This method allows the operator to use the instrument like a clamp-on ground tester in applications where that method is viable, while also being able to operate as a fall of potential tester if required.

The basic kit includes the test leads, stakes, batteries and calibration certificate, delivered in a tough polypropylene carry case - everything you need to start testing in one package.

All models are rated to IP54, making them truly outdoor instruments. They are designed to meet stringent safety standards and are rated CAT IV 100 V. The ground testers have been designed to be easy to use - a large selector switch makes selection of 2, 3 or 4 pole tests easy with gloved hands - and the design makes the fitting of shorting links to perform 2-pole tests a thing of the past. A large, clear, easy to read LCD and thumb sized test button also make the instruments particularly well suited to the outdoor conditions of ground testing. In addition to this ease of use feature, the instruments automatically check the connection and conditions of the P spike, C spike, and also the level of ground noise, indicating the status on the display. They also include a voltmeter to enable measurement of ground voltage.

The DET4TD2 and DET4TR2 can measure resistance from 0.01 ohms to 20 kΩ, while the DET4TC2 and DET4TCR2 can measure resistance from 0.01 ohms to 200 kΩ, a key capability for soil resistivity testing. Also, to allow accurate testing in noisy environments, the instruments are capable of rejecting noise up to 40 V peak to peak.

The DET4TD2 and DET4TC2 are powered by eight AA batteries which are widely available and also give excellent testing time - the status of these batteries is given by a bar graph on the LCD display, allowing the operator to decide when to change the batteries before they expire. The DET4TR2 and DET4TCR2 are powered from rechargeable AA cells. The battery charger is built in and the instrument is supplied with an AC/DC adapter. For all instruments, the battery status is displayed using a bar-graph.

The DET4TC2 and DET4TCR2 include additional capabilities. By using the optional ICLAMP the user can augment the traditional fall-of-potential measurement method with ART (Attached Rod Technique), which allows electrode testing without disconnection and also leakage current measurements down to 0.5 mA. A second optional clamp, the VCLAMP, enables true stakeless (clamp-on) measurements to be made in situations where driving stakes is not practical.

The DET4TC2 and DET4TCR2 also feature a backlit display, which extends the operational environment of the instrument to cable cellars and other dark locations. Finally, all units have selectable 25 V or 50 V output for compliance with IEC 61557-5. The 25 V output is required for testing in agricultural environments.


Applications

Proper grounding provides many varied benefits to both people and facilities. It lessens the chance of injury due to faulty installation, reduces the likelihood of damage from lightning strikes and induced voltages, improves the performance of computer, communication and other sensitive equipment and protects against static electricity from friction. Over time, ground systems can degrade or become ineffective. Corrosion and weather influences exert mechanical strain on ground rods and cause metallic corrosion. Catastrophic events like lightning strikes or large fault currents can cause instant degradation. In addition, soil resistivity can change over time due to environmental conditions and facility expansion can create different ground system needs.

The risks from ground system deterioration include potentially deadly electrical shock situations, plant-wide equipment damage, disruption in the performance of sensitive equipment and heat build-up on a single piece of electrical equipment.

The maintenance of an adequate low resistance ground connection is essential to both the protection and performance of any electrical system. Ground testing should be performed both upon installation, to meet design specification, and periodically thereafter in order to maintain service. All Megger models can also perform bonding tests (using an ac signal), to determine that adequate connection has been made from equipment to the grounding system, and can perform soil resistivity tests. This additional function can be used in prospecting, locating, and designing new grounding electrodes and systems. Furthermore, the addition of built-in current clamp capability enables fall of potential testing of attached grounds (ART) without lifting the utility connection and the addition of voltage clamp technology enables stakeless testing from the same instrument.

Grounding electrodes from simple to complex systems can be tested, including:

  • Primary and secondary electrical grounding systems
  • Utility pole grounds
  • Lightning protection systems
  • Residential grounds
  • Machinery safety grounds
  • Computer and communication system grounds
  • EMI/RFI system grounds
  • Antenna and pedestal grounds
  • CATV system grounds


What's Included

  • Three sets of leads
  • Two test spikes
  • Instruction manual CD
  • Rugged carrying case
  • Certificate of Calibration
  • 2 Year Warranty

Spécifications pour le Megger DET4TCR2+Kit

Resistance Range 0.01 Ω to 20 kΩ
Resistance Accuracy 2% ±3 digits
Earth Voltage Range 0 to 100 V AC
Earth Voltage Accuracy 2% ±2 V
C Spike Check Automatic
P Spike Check Automatic
Noise Check Automatic
Noise Rejection 40 V pk to pk
2-Wire Test Yes
3-Wire Test Yes
4-Wire Test Yes
Display LCD
Battery Type 8 x 1.5 V AA cells
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Safety EN61010-1 CAT IV 100 V
Ingress Protection IP54
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.20 lbs (1 kg)

Le Megger DET4TCR2+Kit comprend

  • Megger DET4TCR2 Kit (1000-405)

Selection Guide DET4TD2 DET4TR2 DET4TC2 DET4TCR2
Tests 2-Pole Measurement
3-Pole Measurement
4-Pole Measurement
Soil Resistivity
ART (Attached Rod Technique) Capability
Stakeless (Clamp-on) Measurement Capability
Resistance Range 0.01 to 20,000 Ω 0.01 to 200,000 Ω
Ground Voltage Range 0 to 100 V
Ground Current Range (with ICLAMP) Capability 0.5 mA to 19.9 A
Output Selectable Voltage (25/50 V)
Test Frequency 128 Hz 94, 105, 111, 128 Hz
Power Supply Alkaline Batteries
Rechargeable Batteries
Noise Rejection 40 V Peak-to-Peak
Safety Rating CAT IV 100 V
Ingress Protection Rated to IP54
Included Accessories Hard Carry Case
Test Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes
Certificate of Calibration
Warranty 2 Year

Webinaire: Comment les tests de mise à la terre assurent notre sécurité avec Megger


Les dispositifs principaux de mise &agrave; la terre sont essentiels en raison de la protection et de la s&eacute;curit&eacute; qu&rsquo;ils offrent au public et &agrave; l'&eacute;quipement &eacute;lectrique que nous utilisons tous les jours. Ces dispositifs doivent &ecirc;tre surveill&eacute;s et entretenus pour garantir leur fiabilit&eacute; dans des conditions normales, lors de pannes inattendues et pour pr&eacute;venir les pannes en cascade.<br/><br/>Nous avons fait &eacute;quipe avec Megger pour ce court webinaire sur les tests de r&eacute;sistance de mise &agrave; la terre, o&ugrave; nous couvrons:<br/>&bull; Comment les tests de r&eacute;sistance de mise &agrave; la terre nous gardent en s&eacute;curit&eacute;<br/>&bull; Th&eacute;orie des tests de r&eacute;sistance de mise &agrave; la terre<br/>&bull; Tension d&rsquo;&eacute;tape et tension de contact<br/>&bull; R&eacute;sistance du sol &ndash; test pour les nouvelles installations<br/>&bull; R&eacute;sistance de mise &agrave; la terre et &eacute;lectrode &ndash; test d&rsquo;entretien<br/>&bull; Technique de tige fix&eacute;e &ndash; test sans d&eacute;branchement<br/>&bull; Essai d&rsquo;&eacute;lectrode sans piquet &ndash; avantages des pinces<br/>&bull; Test dans des environnements &eacute;lectriques bruyants

Poser une question sur le Megger DET4TCR2 Kit (1000-405)

Megger DET4TCR2+Kit offre

Megger's popular 4-terminal ground testing instrument family includes four basic models with different kit variants for each that include select accessories for greater testing flexibility.

The top-end models (DET4TC2 and DET4TCR2) include a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document). They also provide stakeless testing capability. This method allows the operator to use the instrument like a clamp-on ground tester in applications where that method is viable, while also being able to operate as a fall of potential tester if required.

The basic kit includes the test leads, stakes, batteries and calibration certificate, delivered in a tough polypropylene carry case - everything you need to start testing in one package.

All models are rated to IP54, making them truly outdoor instruments. They are designed to meet stringent safety standards and are rated CAT IV 100 V. The ground testers have been designed to be easy to use - a large selector switch makes selection of 2, 3 or 4 pole tests easy with gloved hands - and the design makes the fitting of shorting links to perform 2-pole tests a thing of the past. A large, clear, easy to read LCD and thumb sized test button also make the instruments particularly well suited to the outdoor conditions of ground testing. In addition to this ease of use feature, the instruments automatically check the connection and conditions of the P spike, C spike, and also the level of ground noise, indicating the status on the display. They also include a voltmeter to enable measurement of ground voltage.

The DET4TD2 and DET4TR2 can measure resistance from 0.01 ohms to 20 kΩ, while the DET4TC2 and DET4TCR2 can measure resistance from 0.01 ohms to 200 kΩ, a key capability for soil resistivity testing. Also, to allow accurate testing in noisy environments, the instruments are capable of rejecting noise up to 40 V peak to peak.

The DET4TD2 and DET4TC2 are powered by eight AA batteries which are widely available and also give excellent testing time - the status of these batteries is given by a bar graph on the LCD display, allowing the operator to decide when to change the batteries before they expire. The DET4TR2 and DET4TCR2 are powered from rechargeable AA cells. The battery charger is built in and the instrument is supplied with an AC/DC adapter. For all instruments, the battery status is displayed using a bar-graph.

The DET4TC2 and DET4TCR2 include additional capabilities. By using the optional ICLAMP the user can augment the traditional fall-of-potential measurement method with ART (Attached Rod Technique), which allows electrode testing without disconnection and also leakage current measurements down to 0.5 mA. A second optional clamp, the VCLAMP, enables true stakeless (clamp-on) measurements to be made in situations where driving stakes is not practical.

The DET4TC2 and DET4TCR2 also feature a backlit display, which extends the operational environment of the instrument to cable cellars and other dark locations. Finally, all units have selectable 25 V or 50 V output for compliance with IEC 61557-5. The 25 V output is required for testing in agricultural environments.


Applications

Proper grounding provides many varied benefits to both people and facilities. It lessens the chance of injury due to faulty installation, reduces the likelihood of damage from lightning strikes and induced voltages, improves the performance of computer, communication and other sensitive equipment and protects against static electricity from friction. Over time, ground systems can degrade or become ineffective. Corrosion and weather influences exert mechanical strain on ground rods and cause metallic corrosion. Catastrophic events like lightning strikes or large fault currents can cause instant degradation. In addition, soil resistivity can change over time due to environmental conditions and facility expansion can create different ground system needs.

The risks from ground system deterioration include potentially deadly electrical shock situations, plant-wide equipment damage, disruption in the performance of sensitive equipment and heat build-up on a single piece of electrical equipment.

The maintenance of an adequate low resistance ground connection is essential to both the protection and performance of any electrical system. Ground testing should be performed both upon installation, to meet design specification, and periodically thereafter in order to maintain service. All Megger models can also perform bonding tests (using an ac signal), to determine that adequate connection has been made from equipment to the grounding system, and can perform soil resistivity tests. This additional function can be used in prospecting, locating, and designing new grounding electrodes and systems. Furthermore, the addition of built-in current clamp capability enables fall of potential testing of attached grounds (ART) without lifting the utility connection and the addition of voltage clamp technology enables stakeless testing from the same instrument.

Grounding electrodes from simple to complex systems can be tested, including:

  • Primary and secondary electrical grounding systems
  • Utility pole grounds
  • Lightning protection systems
  • Residential grounds
  • Machinery safety grounds
  • Computer and communication system grounds
  • EMI/RFI system grounds
  • Antenna and pedestal grounds
  • CATV system grounds


What's Included

  • Three sets of leads
  • Two test spikes
  • Instruction manual CD
  • Rugged carrying case
  • Certificate of Calibration
  • 2 Year Warranty

Spécifications pour le Megger DET4TCR2+Kit

Resistance Range 0.01 Ω to 20 kΩ
Resistance Accuracy 2% ±3 digits
Earth Voltage Range 0 to 100 V AC
Earth Voltage Accuracy 2% ±2 V
C Spike Check Automatic
P Spike Check Automatic
Noise Check Automatic
Noise Rejection 40 V pk to pk
2-Wire Test Yes
3-Wire Test Yes
4-Wire Test Yes
Display LCD
Battery Type 8 x 1.5 V AA cells
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Safety EN61010-1 CAT IV 100 V
Ingress Protection IP54
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.20 lbs (1 kg)

Le Megger DET4TCR2+Kit comprend

  • Megger DET4TCR2 Kit (1000-405)

Selection Guide DET4TD2 DET4TR2 DET4TC2 DET4TCR2
Tests 2-Pole Measurement
3-Pole Measurement
4-Pole Measurement
Soil Resistivity
ART (Attached Rod Technique) Capability
Stakeless (Clamp-on) Measurement Capability
Resistance Range 0.01 to 20,000 Ω 0.01 to 200,000 Ω
Ground Voltage Range 0 to 100 V
Ground Current Range (with ICLAMP) Capability 0.5 mA to 19.9 A
Output Selectable Voltage (25/50 V)
Test Frequency 128 Hz 94, 105, 111, 128 Hz
Power Supply Alkaline Batteries
Rechargeable Batteries
Noise Rejection 40 V Peak-to-Peak
Safety Rating CAT IV 100 V
Ingress Protection Rated to IP54
Included Accessories Hard Carry Case
Test Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes
Certificate of Calibration
Warranty 2 Year

Webinaire: Comment les tests de mise &agrave; la terre assurent notre s&eacute;curit&eacute; avec Megger


Les dispositifs principaux de mise &agrave; la terre sont essentiels en raison de la protection et de la s&eacute;curit&eacute; qu&rsquo;ils offrent au public et &agrave; l'&eacute;quipement &eacute;lectrique que nous utilisons tous les jours. Ces dispositifs doivent &ecirc;tre surveill&eacute;s et entretenus pour garantir leur fiabilit&eacute; dans des conditions normales, lors de pannes inattendues et pour pr&eacute;venir les pannes en cascade.<br/><br/>Nous avons fait &eacute;quipe avec Megger pour ce court webinaire sur les tests de r&eacute;sistance de mise &agrave; la terre, o&ugrave; nous couvrons:<br/>&bull; Comment les tests de r&eacute;sistance de mise &agrave; la terre nous gardent en s&eacute;curit&eacute;<br/>&bull; Th&eacute;orie des tests de r&eacute;sistance de mise &agrave; la terre<br/>&bull; Tension d&rsquo;&eacute;tape et tension de contact<br/>&bull; R&eacute;sistance du sol &ndash; test pour les nouvelles installations<br/>&bull; R&eacute;sistance de mise &agrave; la terre et &eacute;lectrode &ndash; test d&rsquo;entretien<br/>&bull; Technique de tige fix&eacute;e &ndash; test sans d&eacute;branchement<br/>&bull; Essai d&rsquo;&eacute;lectrode sans piquet &ndash; avantages des pinces<br/>&bull; Test dans des environnements &eacute;lectriques bruyants

Poser une question sur le Megger DET4TCR2 Kit (1000-405)

Plus de produits Megger

Comment protéger et entretenir efficacement les éoliennes