MadgeTech PR140 Pressure Data Logger with NPT Port

Modèle: PR140

MadgeTech PR140 Pressure Data Logger with NPT Port

Modèle: PR140

Rugged pressure data logger measures from 0 to 5 bar (0 to 72.5 psia), features a 1/8" NPT pressure port, can withstand temperatures up to 140°C, and is completely submersible (IP68).

Rugged pressure data logger measures from 0 to 5 bar (0 to 72.5 psia), features a 1/8" NPT pressure port, can withstand temperatures up to 140°C, and is completely submersible (IP68).

Prix spécial $1327.73 CAD
Prix régulier $1405.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre PR140 Pressure Data Logger with NPT Port

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre PR140 Pressure Data Logger with NPT Port

High Temperature Pressure Data Logger

The PR140 is a pressure data logger designed for use in autoclave validation and mapping. This rugged data logger can withstand temperatures up to 140 °C and is completely submersible (IP68). The PR140 is built with a precision stainless steel pressure gauge. The data logger has an accuracy of ±0.03 Bar (±0.435 PSI), which can be achieved over a wide temperature range, from 20 °C to +140 °C (68 °F to 284 °F). The PR140 can be programmed to take readings as often as once per second (1 Hz), and has non-volatile memory that can store up to 32,700 measurements. The PR140 data logger is easy to use. Simply place it in the IFC400 docking station, connect to a computer, and the device can be started, stopped or downloaded using the MadgeTech software. Graphical, tabular and summary data is provided for analysis and can be viewed in PSIA, mmHg, bar, Torr and kPa. The data can also be automatically exported to Excel® for further calculations.


Features:

  • Operates up to 140°C
  • Submersible (IP68)
  • N.I.S.T. Traceable
  • User Replaceable Battery
  • Rugged
  • Programmable Start Time
  • Engraved Label
  • CE Compliant
  • Software Battery Life Indicator
  • 1/8" NPT Pressure Port
  • Wrench Flats

Applications:

  • Autoclave Validation and Mapping
  • Canning and Cooking Pouches
  • Pressurized Process Reactors
  • Beverage Production, Including Wine and Soda

Specifications:

Pressure Sensor Semiconductor Strain Gauge
Pressure Range 0 to 5 Bar (0 to 72.5 PSIA)
Pressure Resolution 0.1 mBar (0.0015 PSIA)
Pressure Calibrated Accuracy ±0.03 Bar (±0.435 PSI)
20 °C to +140 °C (68 °F to 284 °F)
Memory 32,700 readings; software configurable memory wrap
Reading Rate 1 second to once every 24 hours, selectable in software
Baud Rate 125,000
Battery Life 2 years typical (1 minute reading rate at 25 °C / 77 °F)
Material Stainless Steel
Dimensions 2.29 in x 1.0 in dia. (58.2 mm x 25.4 mm dia.)
IP Rating IP68
Submersible Yes
Operating Environment -20 °C to +140 °C (-4 °F to +284 °F), 0 %RH to 100 %RH
Note: The PR140 may be used above 60 °C for up to 8 hours, per 24 hour period.
Approvals CE
Cliquer ici pour toutes les spécifications du MadgeTech PR140

Le MadgeTech PR140 comprend

  • MadgeTech PR140 Pressure Data Logger with NPT Port

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le MadgeTech PR140 Pressure Data Logger with NPT Port.

MadgeTech SVP-Secure Secure Validation Software SVP-Secure System
IQ/OQ/PQ Secure Software Validation Workbook and Software Package.




MadgeTech IFC400 Ensemble de câbles d'interface IFC400
Ensemble de câbles d'interface pour enregistreurs de données HiTemp140 et PR140. Comprend un CD du logiciel MadgeTech, un manuel du logiciel, un guide de démarrage rapide, un câble USB et une station d'accueil USB.




MadgeTech IFC406 Multiplexer Data Logger Interface IFC406
Multiplexer data logger interface allows for six data loggers to be connected and communicate through one USB port.




Poser une question sur le MadgeTech PR140 Pressure Data Logger with NPT Port

High Temperature Pressure Data Logger

The PR140 is a pressure data logger designed for use in autoclave validation and mapping. This rugged data logger can withstand temperatures up to 140 °C and is completely submersible (IP68). The PR140 is built with a precision stainless steel pressure gauge. The data logger has an accuracy of ±0.03 Bar (±0.435 PSI), which can be achieved over a wide temperature range, from 20 °C to +140 °C (68 °F to 284 °F). The PR140 can be programmed to take readings as often as once per second (1 Hz), and has non-volatile memory that can store up to 32,700 measurements. The PR140 data logger is easy to use. Simply place it in the IFC400 docking station, connect to a computer, and the device can be started, stopped or downloaded using the MadgeTech software. Graphical, tabular and summary data is provided for analysis and can be viewed in PSIA, mmHg, bar, Torr and kPa. The data can also be automatically exported to Excel® for further calculations.


Features:

  • Operates up to 140°C
  • Submersible (IP68)
  • N.I.S.T. Traceable
  • User Replaceable Battery
  • Rugged
  • Programmable Start Time
  • Engraved Label
  • CE Compliant
  • Software Battery Life Indicator
  • 1/8" NPT Pressure Port
  • Wrench Flats

Applications:

  • Autoclave Validation and Mapping
  • Canning and Cooking Pouches
  • Pressurized Process Reactors
  • Beverage Production, Including Wine and Soda

Specifications:

Pressure Sensor Semiconductor Strain Gauge
Pressure Range 0 to 5 Bar (0 to 72.5 PSIA)
Pressure Resolution 0.1 mBar (0.0015 PSIA)
Pressure Calibrated Accuracy ±0.03 Bar (±0.435 PSI)
20 °C to +140 °C (68 °F to 284 °F)
Memory 32,700 readings; software configurable memory wrap
Reading Rate 1 second to once every 24 hours, selectable in software
Baud Rate 125,000
Battery Life 2 years typical (1 minute reading rate at 25 °C / 77 °F)
Material Stainless Steel
Dimensions 2.29 in x 1.0 in dia. (58.2 mm x 25.4 mm dia.)
IP Rating IP68
Submersible Yes
Operating Environment -20 °C to +140 °C (-4 °F to +284 °F), 0 %RH to 100 %RH
Note: The PR140 may be used above 60 °C for up to 8 hours, per 24 hour period.
Approvals CE
Cliquer ici pour toutes les spécifications du MadgeTech PR140

Le MadgeTech PR140 comprend

  • MadgeTech PR140 Pressure Data Logger with NPT Port

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le MadgeTech PR140 Pressure Data Logger with NPT Port.

MadgeTech SVP-Secure Secure Validation Software SVP-Secure System
IQ/OQ/PQ Secure Software Validation Workbook and Software Package.




MadgeTech IFC400 Ensemble de câbles d'interface IFC400
Ensemble de câbles d'interface pour enregistreurs de données HiTemp140 et PR140. Comprend un CD du logiciel MadgeTech, un manuel du logiciel, un guide de démarrage rapide, un câble USB et une station d'accueil USB.




MadgeTech IFC406 Multiplexer Data Logger Interface IFC406
Multiplexer data logger interface allows for six data loggers to be connected and communicate through one USB port.




Poser une question sur le MadgeTech PR140 Pressure Data Logger with NPT Port

Plus de produits MadgeTech