Combines intuitive docking modules and device management software to provide automated instrument management for the Max XT II series multi-gas detectors - helping drive productivity, reliability, and efficiency. Set the module to do a bump test, reconfigure the detector’s high and low alarm setpoints, and more.

Combines intuitive docking modules and device management software to provide automated instrument management for the Max XT II series multi-gas detectors - helping drive productivity, reliability, and efficiency. Set the module to do a bump test, reconfigure the detector’s high and low alarm setpoints, and more.

Prix spécial $2619.92 CAD
Prix régulier $3279.00 CAD
Disponibilité 2 à 3 semaines
Quantité
The following item is required to funtion with your gas detector

The following item is required to funtion with your gas detector


BW DX-MAXXT offre

Combines smart docking modules and device management software to provide automated instrument management for compatible detectors, helping you drive productivity, reliability, and efficiency. Place the detector in the docking module, and automatically test the gas detector and sensors while transferring data to the docking station. The IntelliDoX delivers quicker bump tests for better productivity. You can gang up to five IntelliDoX for even greater productivity, and each module can function independently, managing fleets of detectors, all simultaneously. The station is efficient when networked via Ethernet or stand-alone, transfer data with a USB drive.

Features

  • FastBump test that eliminates bottlenecks, while avoiding costly purge cycles that waste gase
  • Gangable up to five modules, each with its own LCD screen and keypad for independent operation
  • Easy to set up with no tools required
  • Easy to connect via Ethernet to a network
  • USB port to easily configure dock module settings or retrieve data without network access
  • Automated bump test and span calibration operation
  • Device management with Safety Suite Device Configurator
  • Modular nests for device changes
  • Bump testing, calibration, configuration, and record-keeping support for compatible detectors. User updatable settings:
    • Configure alarm settings
    • Display gas reading during alarm
    • Enable non-compliance indicator
    • Hibernate detector
    • Schedule bump test and calibration reminders
    • Transfer event logs
    • Time display preferences
    • Update firmware

Fast instrument management and enhanced productivity

IntelliDoX is easy to install, taking under 2 minutes from setup of a five‑module dock to the bump of your first instrument. Each module has its own operating system, LCD screen and internal pump allowing you to perform more than one operation at the same time. Whether you want to bump three detectors or calibrate others - you can get more done in less time.

Flexible configuration to meet changing needs

Configure the low and high alarm set points - plus other detector parameters - throughout the lifespan of the detector. So you can rely on your detector to always work the way you want it to.

Efficient networking and data transfer for easy record‑keeping

Use either USB or Ethernet to transfer bump tests, peak exposures and other gas‑detection data.

  • A new level of customization for device management
  • Configure alarm set points, track compliance of workers and more
  • Flexible docks and software - expandable to five modules
  • Quick and easy setup - great for turnarounds

Spécifications pour le BW DX-MAXXT

Automatic Tests Automatic bump test to verify sensor responds to target gas
Pump Flow rate: 350 ml/min (independent pump in each module)
Instrument Management System Honeywell SafetySuite
Fleet Manager II, version 4.4 or higher
External Interface 1 USB port, 1 ethernet port
Data Storage 2 GB internal
LCD Display Color Coding Yellow "TEST", Green "PASS", Red "FAIL"
Real-Time Clock Provides time and date stamp
Ratings EMC Directive 2014/30/EU
Low Voltage Directive 2014/35/EU
FCC Part 15
ICES-003 Canadian EMI
IP20
Power Supply 12 V/8.33 A ITE
Dimensions 5.4 x 14.2 x 4.3" (13.8 x 36.2 x 10.9 cm), per docking module
Weight 4.2 lbs (1.91 kg)
Cliquer ici pour toutes les spécifications du BW DX-MAXXT

Le BW DX-MAXXT comprend

  • Docking Station
  • Integrated Retractable Stand/Wall Mount
  • Quick Reference Guide

Configurateur d'appareil Safety Suite

Gestion rapide et précise de vos appareils détecteurs de gaz Honeywell.
Dans votre travail quotidien, vous devez vous assurer que les travailleurs se conforment à la réglementation gouvernementale et aux politiques de sécurité émises par l'entreprise. Pour demeurer conformes, les travailleurs doivent avoir en main un équipement qui a été inspecté pour la sécurité et la formation qui les certifie pour effectuer certaines tâches.

Peut-être que vous passez déjà trop de temps à effectuer des tâches administratives. Votre système actuel, probablement répétitif, encombrant ou fastidieux, peut vous empêcher de sortir de votre bureau, d'élaborer des politiques de sécurité ou de collaborer d'une autre manière avec les opérations pour améliorer votre environnement de travail.

Caractéristiques

  • Fonctionne dans un lieu de travail non connecté à Internet, donc le logiciel est accessible à tout moment et les problèmes de confidentialité des données sont minimisés
  • Un entretien réduit grâce à une gestion rationalisée du micrologiciel
  • Gagnez du temps avec un téléchargement de données en un clic pour toutes les données de l'instrument
Augmentez votre productivité
Travailleur replaçant un détecteur dans un socle de station d’accueil

Le logiciel de configuration d’appareil Safety Suite permet une gestion et un entretien rapides et précis de votre parc de détecteurs de gaz portables Honeywell.

En tant que responsable de la sécurité ou des opérations, il constitue votre outil de choix pour simplifier les rapports et rationaliser les tâches administratives. Son interface très intuitive et conviviale vous permet d'extraire toutes les données nécessaires de manière intelligente, efficace et qui fait gagner du temps. Sa technologie de pointe garantit que toutes les données sont cryptées, minimisant les menaces de confidentialité.

IC'est une solution logicielle facile à utiliser pour augmenter votre productivité.

Exemple d’onglet Historique dans le logiciel Safety Suite
Bénéfices du configurateur d'appareil Safety Suite

TLe configurateur d’appareil Safety Suite vous permet de gérer facilement vos appareils détecteurs de gaz portables et vos stations d’accueil Honeywell. Il réduit le fardeau administratif et simplifie la conformité afin que vous puissiez vous concentrer sur la sécurité des personnes.

Interface utilisateur simple et intuitive

  • Des interactions utilisateur constantes, claires et précises
  • Un minimum de formation et de temps est requis pour utiliser le logiciel
Travailleur avec ordinateur portable ouvert et affichant le logiciel Safety Suite à l’écran

Gestion simplifiée des appareils

  • Productivité accrue grâce à une meilleure abstraction des informations
  • Analyse intelligente sur les incidents grâce à un rapport d'événements centralisé
  • Easier device configuration using logical data groups and templates
  • Un entretien réduit grâce à une gestion rationalisée du micrologiciel

Gestion des utilisateurs sécurisée et flexible

  • Contrôle d'accès géré pour une sécurité accrue des données
  • Accès basé sur les rôles pour assurer la sécurité des informations
Page d’accueil du logiciel Safety Suite

Données localisées

  • Aucune dépendance vis-à-vis des réseaux ou infrastructures externes - le logiciel est accessible en tout temps
  • Fonctionne dans des lieux de travail non connectés à Internet
  • Minimise les problèmes de confidentialité des données
Exemple d’onglet Affichage de listes dans le logiciel Safety Suite
Critères d'installation

Matériel
CPU, 1.0 GHz ou mieux
Écran couleur (résolution d'au moins 1366 x 768, couleur 16 bits)
2 Go de mémoire vive
Au moins 4 Go d'espace libre sur le disque dur*
Port USB pour connexion d’instrument ou de station d'accueil
Connexion LAN pour les stations d'accueil connectées au réseau
Connexion Internet en option (pour accéder au module d'enregistrement du produit)
*Installation du logiciel uniquement. Le configurateur d'appareil Safety Suite peut nécessiter des quantités d'espace disque considérablement plus importantes pour stocker les données de l'appareil et d'autres données logicielles.

Logiciel
Windows® 7 32 bits SP1; Windows 7 64 bits SP1; Windows 10 64 bits
Microsoft® .NET Framework V4.6.1 ou plus récent (peut être installé lors de l'installation du configurateur d’appareil Safety Suite de Honeywell)

Autorisations d’utilisateur
Pendant l'installation, vous devez disposer de privilèges d'administrateur sur le PC local.
Remarque : Les privilèges d'administrateur ne sont pas requis pour exécuter le programme à partir de l’espace de travail.

Transfert de données facile
Par connexion Ethernet ou USB - du module d'accueil à l'ordinateur. Reportez-vous aux stations d’accueil individuelles pour les spécifications.

Webinaire: Les principes de base de la détection de gaz portable avec Honeywell


Les instruments de d&eacute;tection de gaz inflammables et toxiques sont g&eacute;n&eacute;ralement offerts en deux formats: d&eacute;tecteurs portables (lecture de points) et moniteurs fixes (d&eacute;tecteurs permanents). Le choix de l&rsquo;application qui convient le mieux d&eacute;pend de plusieurs facteurs. Y compris la fr&eacute;quence &agrave; laquelle le personnel acc&egrave;de &agrave; la zone, les conditions du site, si le danger est permanent ou transitoire, la fr&eacute;quence &agrave; laquelle des essais sont n&eacute;cessaires et, enfin, la disponibilit&eacute; des fonds.<br/><br/>Nous avons fait &eacute;quipe avec Honeywell pour ce court webinaire sur les principes de base de la d&eacute;tection de gaz portable, o&ugrave; nous couvrons:<br/>&bull; Caract&eacute;ristiques et dangers d&rsquo;un espace clos<br/>&bull; Les deux principales fonctions des d&eacute;tecteurs de gaz portables<br/>&bull; Les diff&eacute;rentes applications<br/>&bull; Que faire lors d&rsquo;alarme<br/>&bull; Contaminants potentiels pour les capteurs<br/>&bull; &Eacute;talonnage par rapport au test de r&eacute;sistance aux chocs... La diff&eacute;rence<br/>&bull; Utilisation d&rsquo;une station d&rsquo;accueil IntelliDox<br/>&bull; Entretien, nettoyage et service<br/>&bull; Conditions m&eacute;t&eacute;orologiques extr&ecirc;mes... Que faire?

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Honeywell DX-MAXXT IntelliDoX Docking Station for the Max XT II series.

Honeywell BW DX-CASE IntelliDoX Mobile Case, standard DX-CASE
Supports one or two IntelliDoX Docking Stations and two 34 L cylinders.




Honeywell BW DX-CASE1 IntelliDoX Mobile Case, large DX-CASE1
Supports one or two IntelliDoX Docking Stations and two 58 L cylinders.




Honeywell BW DX-FILTERS IntelliDoX Filters and Hoses Kit DX-FILTERS
For use with IntelliDoX Docking Stations.




Honeywell BW DX-COVER IntelliDoX Universal End Plate DX-COVER
For use with IntelliDoX Docking Stations.




Honeywell BW DX-ARM IntelliDoX Universal Latch Arm DX-ARM
For use with IntelliDoX Docking Stations.




Honeywell BW DX-NEST-MAXXT IntelliDoX Nest for the MaxXT II series DX-NEST-MAXXT
For use with MaxXTII Mulit-Gas Detectors.




Honeywell BW DX-VPA IntelliDoX Vehicle Power Adaptor DX-VPA
For use with IntelliDoX Docking Stations.




Honeywell BW DX-MI-KEY IntelliDoX Multi-Inlet Key DX-MI-KEY
For use with IntelliDoX Docking Stations.




Honeywell BW DX-SI-KEY IntelliDoX Single-Inlet Key DX-SI-KEY
For use with IntelliDoX Docking Stations.




Honeywell BW DX-STAND IntelliDoX Retractable Stand/Wall Mount DX-STAND
For use with IntelliDoX Docking Stations.




Poser une question sur le Honeywell DX-MAXXT IntelliDoX Docking Station for the Max XT II series

BW DX-MAXXT offre

Combines smart docking modules and device management software to provide automated instrument management for compatible detectors, helping you drive productivity, reliability, and efficiency. Place the detector in the docking module, and automatically test the gas detector and sensors while transferring data to the docking station. The IntelliDoX delivers quicker bump tests for better productivity. You can gang up to five IntelliDoX for even greater productivity, and each module can function independently, managing fleets of detectors, all simultaneously. The station is efficient when networked via Ethernet or stand-alone, transfer data with a USB drive.

Features

  • FastBump test that eliminates bottlenecks, while avoiding costly purge cycles that waste gase
  • Gangable up to five modules, each with its own LCD screen and keypad for independent operation
  • Easy to set up with no tools required
  • Easy to connect via Ethernet to a network
  • USB port to easily configure dock module settings or retrieve data without network access
  • Automated bump test and span calibration operation
  • Device management with Safety Suite Device Configurator
  • Modular nests for device changes
  • Bump testing, calibration, configuration, and record-keeping support for compatible detectors. User updatable settings:
    • Configure alarm settings
    • Display gas reading during alarm
    • Enable non-compliance indicator
    • Hibernate detector
    • Schedule bump test and calibration reminders
    • Transfer event logs
    • Time display preferences
    • Update firmware

Fast instrument management and enhanced productivity

IntelliDoX is easy to install, taking under 2 minutes from setup of a five‑module dock to the bump of your first instrument. Each module has its own operating system, LCD screen and internal pump allowing you to perform more than one operation at the same time. Whether you want to bump three detectors or calibrate others - you can get more done in less time.

Flexible configuration to meet changing needs

Configure the low and high alarm set points - plus other detector parameters - throughout the lifespan of the detector. So you can rely on your detector to always work the way you want it to.

Efficient networking and data transfer for easy record‑keeping

Use either USB or Ethernet to transfer bump tests, peak exposures and other gas‑detection data.

  • A new level of customization for device management
  • Configure alarm set points, track compliance of workers and more
  • Flexible docks and software - expandable to five modules
  • Quick and easy setup - great for turnarounds

Spécifications pour le BW DX-MAXXT

Automatic Tests Automatic bump test to verify sensor responds to target gas
Pump Flow rate: 350 ml/min (independent pump in each module)
Instrument Management System Honeywell SafetySuite
Fleet Manager II, version 4.4 or higher
External Interface 1 USB port, 1 ethernet port
Data Storage 2 GB internal
LCD Display Color Coding Yellow "TEST", Green "PASS", Red "FAIL"
Real-Time Clock Provides time and date stamp
Ratings EMC Directive 2014/30/EU
Low Voltage Directive 2014/35/EU
FCC Part 15
ICES-003 Canadian EMI
IP20
Power Supply 12 V/8.33 A ITE
Dimensions 5.4 x 14.2 x 4.3" (13.8 x 36.2 x 10.9 cm), per docking module
Weight 4.2 lbs (1.91 kg)
Cliquer ici pour toutes les spécifications du BW DX-MAXXT

Le BW DX-MAXXT comprend

  • Docking Station
  • Integrated Retractable Stand/Wall Mount
  • Quick Reference Guide

Configurateur d'appareil Safety Suite

Gestion rapide et précise de vos appareils détecteurs de gaz Honeywell.
Dans votre travail quotidien, vous devez vous assurer que les travailleurs se conforment à la réglementation gouvernementale et aux politiques de sécurité émises par l'entreprise. Pour demeurer conformes, les travailleurs doivent avoir en main un équipement qui a été inspecté pour la sécurité et la formation qui les certifie pour effectuer certaines tâches.

Peut-être que vous passez déjà trop de temps à effectuer des tâches administratives. Votre système actuel, probablement répétitif, encombrant ou fastidieux, peut vous empêcher de sortir de votre bureau, d'élaborer des politiques de sécurité ou de collaborer d'une autre manière avec les opérations pour améliorer votre environnement de travail.

Caractéristiques

  • Fonctionne dans un lieu de travail non connecté à Internet, donc le logiciel est accessible à tout moment et les problèmes de confidentialité des données sont minimisés
  • Un entretien réduit grâce à une gestion rationalisée du micrologiciel
  • Gagnez du temps avec un téléchargement de données en un clic pour toutes les données de l'instrument
Augmentez votre productivité
Travailleur replaçant un détecteur dans un socle de station d’accueil

Le logiciel de configuration d’appareil Safety Suite permet une gestion et un entretien rapides et précis de votre parc de détecteurs de gaz portables Honeywell.

En tant que responsable de la sécurité ou des opérations, il constitue votre outil de choix pour simplifier les rapports et rationaliser les tâches administratives. Son interface très intuitive et conviviale vous permet d'extraire toutes les données nécessaires de manière intelligente, efficace et qui fait gagner du temps. Sa technologie de pointe garantit que toutes les données sont cryptées, minimisant les menaces de confidentialité.

IC'est une solution logicielle facile à utiliser pour augmenter votre productivité.

Exemple d’onglet Historique dans le logiciel Safety Suite
Bénéfices du configurateur d'appareil Safety Suite

TLe configurateur d’appareil Safety Suite vous permet de gérer facilement vos appareils détecteurs de gaz portables et vos stations d’accueil Honeywell. Il réduit le fardeau administratif et simplifie la conformité afin que vous puissiez vous concentrer sur la sécurité des personnes.

Interface utilisateur simple et intuitive

  • Des interactions utilisateur constantes, claires et précises
  • Un minimum de formation et de temps est requis pour utiliser le logiciel
Travailleur avec ordinateur portable ouvert et affichant le logiciel Safety Suite à l’écran

Gestion simplifiée des appareils

  • Productivité accrue grâce à une meilleure abstraction des informations
  • Analyse intelligente sur les incidents grâce à un rapport d'événements centralisé
  • Easier device configuration using logical data groups and templates
  • Un entretien réduit grâce à une gestion rationalisée du micrologiciel

Gestion des utilisateurs sécurisée et flexible

  • Contrôle d'accès géré pour une sécurité accrue des données
  • Accès basé sur les rôles pour assurer la sécurité des informations
Page d’accueil du logiciel Safety Suite

Données localisées

  • Aucune dépendance vis-à-vis des réseaux ou infrastructures externes - le logiciel est accessible en tout temps
  • Fonctionne dans des lieux de travail non connectés à Internet
  • Minimise les problèmes de confidentialité des données
Exemple d’onglet Affichage de listes dans le logiciel Safety Suite
Critères d'installation

Matériel
CPU, 1.0 GHz ou mieux
Écran couleur (résolution d'au moins 1366 x 768, couleur 16 bits)
2 Go de mémoire vive
Au moins 4 Go d'espace libre sur le disque dur*
Port USB pour connexion d’instrument ou de station d'accueil
Connexion LAN pour les stations d'accueil connectées au réseau
Connexion Internet en option (pour accéder au module d'enregistrement du produit)
*Installation du logiciel uniquement. Le configurateur d'appareil Safety Suite peut nécessiter des quantités d'espace disque considérablement plus importantes pour stocker les données de l'appareil et d'autres données logicielles.

Logiciel
Windows® 7 32 bits SP1; Windows 7 64 bits SP1; Windows 10 64 bits
Microsoft® .NET Framework V4.6.1 ou plus récent (peut être installé lors de l'installation du configurateur d’appareil Safety Suite de Honeywell)

Autorisations d’utilisateur
Pendant l'installation, vous devez disposer de privilèges d'administrateur sur le PC local.
Remarque : Les privilèges d'administrateur ne sont pas requis pour exécuter le programme à partir de l’espace de travail.

Transfert de données facile
Par connexion Ethernet ou USB - du module d'accueil à l'ordinateur. Reportez-vous aux stations d’accueil individuelles pour les spécifications.

Webinaire: Les principes de base de la d&eacute;tection de gaz portable avec Honeywell


Les instruments de d&eacute;tection de gaz inflammables et toxiques sont g&eacute;n&eacute;ralement offerts en deux formats: d&eacute;tecteurs portables (lecture de points) et moniteurs fixes (d&eacute;tecteurs permanents). Le choix de l&rsquo;application qui convient le mieux d&eacute;pend de plusieurs facteurs. Y compris la fr&eacute;quence &agrave; laquelle le personnel acc&egrave;de &agrave; la zone, les conditions du site, si le danger est permanent ou transitoire, la fr&eacute;quence &agrave; laquelle des essais sont n&eacute;cessaires et, enfin, la disponibilit&eacute; des fonds.<br/><br/>Nous avons fait &eacute;quipe avec Honeywell pour ce court webinaire sur les principes de base de la d&eacute;tection de gaz portable, o&ugrave; nous couvrons:<br/>&bull; Caract&eacute;ristiques et dangers d&rsquo;un espace clos<br/>&bull; Les deux principales fonctions des d&eacute;tecteurs de gaz portables<br/>&bull; Les diff&eacute;rentes applications<br/>&bull; Que faire lors d&rsquo;alarme<br/>&bull; Contaminants potentiels pour les capteurs<br/>&bull; &Eacute;talonnage par rapport au test de r&eacute;sistance aux chocs... La diff&eacute;rence<br/>&bull; Utilisation d&rsquo;une station d&rsquo;accueil IntelliDox<br/>&bull; Entretien, nettoyage et service<br/>&bull; Conditions m&eacute;t&eacute;orologiques extr&ecirc;mes... Que faire?

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Honeywell DX-MAXXT IntelliDoX Docking Station for the Max XT II series.

Honeywell BW DX-CASE IntelliDoX Mobile Case, standard DX-CASE
Supports one or two IntelliDoX Docking Stations and two 34 L cylinders.




Honeywell BW DX-CASE1 IntelliDoX Mobile Case, large DX-CASE1
Supports one or two IntelliDoX Docking Stations and two 58 L cylinders.




Honeywell BW DX-FILTERS IntelliDoX Filters and Hoses Kit DX-FILTERS
For use with IntelliDoX Docking Stations.




Honeywell BW DX-COVER IntelliDoX Universal End Plate DX-COVER
For use with IntelliDoX Docking Stations.




Honeywell BW DX-ARM IntelliDoX Universal Latch Arm DX-ARM
For use with IntelliDoX Docking Stations.




Honeywell BW DX-NEST-MAXXT IntelliDoX Nest for the MaxXT II series DX-NEST-MAXXT
For use with MaxXTII Mulit-Gas Detectors.




Honeywell BW DX-VPA IntelliDoX Vehicle Power Adaptor DX-VPA
For use with IntelliDoX Docking Stations.




Honeywell BW DX-MI-KEY IntelliDoX Multi-Inlet Key DX-MI-KEY
For use with IntelliDoX Docking Stations.




Honeywell BW DX-SI-KEY IntelliDoX Single-Inlet Key DX-SI-KEY
For use with IntelliDoX Docking Stations.




Honeywell BW DX-STAND IntelliDoX Retractable Stand/Wall Mount DX-STAND
For use with IntelliDoX Docking Stations.




Poser une question sur le Honeywell DX-MAXXT IntelliDoX Docking Station for the Max XT II series

Plus de produits BW