Fluke Networks OFP2-CFP-QI OptiFiber Pro & Certifiber Pro Quad with Inspection

Modèle: OFP2-CFP-QI | CUP: 754082144687

Fluke Networks OFP2-CFP-QI OptiFiber Pro & Certifiber Pro Quad with Inspection

Modèle: OFP2-CFP-QI | CUP: 754082144687

The OFP-CFP-QI INTL OptiFiber Pro and CertiFiber Pro Quad kit with inspection is focused on reducing costs while enhancing productivity and improving network reliability. This is the non-wireless version and is available for countries where the WiFi adapter is not certified or for customers who do not wish to receive the WiFi adapter.

The OFP-CFP-QI INTL OptiFiber Pro and CertiFiber Pro Quad kit with inspection is focused on reducing costs while enhancing productivity and improving network reliability. This is the non-wireless version and is available for countries where the WiFi adapter is not certified or for customers who do not wish to receive the WiFi adapter.

Votre prix $44223.07 CAD
Disponibilité 2 à 3 semaines
Quantité

Fluke Networks OFP2-CFP-QI offre

Applications

  • Surveillance et entretien des centres de données

Spécifications pour le Fluke Networks OFP2-CFP-QI

Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible Fiber Types 50/125 µm
62.5/125 µm
Singlemode
Event Dead Zone 850 nm: 0.5 m Typical
1300 nm: 0.7 m Typical
1310 nm: 0.6 m Typical
1550 nm: 0.6 m Typical
Attenuation Dead Zone 850 nm: 2.5 m Typical
1300 nm: 4.5 m Typical
1310 nm: 3.6 m Typical
1550 nm: 3.7 m Typical
Dynamic Range 850 nm: 28 dB Typical
1300 nm: 30 dB Typical
1310 nm: 32 dB Typical
1550 nm: 30 dB Typical
Max Distance Range Setting MM: 40 km
SM: 130 km
Distance Measurement Range 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance Range 850 nm: -14 dB to -57 dB (Typical)
1300 nm: -14 dB to -62 dB (Typical)
1310 nm: -14 dB to -65dB (Typical)
1550 nm: -14 dB to -65 dB (Typical)
Sample Resolution 3 cm to 400 cm
Pulse Widths (Nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test Time (Per Wavelength) Auto setting: MM – 5 sec (Typical), SM – 10 sec (Typical)
Quick Test Setting: MM – 2 sec (Typical), SM – 5 sec (Typical)
Best Resolution Setting: MM – 2 to 180 sec M, SM – 5 to 180 sec
FaultMap Setting: MM - 2 sec (Typical), MM - 180 sec (Max), SM - 10 sec (Typical), SM - 180 sec (Max)
DataCenter OTDR Setting: MM – 1 sec (Typical at 850 nm) MM – 7 sec (Max), SM – 20 sec (Typical) SM – 40 sec (Max)
Manual Setting: -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
FiberInspector Probe
Magnification ~200X with OptiFiber Pro Display
Light Source Blue LED
Power Source Versiv Mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum Detectable Particle Size 0.5 µm
Dimensions Approximately 6.75" x 1.5" (1175 mm x 35 mm) Without Adapter Tip
Weight 200 g
Temperature Range Operating: 32 to 122°F (0 to +50°C)
Storage: -4 to +158°F (-20 to +70°C)
Certifications CE (when used with the mainframe)
VFL
On/Off Control Mechanical switch and a button on the touch screen
Output Power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating Wavelength 650 nm Nominal
Spectral Width (RMS) ±3 nm
Output Modes Continuous Wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter 2.5 mm Universal
Laser Safety (Classification) Class II CDRH Complies to EN 60825-2
Environmental specifications
Operating temperature* -10 to 45°C
Storage Temperature -10 to +60°C
Operating Altitude 4,000 m (13,123 ft)
3,200 m (10,500 ft) with AC Adapter
Storage Altitude 12,000 m
EMC EN 61326-1
General Specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 x 5.25 x 11.0" ( 6.67 x 13.33 x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery Life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time Tester Off: Four hours to charge from 10% to 90% capacity
Tester On: Six hours to charge from 10% to 90% capacity

Le Fluke Networks OFP2-CFP-QI comprend

  • Fluke Networks OFP2-CFP-QI OptiFiber Pro & Certifiber Pro Quad with Inspection

Poser une question sur le Fluke Networks OFP2-CFP-QI OptiFiber Pro & Certifiber Pro Quad with Inspection

Fluke Networks OFP2-CFP-QI offre

Applications

  • Surveillance et entretien des centres de données

Spécifications pour le Fluke Networks OFP2-CFP-QI

Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible Fiber Types 50/125 µm
62.5/125 µm
Singlemode
Event Dead Zone 850 nm: 0.5 m Typical
1300 nm: 0.7 m Typical
1310 nm: 0.6 m Typical
1550 nm: 0.6 m Typical
Attenuation Dead Zone 850 nm: 2.5 m Typical
1300 nm: 4.5 m Typical
1310 nm: 3.6 m Typical
1550 nm: 3.7 m Typical
Dynamic Range 850 nm: 28 dB Typical
1300 nm: 30 dB Typical
1310 nm: 32 dB Typical
1550 nm: 30 dB Typical
Max Distance Range Setting MM: 40 km
SM: 130 km
Distance Measurement Range 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance Range 850 nm: -14 dB to -57 dB (Typical)
1300 nm: -14 dB to -62 dB (Typical)
1310 nm: -14 dB to -65dB (Typical)
1550 nm: -14 dB to -65 dB (Typical)
Sample Resolution 3 cm to 400 cm
Pulse Widths (Nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test Time (Per Wavelength) Auto setting: MM – 5 sec (Typical), SM – 10 sec (Typical)
Quick Test Setting: MM – 2 sec (Typical), SM – 5 sec (Typical)
Best Resolution Setting: MM – 2 to 180 sec M, SM – 5 to 180 sec
FaultMap Setting: MM - 2 sec (Typical), MM - 180 sec (Max), SM - 10 sec (Typical), SM - 180 sec (Max)
DataCenter OTDR Setting: MM – 1 sec (Typical at 850 nm) MM – 7 sec (Max), SM – 20 sec (Typical) SM – 40 sec (Max)
Manual Setting: -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
FiberInspector Probe
Magnification ~200X with OptiFiber Pro Display
Light Source Blue LED
Power Source Versiv Mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum Detectable Particle Size 0.5 µm
Dimensions Approximately 6.75" x 1.5" (1175 mm x 35 mm) Without Adapter Tip
Weight 200 g
Temperature Range Operating: 32 to 122°F (0 to +50°C)
Storage: -4 to +158°F (-20 to +70°C)
Certifications CE (when used with the mainframe)
VFL
On/Off Control Mechanical switch and a button on the touch screen
Output Power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating Wavelength 650 nm Nominal
Spectral Width (RMS) ±3 nm
Output Modes Continuous Wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter 2.5 mm Universal
Laser Safety (Classification) Class II CDRH Complies to EN 60825-2
Environmental specifications
Operating temperature* -10 to 45°C
Storage Temperature -10 to +60°C
Operating Altitude 4,000 m (13,123 ft)
3,200 m (10,500 ft) with AC Adapter
Storage Altitude 12,000 m
EMC EN 61326-1
General Specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 x 5.25 x 11.0" ( 6.67 x 13.33 x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery Life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time Tester Off: Four hours to charge from 10% to 90% capacity
Tester On: Six hours to charge from 10% to 90% capacity