Fluke Networks OFP-100-Q-W INT OptiFiber Pro Quad OTDR with WiFi

Modèle: OFP-100-Q-W INT | CUP: 754082140863

Fluke Networks OFP-100-Q-W INT OptiFiber Pro Quad OTDR with WiFi

Modèle: OFP-100-Q-W INT | CUP: 754082140863

The OFP-100-Q-W INT Pro Quad OTDR kit is focused on reducing costs while enhancing productivity and improving network reliability. This is the wireless version and includes a WiFi adapter for LinkWare Live.

The OFP-100-Q-W INT Pro Quad OTDR kit is focused on reducing costs while enhancing productivity and improving network reliability. This is the wireless version and includes a WiFi adapter for LinkWare Live.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :

Fluke Networks OFP2-100-Q OptiFiber Pro Quad OTDR-

Fluke Networks OFP2-100-Q OptiFiber Pro Quad OTDR

Modèle: OFP2-100-Q

L'ensemble OTDR OFP-100-Q/INTL Pro Quad est axé sur la réduction des coûts tout en augmentant la productivité et en améliorant la fiabilité du réseau. Il s'agit de la version non sans fil, disponible pour les pays où l'adaptateur WiFi n'est pas certifié ou pour les clients qui ne souhaitent pas recevoir l'adaptateur WiFi.


Fluke Networks OFP-100-Q-W INT offre

The OptiFiber® Pro OTDR elevates fiber optic testing with the industry's only smartphone interface that turns a technician into a fiber expert. The DataCenter OTDR configuration eliminates uncertainty and errors that occur when testing data center fiber. Its ultra-short dead zones enable testing of fiber patchcords in virtualized data centers. These capabilities, plus the fastest-in-the-industry trace times, make the OptiFiber Pro OTDR a must-have tool.

Caractéristiques

  • First OTDR with a smartphone user-interface
  • Industry's shortest event and attenuation dead zones
  • Accelerate fiber certification with the fastest set-up and trace times
  • SmartLoop™ technology enables the testing of two fibers in a single test eliminating the need to travel to the far end of the connection to perform tests.
  • Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Instantaneous bi-directional averaging results included at no charge
  • Improve resource utilization with custom configurations for projects and users
  • Simplify use with "DataCenter OTDR™" mode and EventMap™ view

Spécifications pour le Fluke Networks OFP-100-Q-W INT

Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible Fiber Types 50/125 µm
62.5/125 µm
Singlemode
Event Dead Zone 850 nm: 0.5 m Typical
1300 nm: 0.7 m Typical
1310 nm: 0.6 m Typical
1550 nm: 0.6 m Typical
Attenuation Dead Zone 850 nm: 2.5 m Typical
1300 nm: 4.5 m Typical
1310 nm: 3.6 m Typical
1550 nm: 3.7 m Typical
Dynamic Range 850 nm: 28 dB Typical
1300 nm: 30 dB Typical
1310 nm: 32 dB Typical
1550 nm: 30 dB Typical
Max Distance Range Setting MM: 40 km
SM: 130 km
Distance Measurement Range 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance Range 850 nm: -14 dB to -57 dB (Typical)
1300 nm: -14 dB to -62 dB (Typical)
1310 nm: -14 dB to -65dB (Typical)
1550 nm: -14 dB to -65 dB (Typical)
Sample Resolution 3 cm to 400 cm
Pulse Widths (Nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test Time (Per Wavelength) Auto setting: MM – 5 sec (Typical), SM – 10 sec (Typical)
Quick Test Setting: MM – 2 sec (Typical), SM – 5 sec (Typical)
Best Resolution Setting: MM – 2 to 180 sec M, SM – 5 to 180 sec
FaultMap Setting: MM - 2 sec (Typical), MM - 180 sec (Max), SM - 10 sec (Typical), SM - 180 sec (Max)
DataCenter OTDR Setting: MM – 1 sec (Typical at 850 nm) MM – 7 sec (Max), SM – 20 sec (Typical) SM – 40 sec (Max)
Manual Setting: -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
FiberInspector Probe
Magnification ~200X with OptiFiber Pro Display
Light Source Blue LED
Power Source Versiv Mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum Detectable Particle Size 0.5 µm
Dimensions Approximately 6.75" x 1.5" (1175 mm x 35 mm) Without Adapter Tip
Weight 200 g
Temperature Range Operating: 32 to 122°F (0 to +50°C)
Storage: -4 to +158°F (-20 to +70°C)
Certifications CE (when used with the mainframe)
VFL
On/Off Control Mechanical switch and a button on the touch screen
Output Power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating Wavelength 650 nm Nominal
Spectral Width (RMS) ±3 nm
Output Modes Continuous Wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter 2.5 mm Universal
Laser Safety (Classification) Class II CDRH Complies to EN 60825-2
Environmental specifications
Operating temperature* -10 to 45°C
Storage Temperature -10 to +60°C
Operating Altitude 4,000 m (13,123 ft)
3,200 m (10,500 ft) with AC Adapter
Storage Altitude 12,000 m
EMC EN 61326-1
General Specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 x 5.25 x 11.0" ( 6.67 x 13.33 x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery Life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time Tester Off: Four hours to charge from 10% to 90% capacity
Tester On: Six hours to charge from 10% to 90% capacity

Le Fluke Networks OFP-100-Q-W INT comprend

  • Versiv Mainframe
  • OptiFiber Pro Quad OTDR Module
  • Shoulder Strap
  • Carrying Case
  • USB Interface Cable
  • Versiv Open Source Software CD
  • AC Charger
  • WiFi Adapter
  • Getting Started Guides

Poser une question sur le Fluke Networks OFP-100-Q-W INT OptiFiber Pro Quad OTDR with WiFi

Fluke Networks OFP-100-Q-W INT offre

The OptiFiber® Pro OTDR elevates fiber optic testing with the industry's only smartphone interface that turns a technician into a fiber expert. The DataCenter OTDR configuration eliminates uncertainty and errors that occur when testing data center fiber. Its ultra-short dead zones enable testing of fiber patchcords in virtualized data centers. These capabilities, plus the fastest-in-the-industry trace times, make the OptiFiber Pro OTDR a must-have tool.

Caractéristiques

  • First OTDR with a smartphone user-interface
  • Industry's shortest event and attenuation dead zones
  • Accelerate fiber certification with the fastest set-up and trace times
  • SmartLoop™ technology enables the testing of two fibers in a single test eliminating the need to travel to the far end of the connection to perform tests.
  • Versiv™ modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
  • Instantaneous bi-directional averaging results included at no charge
  • Improve resource utilization with custom configurations for projects and users
  • Simplify use with "DataCenter OTDR™" mode and EventMap™ view

Spécifications pour le Fluke Networks OFP-100-Q-W INT

Wavelengths 850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible Fiber Types 50/125 µm
62.5/125 µm
Singlemode
Event Dead Zone 850 nm: 0.5 m Typical
1300 nm: 0.7 m Typical
1310 nm: 0.6 m Typical
1550 nm: 0.6 m Typical
Attenuation Dead Zone 850 nm: 2.5 m Typical
1300 nm: 4.5 m Typical
1310 nm: 3.6 m Typical
1550 nm: 3.7 m Typical
Dynamic Range 850 nm: 28 dB Typical
1300 nm: 30 dB Typical
1310 nm: 32 dB Typical
1550 nm: 30 dB Typical
Max Distance Range Setting MM: 40 km
SM: 130 km
Distance Measurement Range 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance Range 850 nm: -14 dB to -57 dB (Typical)
1300 nm: -14 dB to -62 dB (Typical)
1310 nm: -14 dB to -65dB (Typical)
1550 nm: -14 dB to -65 dB (Typical)
Sample Resolution 3 cm to 400 cm
Pulse Widths (Nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test Time (Per Wavelength) Auto setting: MM – 5 sec (Typical), SM – 10 sec (Typical)
Quick Test Setting: MM – 2 sec (Typical), SM – 5 sec (Typical)
Best Resolution Setting: MM – 2 to 180 sec M, SM – 5 to 180 sec
FaultMap Setting: MM - 2 sec (Typical), MM - 180 sec (Max), SM - 10 sec (Typical), SM - 180 sec (Max)
DataCenter OTDR Setting: MM – 1 sec (Typical at 850 nm) MM – 7 sec (Max), SM – 20 sec (Typical) SM – 40 sec (Max)
Manual Setting: -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
FiberInspector Probe
Magnification ~200X with OptiFiber Pro Display
Light Source Blue LED
Power Source Versiv Mainframe
Field of View (FOV) Horizontal: 425 µm
Vertical: 320 µm
Minimum Detectable Particle Size 0.5 µm
Dimensions Approximately 6.75" x 1.5" (1175 mm x 35 mm) Without Adapter Tip
Weight 200 g
Temperature Range Operating: 32 to 122°F (0 to +50°C)
Storage: -4 to +158°F (-20 to +70°C)
Certifications CE (when used with the mainframe)
VFL
On/Off Control Mechanical switch and a button on the touch screen
Output Power 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating Wavelength 650 nm Nominal
Spectral Width (RMS) ±3 nm
Output Modes Continuous Wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter 2.5 mm Universal
Laser Safety (Classification) Class II CDRH Complies to EN 60825-2
Environmental specifications
Operating temperature* -10 to 45°C
Storage Temperature -10 to +60°C
Operating Altitude 4,000 m (13,123 ft)
3,200 m (10,500 ft) with AC Adapter
Storage Altitude 12,000 m
EMC EN 61326-1
General Specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 x 5.25 x 11.0" ( 6.67 x 13.33 x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery Life Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge Time Tester Off: Four hours to charge from 10% to 90% capacity
Tester On: Six hours to charge from 10% to 90% capacity

Le Fluke Networks OFP-100-Q-W INT comprend

  • Versiv Mainframe
  • OptiFiber Pro Quad OTDR Module
  • Shoulder Strap
  • Carrying Case
  • USB Interface Cable
  • Versiv Open Source Software CD
  • AC Charger
  • WiFi Adapter
  • Getting Started Guides

Poser une question sur le Fluke Networks OFP-100-Q-W INT OptiFiber Pro Quad OTDR with WiFi

Plus de produits Fluke Networks