Fluke Networks DTX-CLT CertiFiber Series

Fluke Networks DTX-CLT CertiFiber Series

Because present-day enterprise data networks increasingly rely on fiber optic cabling, it is more important than ever for installers and network owners to use Optical Loss Test Sets (OLTS) certify and document that their fiber links meet established industry standards to protect against network downtime and lost revenue.

Because present-day enterprise data networks increasingly rely on fiber optic cabling, it is more important than ever for installers and network owners to use Optical Loss Test Sets (OLTS) certify and document that their fiber links meet established industry standards to protect against network downtime and lost revenue.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:

Visitez notre catégorie Trousses de formation et d’essai pour trouver des produits similaires.

Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:


Fluke Networks DTX-CERTIFIBER offre

About the CertiFiber Series

Features


Fiber Certfication

Basic (Tier1) fiber certification

DTX Fiber Modules provide a Basic (Tier 1) fiber certification solution - loss, length and polarity. Validate fiber link performance per industry standards. Measure optical loss at multiple wavelengths, measure fiber length and verify polarity. You can test two fibers in both directions at both wavelengths with incredible speed without swapping main and remote units, a capability only available from Fluke Networks. Interchangeable connector adapters allow reference and test connections that meet TIA/ISO standards for most SFF (small form factor) fiber connectors.

Unlike competitive fiber adapters which measure length and two loss measurements per Autotest, DTX is the only fiber test solution that measures length and four loss measurements per Autotest - all in about 12 seconds. With DTX Fiber Modules, you can speed through fiber testing five times faster than the competition.


LinkWare Reports

Save time managing results with LinkWare Cable Test Management Software

LinkWare is also available free from our web site. Once your work is done, you can give this powerful application to your customers so they can have instant access to the data electronically. You can also print test results or you can export the data as an Adobe Portable Document Format (PDF).

Extensive data management capabilities with LinkWare:

  • Manage copper and fiber test results with a single software application that supports Fluke Networks' entire line of cable testers
  • Deliver professional, customized, graphical reports in a common format for all Fluke Networks cable testers
  • Ensure standards compliance with the ability to configure and print TIA 606-A documentation
  • New drag and drop feature makes it easier to manage and organize multiple projects
  • Count on compatibility with major CMS (cable management software) applications
  • Increase productivity with simple user interface and time-saving features with LinkWare, the world's preferred cable test management software

LinkWare Software prints professional, graphical reports with color graphs depicting the measured test parameters. You can choose which parameters to print and the order in which graphs appear. Reports can also be customized with your company logo.

New LinkWare Stats option provides a graphical analysis of your entire cable plant

LinkWare now supports LinkWare Stats, a new automated statistical report option that allows you to move above and beyond the page-per-link report and see your entire cabling infrastructure. It analyzes and transforms LinkWare test results data into charts and diagrams that reveal your cabling plant performance; this report summarizes your entire cabling infrastructure in a compact, graphical format that makes it easy to verify margins and to spot anomalies.

See what LinkWare Stats can do with your data - A free demo version of LinkWare Stats is included with every copy of LinkWare.

Because present-day enterprise data networks increasingly rely on fiber optic cabling, it is more important than ever for installers and network owners to use Optical Loss Test Sets (OLTS) certify and document that their fiber links meet established industry standards to protect against network downtime and lost revenue.

The Fluke Networks DTX-CLT CertiFiber® OLTS enables you to easily and accurately certify two fibers concurrently over two wavelengths according to custom requirements or established industry specifications. Quickly and efficiently conduct troubleshooting with a convenient integrated Visual Fault Locator (VFL).

The DTX-CLT CertiFiber OLTS does not certify copper cable.

Spécifications pour le Fluke Networks DTX-CERTIFIBER

Optical Specifications (23°C)
Input (Meter) connectors Removeable adapter on fiber optic power meter (input port). Removable SC adapter standard with product. Optional removable adapters: LC, ST and FC
Length measurement DTX-MFM2: < 5,000 m of 62.5 or 50 µm fiber<br> DTX-GFM2: < 5,000 m of 62.5 or 50 µm fiber<br> DTX-SFM2: < 10,000 m of 9 µm singlemode fiber
Output (Source) connectors Fixed SC adapter
Source type and nominal wavelength DTX-MFM2: 850 nm LED and 1300 nm LED
DTX-GFM2: 850 nm VCSEL and 1310 nm FP laser
DTX-SFM2: 1310 nm FP laser and 1550 nm FP laser
Source power DTX-MFM2: > -20 dBm, DTX-SFM2: > -7 dBm
Power meter type InGaAs detector
Power measurement range 0 to -60 dBm (1310 nm and 1550 nm)
0 to -52 dBm (850 nm)
VFL Specifications (23°C)
Laser type and nominal wavelength Class II CDRH, 650 nm
Output modes Continuous wave and flashing mode
Connector adapter 2.5 mm universal
Environmental Specifications
Operating temperature 0°C to 40°C
Storage temperature -20°C to 60°C
Safety CE, CSA, EN 61010-1
General Specifications
Dimensions (L x W x D), nominal 4.2” x 3.0” x 1.1” (106 mm x 76 mm x 28 mm)
Weight, nominal 0.31 lb (0.14 kg)

Le Fluke Networks DTX-CERTIFIBER comprend

  • Fluke Networks DTX-CLT CertiFiber Series

Poser une question sur le Fluke Networks DTX-CLT CertiFiber Series

Fluke Networks DTX-CERTIFIBER offre

About the CertiFiber Series

Features


Fiber Certfication

Basic (Tier1) fiber certification

DTX Fiber Modules provide a Basic (Tier 1) fiber certification solution - loss, length and polarity. Validate fiber link performance per industry standards. Measure optical loss at multiple wavelengths, measure fiber length and verify polarity. You can test two fibers in both directions at both wavelengths with incredible speed without swapping main and remote units, a capability only available from Fluke Networks. Interchangeable connector adapters allow reference and test connections that meet TIA/ISO standards for most SFF (small form factor) fiber connectors.

Unlike competitive fiber adapters which measure length and two loss measurements per Autotest, DTX is the only fiber test solution that measures length and four loss measurements per Autotest - all in about 12 seconds. With DTX Fiber Modules, you can speed through fiber testing five times faster than the competition.


LinkWare Reports

Save time managing results with LinkWare Cable Test Management Software

LinkWare is also available free from our web site. Once your work is done, you can give this powerful application to your customers so they can have instant access to the data electronically. You can also print test results or you can export the data as an Adobe Portable Document Format (PDF).

Extensive data management capabilities with LinkWare:

  • Manage copper and fiber test results with a single software application that supports Fluke Networks' entire line of cable testers
  • Deliver professional, customized, graphical reports in a common format for all Fluke Networks cable testers
  • Ensure standards compliance with the ability to configure and print TIA 606-A documentation
  • New drag and drop feature makes it easier to manage and organize multiple projects
  • Count on compatibility with major CMS (cable management software) applications
  • Increase productivity with simple user interface and time-saving features with LinkWare, the world's preferred cable test management software

LinkWare Software prints professional, graphical reports with color graphs depicting the measured test parameters. You can choose which parameters to print and the order in which graphs appear. Reports can also be customized with your company logo.

New LinkWare Stats option provides a graphical analysis of your entire cable plant

LinkWare now supports LinkWare Stats, a new automated statistical report option that allows you to move above and beyond the page-per-link report and see your entire cabling infrastructure. It analyzes and transforms LinkWare test results data into charts and diagrams that reveal your cabling plant performance; this report summarizes your entire cabling infrastructure in a compact, graphical format that makes it easy to verify margins and to spot anomalies.

See what LinkWare Stats can do with your data - A free demo version of LinkWare Stats is included with every copy of LinkWare.

Because present-day enterprise data networks increasingly rely on fiber optic cabling, it is more important than ever for installers and network owners to use Optical Loss Test Sets (OLTS) certify and document that their fiber links meet established industry standards to protect against network downtime and lost revenue.

The Fluke Networks DTX-CLT CertiFiber® OLTS enables you to easily and accurately certify two fibers concurrently over two wavelengths according to custom requirements or established industry specifications. Quickly and efficiently conduct troubleshooting with a convenient integrated Visual Fault Locator (VFL).

The DTX-CLT CertiFiber OLTS does not certify copper cable.

Spécifications pour le Fluke Networks DTX-CERTIFIBER

Optical Specifications (23°C)
Input (Meter) connectors Removeable adapter on fiber optic power meter (input port). Removable SC adapter standard with product. Optional removable adapters: LC, ST and FC
Length measurement DTX-MFM2: < 5,000 m of 62.5 or 50 µm fiber<br> DTX-GFM2: < 5,000 m of 62.5 or 50 µm fiber<br> DTX-SFM2: < 10,000 m of 9 µm singlemode fiber
Output (Source) connectors Fixed SC adapter
Source type and nominal wavelength DTX-MFM2: 850 nm LED and 1300 nm LED
DTX-GFM2: 850 nm VCSEL and 1310 nm FP laser
DTX-SFM2: 1310 nm FP laser and 1550 nm FP laser
Source power DTX-MFM2: > -20 dBm, DTX-SFM2: > -7 dBm
Power meter type InGaAs detector
Power measurement range 0 to -60 dBm (1310 nm and 1550 nm)
0 to -52 dBm (850 nm)
VFL Specifications (23°C)
Laser type and nominal wavelength Class II CDRH, 650 nm
Output modes Continuous wave and flashing mode
Connector adapter 2.5 mm universal
Environmental Specifications
Operating temperature 0°C to 40°C
Storage temperature -20°C to 60°C
Safety CE, CSA, EN 61010-1
General Specifications
Dimensions (L x W x D), nominal 4.2” x 3.0” x 1.1” (106 mm x 76 mm x 28 mm)
Weight, nominal 0.31 lb (0.14 kg)

Le Fluke Networks DTX-CERTIFIBER comprend

  • Fluke Networks DTX-CLT CertiFiber Series

Poser une question sur le Fluke Networks DTX-CLT CertiFiber Series

Plus de produits Fluke Networks