Versiv modular design supports copper certification, fiber loss, OTDR testing and Wi-Fi analysis. Unmatched speed for Cat 6A, Class FA and all current standards. ProjX System manages job requirements making sure tests are completed correctly.
Versiv modular design supports copper certification, fiber loss, OTDR testing and Wi-Fi analysis. Unmatched speed for Cat 6A, Class FA and all current standards. ProjX System manages job requirements making sure tests are completed correctly.
Discontinué!
Ce produit a été discontinué et n’est plus disponible.
Il n’y a pas de remplacement direct, mais nous vous recommandons:
Vous ne trouvez pas ce que vous cherchez? Nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin.
Applications
| Cable Types | |
| Shielded and Unshielded Pair LAN Cabling | TIA Category 3, 4, 5, 5e, 6, 6A: 100 Ω ISO/IEC Class C, D, E, EA, F, and FA: 100 Ω and 120 Ω |
| Standard Link Interface Adapters | |
| Permanent Link Adapters | Plug type: shielded RJ45 Optional Plug type: Tera |
| Channel Adapters | Jack type: shielded RJ45 Optional Jack type: Tera |
| Test Standards | |
| TIA | Category 3, 4, 5, 5e, 6, 6A per TIA 568-C.2 |
| ISO/IEC | Class C and D, E, Ea, F, FA certification per ISO/IEC 11801:2002 and amendments |
| Maximum Frequency | 1200 MHz |
| General Specifications | |
| Speed of Autotest | Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds Full 2-way Autotest of Category 6A/Class EA: 10 seconds |
| Support Test Parameters (The selected test standard determines the test parameters and the frequency range of the tests) | Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F) |
| Input Protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
| Display | 5.7 in LCD display with a projected capacitance touchscreen |
| Case | High impact plastic with show absorbing overmold |
| Dimensions | Main Versiv unit with DSX-5000 module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
| Weight | Main Versiv unit with DSX-5000 module and battery installed: 3 lbs, 5oz (1.28 kg) |
| Main unit and remote | Lithium ion battery pack, 7.2 V |
| Typical battery life | 8 hours |
| Charge time* | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity. |
| Languages supported | English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese |
| Calibration | Service center calibration period is 1 year |
| Environment Specifications | |
| Operating Temperature | 32 to 113°F (0 to 45°C) |
| Storage Temperature | -4 to 122°F (-20 to 50°C) |
| Operating relative humidity | 0% to 90%, 32 to 95°F (0 to 35°C) 0% to 70%, 95 to 113°F (35 to 45°C) |
| Vibration | Random, 2 g, 5 Hz-500 Hz |
| Shock | 1 m drop test with and without module and adapter |
| Safety | CSA 22.2 No. 61010, IEC 61010-1 2nd Edition + Amendments 1, 2 |
| Operating altitude | 13,123 ft (4,000 m) |
| EMC | EN 61326-1 |
| Performance Specifications | |
| Category 6A/Class EA test modes (or lower link categories) | DSX-5000 CableAnalyzer modules exceed with Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1. |
| Class FA test modes | DSX-5000 CableAnalyzer modules exceed Level V requirements as in the draft 4th edition of IEC 61935-1. |
| Length of Twisted Pair Cabling Without Remote | |
| Range | 800 m (2600 ft) |
| Resolution | 0.1 m or 1 ft |
| Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m |
| Range | 150 m (490 ft) |
| Resolution | 0.1 m or 1 ft |
| Accuracy | ± (0.3 m + 2 %) |
| Propagation Delay Without Remote | |
| Range | 4000 ns |
| Resolution | 1 ns |
| Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns |
| Propagation Delay With Remote | |
| Range | 750 ns |
| Resolution | 1 ns |
| Accuracy | ± (2 ns + 2 %) |
| Delay Skew | |
| Range | 0 ns to 100 ns |
| Resolution | 1 ns |
| Accuracy | ± 10 ns |
| DC Loop Resistance Test | |
| Range | 0 Ω to 540 Ω |
| Resolution | 0.1 Ω |
| Accuracy | ± (1 Ω + 1 %) |
| Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke Networks DSX-5000 Cable Analyzer.
| Cable Types | |
| Shielded and Unshielded Pair LAN Cabling | TIA Category 3, 4, 5, 5e, 6, 6A: 100 Ω ISO/IEC Class C, D, E, EA, F, and FA: 100 Ω and 120 Ω |
| Standard Link Interface Adapters | |
| Permanent Link Adapters | Plug type: shielded RJ45 Optional Plug type: Tera |
| Channel Adapters | Jack type: shielded RJ45 Optional Jack type: Tera |
| Test Standards | |
| TIA | Category 3, 4, 5, 5e, 6, 6A per TIA 568-C.2 |
| ISO/IEC | Class C and D, E, Ea, F, FA certification per ISO/IEC 11801:2002 and amendments |
| Maximum Frequency | 1200 MHz |
| General Specifications | |
| Speed of Autotest | Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds Full 2-way Autotest of Category 6A/Class EA: 10 seconds |
| Support Test Parameters (The selected test standard determines the test parameters and the frequency range of the tests) | Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F) |
| Input Protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
| Display | 5.7 in LCD display with a projected capacitance touchscreen |
| Case | High impact plastic with show absorbing overmold |
| Dimensions | Main Versiv unit with DSX-5000 module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
| Weight | Main Versiv unit with DSX-5000 module and battery installed: 3 lbs, 5oz (1.28 kg) |
| Main unit and remote | Lithium ion battery pack, 7.2 V |
| Typical battery life | 8 hours |
| Charge time* | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity. |
| Languages supported | English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese |
| Calibration | Service center calibration period is 1 year |
| Environment Specifications | |
| Operating Temperature | 32 to 113°F (0 to 45°C) |
| Storage Temperature | -4 to 122°F (-20 to 50°C) |
| Operating relative humidity | 0% to 90%, 32 to 95°F (0 to 35°C) 0% to 70%, 95 to 113°F (35 to 45°C) |
| Vibration | Random, 2 g, 5 Hz-500 Hz |
| Shock | 1 m drop test with and without module and adapter |
| Safety | CSA 22.2 No. 61010, IEC 61010-1 2nd Edition + Amendments 1, 2 |
| Operating altitude | 13,123 ft (4,000 m) |
| EMC | EN 61326-1 |
| Performance Specifications | |
| Category 6A/Class EA test modes (or lower link categories) | DSX-5000 CableAnalyzer modules exceed with Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1. |
| Class FA test modes | DSX-5000 CableAnalyzer modules exceed Level V requirements as in the draft 4th edition of IEC 61935-1. |
| Length of Twisted Pair Cabling Without Remote | |
| Range | 800 m (2600 ft) |
| Resolution | 0.1 m or 1 ft |
| Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m |
| Range | 150 m (490 ft) |
| Resolution | 0.1 m or 1 ft |
| Accuracy | ± (0.3 m + 2 %) |
| Propagation Delay Without Remote | |
| Range | 4000 ns |
| Resolution | 1 ns |
| Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns |
| Propagation Delay With Remote | |
| Range | 750 ns |
| Resolution | 1 ns |
| Accuracy | ± (2 ns + 2 %) |
| Delay Skew | |
| Range | 0 ns to 100 ns |
| Resolution | 1 ns |
| Accuracy | ± 10 ns |
| DC Loop Resistance Test | |
| Range | 0 Ω to 540 Ω |
| Resolution | 0.1 Ω |
| Accuracy | ± (1 Ω + 1 %) |
| Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke Networks DSX-5000 Cable Analyzer.