Eurotherm WV118-2000.V1 DC Powered RTD Input Limit Alarm, -328 to 1112°F, 2 SPDT relays

Modèle: WV118-2000.V1

Eurotherm WV118-2000.V1 DC Powered RTD Input Limit Alarm, -328 to 1112°F, 2 SPDT relays

Modèle: WV118-2000.V1

Configurable as a single or dual setpoint alarm, this DC-powered RTD input limit alarm provides relay contact closures at a preset temperature level. In addition, this alarm features dual setpoints and two contact closures, and the input type and alarm functions are field configurable.

Configurable as a single or dual setpoint alarm, this DC-powered RTD input limit alarm provides relay contact closures at a preset temperature level. In addition, this alarm features dual setpoints and two contact closures, and the input type and alarm functions are field configurable.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n'y a aucune option de remplacement.

Nous pouvons vous aider à trouver ce dont vous avez besoin:


Eurotherm WV118-2000.V1 offre

Accurate and stable, this DC-powered RTD input limit alarm features two standard non-latching SPDT relays. In addition, this alarm features high or low trips and failsafe or non-failsafe operation.

Caractéristiques

  • Programmable high or low, failsafe or non-failsafe
  • Improved accuracy
  • Adjustable deadband
  • Bussed power with plug-in power clips
  • Removable terminals for easy service
  • TouchCAL for best stability and accuracy
  • RoHS compliant
  • LED trip and input indicators
  • Supports two-wire and three-wire RTDs

Spécifications pour le Eurotherm WV118-2000.V1

Inputs Sensor types: Pt100 0.00385, Pt100 0.00392, Cu10
Sensor Connection Two-wire or three-wire
Ranges Pt100 RTDs: -32 to 1112°F (-200 to 600°C), Alpha: 0.00385
Cu10 RTDs: -328 to 500°F (-200 to 260°C)
RTD Excitation Pt100: 0.45 mA, maximum
Cu10: 5.0 mA, maximum
Lead Wire Resistance: 40% of the base sensor resistance maximum or 100 Ω (whichever is less)
Effect: Changing from 0 Ω lead resistance (each lead) to maximum allowed lead resistance: Error <1% of largest span PT and Cu ranges; -32 to 1112°F (-200 to 600°C) for Pt and -328 to 500°F (-200 to 260°C) for Cu
Pushbutton Adjustment Effective zero offset: >95%
(Inputs >10 mV): Effective span turn down: >95%
Local Range Selection By DIP switch
Response Time Dynamic deadband: Relay status will change when proper setpoint/process condition exists for 100 ms
Normal mode: <250 ms (analog filtering)
Setpoint Effectivity Setpoints are adjustable (by pushbutton) over 100% of the selected input span
Repeatability ±0.05% of FS, ±1°C (constant temp)
Relay Contacts 2 SPDT (2 form C) relays, 1 relay per setpoint
Current rating (general use) 120 V AC: 5 A; 240 V AC: 2 A; 28 V DC: 5 A
Material Gold flash over silver alloy
Electrical Life 105 operations at rated load
Stability ±100 ppm of full scale/°C (±0.01%/°C)
Common Mode Rejection 120 dB at DC, >90 dB at 60 Hz, or better
Isolation >1800 V DC or peak AC between input, output and power
ESD Susceptibility Capable of meeting IEC 801-2 level 3 (8 kV)
Humidity (non-condensing) Operating: 15 to 95% RH at 113°F (45°C)
Soak: 90% RH for 24 hours at 140°F (60°C)
Temperature Operating: 32 to 140°F (0 to 60°C)
Storage: -13 to 185°F (-25 to 85°C)
Host Module Interface IR link, same specs as phase 1 modules
Agency Approvals (EMC and Safety) UL recognized per standard UL508 (File No.E99775)
CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (Input <75 V DC, only)
RoHS compliant
Power 9 to 30 V DC, 1 W typical, 2 W maximum
Dimensions 4.39 x 3.54 x 0.69" (111.6 x 90 x 17.5 mm)
DIN rail case

Le Eurotherm WV118-2000.V1 comprend

  • Eurotherm WV118-2000.V1 DC Powered RTD Input Limit Alarm, -328 to 1112°F, 2 SPDT relays

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Eurotherm WV118-2000.V1 DC Powered RTD Input Limit Alarm, -328 to 1112°F, 2 SPDT relays.

Eurotherm H910-0024 DIN-Rail Mount Power Supply, 1000 mA at 24 V DC, 115 to 230 V AC H910-0024
Ideal for use with 24 V DC-powered products, this DIN-rail mount power supply supplies up to 1000 mA at 24 V DC. In addition, this power supply features an LED power indicator, input fuse protection, and output DC short circuit protection.




Eurotherm H915-0001-1 DIN-Rail Mount Power Supply, 2300 mA at 24 V DC, 85 to 265 V AC H915-0001-1
Ideal for use with 24 V DC-powered products, this DIN-rail mount power supply supplies up to 2300 mA at 24 V DC and has multiple wire terminal connections. In addition, this power supply features an LED power indicator, input fuse protection, and output DC short circuit protection.




Eurotherm MB03-0000 End Bracket for the MD03 MB03-0000
Compatible with the MD03 DIN rail, this end bracket is an accessory or replacement part.




Eurotherm MD03-0000 TS35 x 7.5 DIN Rail, 6.56' MD03-0000
Compatible with WV series signal conditioners, isolators, alarms, and power supplies, this TS35 x 7.5 DIN Rail is an accessory or replacement part. In addition, this rail features a length of 6.56' (2 m).




Poser une question sur le Eurotherm WV118-2000.V1 DC Powered RTD Input Limit Alarm, -328 to 1112°F, 2 SPDT relays

Eurotherm WV118-2000.V1 offre

Accurate and stable, this DC-powered RTD input limit alarm features two standard non-latching SPDT relays. In addition, this alarm features high or low trips and failsafe or non-failsafe operation.

Caractéristiques

  • Programmable high or low, failsafe or non-failsafe
  • Improved accuracy
  • Adjustable deadband
  • Bussed power with plug-in power clips
  • Removable terminals for easy service
  • TouchCAL for best stability and accuracy
  • RoHS compliant
  • LED trip and input indicators
  • Supports two-wire and three-wire RTDs

Spécifications pour le Eurotherm WV118-2000.V1

Inputs Sensor types: Pt100 0.00385, Pt100 0.00392, Cu10
Sensor Connection Two-wire or three-wire
Ranges Pt100 RTDs: -32 to 1112°F (-200 to 600°C), Alpha: 0.00385
Cu10 RTDs: -328 to 500°F (-200 to 260°C)
RTD Excitation Pt100: 0.45 mA, maximum
Cu10: 5.0 mA, maximum
Lead Wire Resistance: 40% of the base sensor resistance maximum or 100 Ω (whichever is less)
Effect: Changing from 0 Ω lead resistance (each lead) to maximum allowed lead resistance: Error <1% of largest span PT and Cu ranges; -32 to 1112°F (-200 to 600°C) for Pt and -328 to 500°F (-200 to 260°C) for Cu
Pushbutton Adjustment Effective zero offset: >95%
(Inputs >10 mV): Effective span turn down: >95%
Local Range Selection By DIP switch
Response Time Dynamic deadband: Relay status will change when proper setpoint/process condition exists for 100 ms
Normal mode: <250 ms (analog filtering)
Setpoint Effectivity Setpoints are adjustable (by pushbutton) over 100% of the selected input span
Repeatability ±0.05% of FS, ±1°C (constant temp)
Relay Contacts 2 SPDT (2 form C) relays, 1 relay per setpoint
Current rating (general use) 120 V AC: 5 A; 240 V AC: 2 A; 28 V DC: 5 A
Material Gold flash over silver alloy
Electrical Life 105 operations at rated load
Stability ±100 ppm of full scale/°C (±0.01%/°C)
Common Mode Rejection 120 dB at DC, >90 dB at 60 Hz, or better
Isolation >1800 V DC or peak AC between input, output and power
ESD Susceptibility Capable of meeting IEC 801-2 level 3 (8 kV)
Humidity (non-condensing) Operating: 15 to 95% RH at 113°F (45°C)
Soak: 90% RH for 24 hours at 140°F (60°C)
Temperature Operating: 32 to 140°F (0 to 60°C)
Storage: -13 to 185°F (-25 to 85°C)
Host Module Interface IR link, same specs as phase 1 modules
Agency Approvals (EMC and Safety) UL recognized per standard UL508 (File No.E99775)
CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (Input <75 V DC, only)
RoHS compliant
Power 9 to 30 V DC, 1 W typical, 2 W maximum
Dimensions 4.39 x 3.54 x 0.69" (111.6 x 90 x 17.5 mm)
DIN rail case

Le Eurotherm WV118-2000.V1 comprend

  • Eurotherm WV118-2000.V1 DC Powered RTD Input Limit Alarm, -328 to 1112°F, 2 SPDT relays

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Eurotherm WV118-2000.V1 DC Powered RTD Input Limit Alarm, -328 to 1112°F, 2 SPDT relays.

Eurotherm H910-0024 DIN-Rail Mount Power Supply, 1000 mA at 24 V DC, 115 to 230 V AC H910-0024
Ideal for use with 24 V DC-powered products, this DIN-rail mount power supply supplies up to 1000 mA at 24 V DC. In addition, this power supply features an LED power indicator, input fuse protection, and output DC short circuit protection.




Eurotherm H915-0001-1 DIN-Rail Mount Power Supply, 2300 mA at 24 V DC, 85 to 265 V AC H915-0001-1
Ideal for use with 24 V DC-powered products, this DIN-rail mount power supply supplies up to 2300 mA at 24 V DC and has multiple wire terminal connections. In addition, this power supply features an LED power indicator, input fuse protection, and output DC short circuit protection.




Eurotherm MB03-0000 End Bracket for the MD03 MB03-0000
Compatible with the MD03 DIN rail, this end bracket is an accessory or replacement part.




Eurotherm MD03-0000 TS35 x 7.5 DIN Rail, 6.56' MD03-0000
Compatible with WV series signal conditioners, isolators, alarms, and power supplies, this TS35 x 7.5 DIN Rail is an accessory or replacement part. In addition, this rail features a length of 6.56' (2 m).




Poser une question sur le Eurotherm WV118-2000.V1 DC Powered RTD Input Limit Alarm, -328 to 1112°F, 2 SPDT relays

Plus de produits Eurotherm