Configurable as a single or dual setpoint alarm, this DC-powered RTD input limit alarm provides relay contact closures at a preset temperature level. In addition, this alarm features dual setpoints and two contact closures, and the input type and alarm functions are field configurable.
Configurable as a single or dual setpoint alarm, this DC-powered RTD input limit alarm provides relay contact closures at a preset temperature level. In addition, this alarm features dual setpoints and two contact closures, and the input type and alarm functions are field configurable.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Accurate and stable, this DC-powered RTD input limit alarm features two standard non-latching SPDT relays. In addition, this alarm features high or low trips and failsafe or non-failsafe operation.
Features
| Inputs | Sensor types: Pt100 0.00385, Pt100 0.00392, Cu10 |
| Sensor Connection | Two-wire or three-wire |
| Ranges | Pt100 RTDs: -32 to 1112°F (-200 to 600°C), Alpha: 0.00385 Cu10 RTDs: -328 to 500°F (-200 to 260°C) |
| RTD Excitation | Pt100: 0.45 mA, maximum Cu10: 5.0 mA, maximum |
| Lead Wire | Resistance: 40% of the base sensor resistance maximum or 100 Ω (whichever is less) Effect: Changing from 0 Ω lead resistance (each lead) to maximum allowed lead resistance: Error <1% of largest span PT and Cu ranges; -32 to 1112°F (-200 to 600°C) for Pt and -328 to 500°F (-200 to 260°C) for Cu |
| Pushbutton Adjustment | Effective zero offset: >95% (Inputs >10 mV): Effective span turn down: >95% |
| Local Range Selection | By DIP switch |
| Response Time | Dynamic deadband: Relay status will change when proper setpoint/process condition exists for 100 ms Normal mode: <250 ms (analog filtering) |
| Setpoint Effectivity | Setpoints are adjustable (by pushbutton) over 100% of the selected input span |
| Repeatability | ±0.05% of FS, ±1°C (constant temp) |
| Relay Contacts | 2 SPDT (2 form C) relays, 1 relay per setpoint |
| Current rating (general use) | 120 V AC: 5 A; 240 V AC: 2 A; 28 V DC: 5 A |
| Material | Gold flash over silver alloy |
| Electrical Life | 105 operations at rated load |
| Stability | ±100 ppm of full scale/°C (±0.01%/°C) |
| Common Mode Rejection | 120 dB at DC, >90 dB at 60 Hz, or better |
| Isolation | >1800 V DC or peak AC between input, output and power |
| ESD Susceptibility | Capable of meeting IEC 801-2 level 3 (8 kV) |
| Humidity (non-condensing) | Operating: 15 to 95% RH at 113°F (45°C) Soak: 90% RH for 24 hours at 140°F (60°C) |
| Temperature | Operating: 32 to 140°F (0 to 60°C) Storage: -13 to 185°F (-25 to 85°C) |
| Host Module Interface | IR link, same specs as phase 1 modules |
| Agency Approvals (EMC and Safety) | UL recognized per standard UL508 (File No.E99775) CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (Input <75 V DC, only) RoHS compliant |
| Power | 9 to 30 V DC, 1 W typical, 2 W maximum |
| Dimensions | 4.39 x 3.54 x 0.69" (111.6 x 90 x 17.5 mm) DIN rail case |
Click on a category to view a selection of compatible accessories with the Eurotherm WV118-2000.V1 DC Powered RTD Input Limit Alarm, -328 to 1112°F, 2 SPDT relays.
| Inputs | Sensor types: Pt100 0.00385, Pt100 0.00392, Cu10 |
| Sensor Connection | Two-wire or three-wire |
| Ranges | Pt100 RTDs: -32 to 1112°F (-200 to 600°C), Alpha: 0.00385 Cu10 RTDs: -328 to 500°F (-200 to 260°C) |
| RTD Excitation | Pt100: 0.45 mA, maximum Cu10: 5.0 mA, maximum |
| Lead Wire | Resistance: 40% of the base sensor resistance maximum or 100 Ω (whichever is less) Effect: Changing from 0 Ω lead resistance (each lead) to maximum allowed lead resistance: Error <1% of largest span PT and Cu ranges; -32 to 1112°F (-200 to 600°C) for Pt and -328 to 500°F (-200 to 260°C) for Cu |
| Pushbutton Adjustment | Effective zero offset: >95% (Inputs >10 mV): Effective span turn down: >95% |
| Local Range Selection | By DIP switch |
| Response Time | Dynamic deadband: Relay status will change when proper setpoint/process condition exists for 100 ms Normal mode: <250 ms (analog filtering) |
| Setpoint Effectivity | Setpoints are adjustable (by pushbutton) over 100% of the selected input span |
| Repeatability | ±0.05% of FS, ±1°C (constant temp) |
| Relay Contacts | 2 SPDT (2 form C) relays, 1 relay per setpoint |
| Current rating (general use) | 120 V AC: 5 A; 240 V AC: 2 A; 28 V DC: 5 A |
| Material | Gold flash over silver alloy |
| Electrical Life | 105 operations at rated load |
| Stability | ±100 ppm of full scale/°C (±0.01%/°C) |
| Common Mode Rejection | 120 dB at DC, >90 dB at 60 Hz, or better |
| Isolation | >1800 V DC or peak AC between input, output and power |
| ESD Susceptibility | Capable of meeting IEC 801-2 level 3 (8 kV) |
| Humidity (non-condensing) | Operating: 15 to 95% RH at 113°F (45°C) Soak: 90% RH for 24 hours at 140°F (60°C) |
| Temperature | Operating: 32 to 140°F (0 to 60°C) Storage: -13 to 185°F (-25 to 85°C) |
| Host Module Interface | IR link, same specs as phase 1 modules |
| Agency Approvals (EMC and Safety) | UL recognized per standard UL508 (File No.E99775) CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (Input <75 V DC, only) RoHS compliant |
| Power | 9 to 30 V DC, 1 W typical, 2 W maximum |
| Dimensions | 4.39 x 3.54 x 0.69" (111.6 x 90 x 17.5 mm) DIN rail case |
Click on a category to view a selection of compatible accessories with the Eurotherm WV118-2000.V1 DC Powered RTD Input Limit Alarm, -328 to 1112°F, 2 SPDT relays.