Amprobe AT-6030 Advanced Wire Tracer Kit with signal clamp

Modèle: AT-6030 | CUP: 095969842730

Amprobe AT-6030 Advanced Wire Tracer Kit with signal clamp

Modèle: AT-6030 | CUP: 095969842730

Easily and safely locate energized and de-energized wires, breakers, and fuses with this wire tracer kit. Comes equipped with a transmitter and receiver to easily detect signals in wires or cables behind walls, ceilings, and floors, along with the CT-400 Signal Clamp.

Easily and safely locate energized and de-energized wires, breakers, and fuses with this wire tracer kit. Comes equipped with a transmitter and receiver to easily detect signals in wires or cables behind walls, ceilings, and floors, along with the CT-400 Signal Clamp.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :

Fluke 2052 Ensemble de traceur de câbles, CAT IV 600 V, 600 V CA/CC-

Fluke 2052 Ensemble de traceur de câbles, CAT IV 600 V, 600 V CA/CC

Modèle: 2052

Conçue pour assurer votre sécurité, cet ensemble de traceur de câbles avancé permet de dépanner avec précision et en toute sécurité les fils sous tension/hors tension dans les environnements résidentiels, commerciaux et industriels jusqu'à CAT IV 600 V. De plus, l'ensemble est livré avec un récepteur, un transmetteur, une pince de courant CA, un ensemble de fil d'essai et une mallette de transport.


Amprobe AT-6030 Offers

Locate and trace Energized and De-energized wires, automatically identify breakers

An easier and safer way to locate energized and de-energized wires, breakers and fuses. When the transmitter is connected to the circuit, the receiver easily detects the signal in the wires or cables behind walls, ceilings and floors. The transmitter works on energized and de-energized circuits up to 600 V AC/DC in Category I through Category III electrical environments, allowing for work directly on an energized circuit without the need to take equipment offline. The transmitter also features high signal mode for general tracing and a loop mode designed specifically for locating shorts, as well as two optimal tracing frequencies that are automatically activated based on the detected voltage.

Features

  • Traces wires in walls, ceilings, floors and corners
  • Locates breakers and fuses
  • Pinpoints shorts and opens
  • Large LCD Receiver screen with two digit readout, bar graph and sound to easily determine wire location
  • Two automatically selected frequency modes for reliable tracing on energized and de-energized circuits
  • Included CT-400 signal clamp improves accuracy and performance when there is no access to bare conductors

Receiver Features

  • Tip sensor - to trace wires in tight spaces
  • Large black and white LCD screen
  • Energized/De-energized indicator
  • Signal strength bar graph
  • Sensitivity adjustment
  • Quick Scan mode allows for quick wire detection at a longer distance
  • Precision mode precisely pinpoints wires or faults located behind walls, floors, or ceilings
  • Breaker Identification mode facilitates quick and easy breaker locating
  • Non-Contact Voltage Detection mode utilizes passive tracing without the Transmitter to verify if a wire is energized

Transmitter Features

  • Compatible with standard test leads
  • Voltage warning indicator
  • Simple one button operation
  • High Signal mode for normal circuits
  • Low Signal mode for precision tracing in difficult areas
  • Loop mode for closed loop de-energized circuits

Applications

  • Trace energized and de-energized wires
  • Identify breakers and fuses
  • Connect to GFCI protected circuits
  • Find breaks and opens
  • Find shorts
  • Trace wires in metal conduit
  • Trace non-metallic pipes and conduit
  • Trace shielded wires
  • Trace underground wires
  • Trace low voltage wires and data cables
  • Sort bundled wires
  • Map a circuit with test leads
  • Trace breakers on system with light dimmers

Amprobe AT-6030 Specifications

Receiver
Measurement Category CAT III 600 V
Operating Voltage 0 to 600 V AC/DC
Operating Frequency Energized: 6.25 kHz, De-Energized: 32.768 kHz
Signal Indications Numeric, bar graph display and audible beep
Response Time Tip sensor (Energized/De-energized): 500 ms
Battery voltage monitoring: 5 sec
Range Detection (Open Air) Tip sensor (Energized)
Max distance via air: up to 20' (6.1 m)
Pinpointing: approx. 1.97" (5 cm)
Tip sensor (De-energized)
Max distance via air: up to 14.7' (4.5 m)
Pinpointing: approx. 1.97" (5 cm)
Transmitter
Measurement Category CAT III 600 V
Operating Voltage 0 to 600 V AC/DC
Operating Frequency Energized: 6.25 kHz, De-Energized: 32.768 kHz
Hazardous Voltage Detection >30 V AC/DC
Signal Indications LEDs
Response Time Line voltage monitoring: 1 sec
Battery voltage monitoring: 5 sec
Current Output of Signal (Typical) Energized circuit: HI mode: 60 mA RMS
De-energized circuit: HI mode: 130 mA RMS
Loop mode: 160 mA RMS
Signal Voltage Output (Nominal) De-energized circuit: HIGH: 33 V RMS, 140 Vp-p
Signal Clamp
Measurement Category CAT IV 600 V, CAT III 1000 V
Operating Voltage 0 to 1000 V AC
Operating Frequency Wire tracing: 32.768 kHz
AC current measurement: 45 to 400 Hz
Response Time Instantaneous
Current Output of Signal (Typical) 1 mA/A for AC current measurement with multimeter
Signal Voltage Output (Nominal) De-energized circuit: 2.4 V RMS, 24 Vp-p
Cliquer ici pour toutes les spécifications du Amprobe AT-6030

What's included with the Amprobe AT-6030

  • Receiver
  • Transmitter
  • CT-400 Signal Clamp
  • Test Lead and Accessory Kit:
    • 2 x 3.3' (1 m) Test Leads (Red, Black)
    • 22.9' (7 m) Test Lead (Green)
    • 2 x Alligator Clips (Red, Black)
    • 2 x Outlet Blade Adapter (Red, Black)
    • 2 x Outlet Round Adapter (Red, Black)
  • Hard Carrying Case
  • 12 x Rechargeable Batteries
  • 3 x Battery Chargers
  • User Manual

Poser une question sur le Amprobe AT-6030 Advanced Wire Tracer Kit with signal clamp

Amprobe AT-6030 Offers

Locate and trace Energized and De-energized wires, automatically identify breakers

An easier and safer way to locate energized and de-energized wires, breakers and fuses. When the transmitter is connected to the circuit, the receiver easily detects the signal in the wires or cables behind walls, ceilings and floors. The transmitter works on energized and de-energized circuits up to 600 V AC/DC in Category I through Category III electrical environments, allowing for work directly on an energized circuit without the need to take equipment offline. The transmitter also features high signal mode for general tracing and a loop mode designed specifically for locating shorts, as well as two optimal tracing frequencies that are automatically activated based on the detected voltage.

Features

  • Traces wires in walls, ceilings, floors and corners
  • Locates breakers and fuses
  • Pinpoints shorts and opens
  • Large LCD Receiver screen with two digit readout, bar graph and sound to easily determine wire location
  • Two automatically selected frequency modes for reliable tracing on energized and de-energized circuits
  • Included CT-400 signal clamp improves accuracy and performance when there is no access to bare conductors

Receiver Features

  • Tip sensor - to trace wires in tight spaces
  • Large black and white LCD screen
  • Energized/De-energized indicator
  • Signal strength bar graph
  • Sensitivity adjustment
  • Quick Scan mode allows for quick wire detection at a longer distance
  • Precision mode precisely pinpoints wires or faults located behind walls, floors, or ceilings
  • Breaker Identification mode facilitates quick and easy breaker locating
  • Non-Contact Voltage Detection mode utilizes passive tracing without the Transmitter to verify if a wire is energized

Transmitter Features

  • Compatible with standard test leads
  • Voltage warning indicator
  • Simple one button operation
  • High Signal mode for normal circuits
  • Low Signal mode for precision tracing in difficult areas
  • Loop mode for closed loop de-energized circuits

Applications

  • Trace energized and de-energized wires
  • Identify breakers and fuses
  • Connect to GFCI protected circuits
  • Find breaks and opens
  • Find shorts
  • Trace wires in metal conduit
  • Trace non-metallic pipes and conduit
  • Trace shielded wires
  • Trace underground wires
  • Trace low voltage wires and data cables
  • Sort bundled wires
  • Map a circuit with test leads
  • Trace breakers on system with light dimmers

Amprobe AT-6030 Specifications

Receiver
Measurement Category CAT III 600 V
Operating Voltage 0 to 600 V AC/DC
Operating Frequency Energized: 6.25 kHz, De-Energized: 32.768 kHz
Signal Indications Numeric, bar graph display and audible beep
Response Time Tip sensor (Energized/De-energized): 500 ms
Battery voltage monitoring: 5 sec
Range Detection (Open Air) Tip sensor (Energized)
Max distance via air: up to 20' (6.1 m)
Pinpointing: approx. 1.97" (5 cm)
Tip sensor (De-energized)
Max distance via air: up to 14.7' (4.5 m)
Pinpointing: approx. 1.97" (5 cm)
Transmitter
Measurement Category CAT III 600 V
Operating Voltage 0 to 600 V AC/DC
Operating Frequency Energized: 6.25 kHz, De-Energized: 32.768 kHz
Hazardous Voltage Detection >30 V AC/DC
Signal Indications LEDs
Response Time Line voltage monitoring: 1 sec
Battery voltage monitoring: 5 sec
Current Output of Signal (Typical) Energized circuit: HI mode: 60 mA RMS
De-energized circuit: HI mode: 130 mA RMS
Loop mode: 160 mA RMS
Signal Voltage Output (Nominal) De-energized circuit: HIGH: 33 V RMS, 140 Vp-p
Signal Clamp
Measurement Category CAT IV 600 V, CAT III 1000 V
Operating Voltage 0 to 1000 V AC
Operating Frequency Wire tracing: 32.768 kHz
AC current measurement: 45 to 400 Hz
Response Time Instantaneous
Current Output of Signal (Typical) 1 mA/A for AC current measurement with multimeter
Signal Voltage Output (Nominal) De-energized circuit: 2.4 V RMS, 24 Vp-p
Cliquer ici pour toutes les spécifications du Amprobe AT-6030

What's included with the Amprobe AT-6030

  • Receiver
  • Transmitter
  • CT-400 Signal Clamp
  • Test Lead and Accessory Kit:
    • 2 x 3.3' (1 m) Test Leads (Red, Black)
    • 22.9' (7 m) Test Lead (Green)
    • 2 x Alligator Clips (Red, Black)
    • 2 x Outlet Blade Adapter (Red, Black)
    • 2 x Outlet Round Adapter (Red, Black)
  • Hard Carrying Case
  • 12 x Rechargeable Batteries
  • 3 x Battery Chargers
  • User Manual

Poser une question sur le Amprobe AT-6030 Advanced Wire Tracer Kit with signal clamp

Plus de produits Amprobe