Leak detection of refrigerants is of great importance to prevent environmental damage and to ensure the safe operation of refrigeration units, air conditioning systems and heat pumps. By quickly identifying and repairing leaks, we can minimise the release of climate-damaging substances and extend the service life of our air conditioners and heat pumps.
Leak detection of refrigerants is of great importance to prevent environmental damage and to ensure the safe operation of refrigeration units, air conditioning systems and heat pumps. By quickly identifying and repairing leaks, we can minimise the release of climate-damaging substances and extend the service life of our air conditioners and heat pumps.
The RL 200 refrigerant leak detector is very easy to use. Thanks to its digital display, you always have an overview of the measured values. The automatic zero value setting makes handling even easier, so that you can concentrate on the actual task: detecting leaks in the refrigerant system. With its sensitivity of 3g/a, the RL 200 enables reliable detection of even the smallest refrigerant leaks. Developed following the strict guidelines of the F-Gas Regulation and BS EN 14624:2012, the RL 200 meets the highest standards in terms of environmental protection and technical precision.
With the RL 200 Refrigerant Leak Detector you are well equipped to increase the efficiency of your maintenance processes and minimise potential environmental impacts.
Caractéristiques
Applications
Detectable Refrigerants | FCKW: R11, R12, R500, R503 HFCKW: R22, R123, R124, R502 HFC: R134a, R404a, R410a, R407C, R32 Others: R290, R600a, R1234YF Forming Gas (95% N2 + 5% H2) |
R134a Sensitivity | 3 g/a |
R143a Response Time | < 1 second |
Recovery Time | 12 seconds |
Sensor | Heated diode |
Sensor Zeroing | Automatic and manual |
Alarm Function | Visual and acoustic |
Warm-up Time | Approximately 30 seconds |
Ambient Conditions | 32 to 122°F (0 to 50°C), < 80% RH (non-condensing) |
Power Supply | 3 x AA alkaline cells |
Detectable Refrigerants | FCKW: R11, R12, R500, R503 HFCKW: R22, R123, R124, R502 HFC: R134a, R404a, R410a, R407C, R32 Others: R290, R600a, R1234YF Forming Gas (95% N2 + 5% H2) |
R134a Sensitivity | 3 g/a |
R143a Response Time | < 1 second |
Recovery Time | 12 seconds |
Sensor | Heated diode |
Sensor Zeroing | Automatic and manual |
Alarm Function | Visual and acoustic |
Warm-up Time | Approximately 30 seconds |
Ambient Conditions | 32 to 122°F (0 to 50°C), < 80% RH (non-condensing) |
Power Supply | 3 x AA alkaline cells |