Winters LIS389 Intrinsically Safe Transmitter, 0 to 230 psi

Modèle: LIS389 | CUP: 628311521078

Winters LIS389 Intrinsically Safe Transmitter, 0 to 230 psi

Modèle: LIS389 | CUP: 628311521078

Compact, this intrinsically safe transmitter is made of stainless steel and has a ceramic sensor, and features a range of 0 to 230 psi.

Compact, this intrinsically safe transmitter is made of stainless steel and has a ceramic sensor, and features a range of 0 to 230 psi.

Prix spécial $1386.36 CAD
Prix régulier $1754.88 CAD
Disponibilité 2 à 3 semaines
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre LIS389 Intrinsically Safe Transmitter

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre LIS389 Intrinsically Safe Transmitter

Winters LIS389 Offers

Approved for intrinsically-safe applications in Class 1/Div. 1 hazardous areas.

Features

  • Rugged stainless steel construction with ceramic sensor
  • Available ranges include in/Hg up to 8700 psi
  • Wide range of mechanical and electrical connections
  • 0.5% FSO accuracy
  • Approved for outdoor use
  • Customizable

Applications

  • Oil and gas
  • Hazardous areas where an intrinsically safe rating is required

Winters LIS389 Specifications

Range 0 to 230 psi
Over-Pressure 580 psi
Burst Pressure 725 psi
Output Signal Standard 2-wire: 4-20 mA / Vs = 8 to 32 V DC
I.S. protection: Vs = 14 to 28 V DC
Optional 3-wire: 0 to 20 mA / Vs = 14 to 30 V DC
0 to 10 V / Vs = 14 to 30 V DC
Accuracy ±0.5% FSO IEC 60770
Permissible Load Current 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ohm
Current 3-wire: Rmax = 500 Ohm
Voltage 3-wire: Rmin = 10 kOhm
Influence Effects Supply: 0.05% FSO / 10 V
Load: 0.05% FSO / kOhm
Response Time ≤10 ms
Thermal Error ≤±0.2% FSO / 10K
In compensated range: -13 to 185°F (-25 to 85°C)
Permissible Temperatures Medium: : -40 to 257°F (-40 to 125°C)
Electronics environment: -13 to 185°F (-25 to 85°C)
Storage: -40 to 212°F (-40 to 100°C)
Short-circuit Protection Permanent
Reverse Polarity Protection No damage. No function
Electromagnetic Protection Emission and immunity according to EN 61326
I.S. Protection Class 1, Div. 1, Groups A, B, C and D
Stability Vibration: 10 g RMS (25 to 2000 Hz)
Shock: 500 g / 1 ms
Pollution Degree 4, electrical equipment for outdoor use
Connecting Cables Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m
Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m
Pressure Port/Housing 316L SS
Wetted Parts Seals: PPN <1450 psi: FKM70. Others available
PN >1450 psi: FKM90. Others available
Diaphragm: Ceramic AI&sub2;O&sub3; 96%
Current Consumption Current: 25 mA maximum
Voltage: 7 mA maximum
Operating Life >100 x 106 cycles
Weight 0.3 lbs (140 g)
Cliquer ici pour toutes les spécifications du Winters LIS389

What's included with the Winters LIS389

  • Intrinsically Safe Transmitter
  • 5-Year Warranty

Poser une question sur le Winters LIS389 Intrinsically Safe Transmitter, 0 to 230 psi

Winters LIS389 Offers

Approved for intrinsically-safe applications in Class 1/Div. 1 hazardous areas.

Features

  • Rugged stainless steel construction with ceramic sensor
  • Available ranges include in/Hg up to 8700 psi
  • Wide range of mechanical and electrical connections
  • 0.5% FSO accuracy
  • Approved for outdoor use
  • Customizable

Applications

  • Oil and gas
  • Hazardous areas where an intrinsically safe rating is required

Winters LIS389 Specifications

Range 0 to 230 psi
Over-Pressure 580 psi
Burst Pressure 725 psi
Output Signal Standard 2-wire: 4-20 mA / Vs = 8 to 32 V DC
I.S. protection: Vs = 14 to 28 V DC
Optional 3-wire: 0 to 20 mA / Vs = 14 to 30 V DC
0 to 10 V / Vs = 14 to 30 V DC
Accuracy ±0.5% FSO IEC 60770
Permissible Load Current 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ohm
Current 3-wire: Rmax = 500 Ohm
Voltage 3-wire: Rmin = 10 kOhm
Influence Effects Supply: 0.05% FSO / 10 V
Load: 0.05% FSO / kOhm
Response Time ≤10 ms
Thermal Error ≤±0.2% FSO / 10K
In compensated range: -13 to 185°F (-25 to 85°C)
Permissible Temperatures Medium: : -40 to 257°F (-40 to 125°C)
Electronics environment: -13 to 185°F (-25 to 85°C)
Storage: -40 to 212°F (-40 to 100°C)
Short-circuit Protection Permanent
Reverse Polarity Protection No damage. No function
Electromagnetic Protection Emission and immunity according to EN 61326
I.S. Protection Class 1, Div. 1, Groups A, B, C and D
Stability Vibration: 10 g RMS (25 to 2000 Hz)
Shock: 500 g / 1 ms
Pollution Degree 4, electrical equipment for outdoor use
Connecting Cables Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m
Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m
Pressure Port/Housing 316L SS
Wetted Parts Seals: PPN <1450 psi: FKM70. Others available
PN >1450 psi: FKM90. Others available
Diaphragm: Ceramic AI&sub2;O&sub3; 96%
Current Consumption Current: 25 mA maximum
Voltage: 7 mA maximum
Operating Life >100 x 106 cycles
Weight 0.3 lbs (140 g)
Cliquer ici pour toutes les spécifications du Winters LIS389

What's included with the Winters LIS389

  • Intrinsically Safe Transmitter
  • 5-Year Warranty

Poser une question sur le Winters LIS389 Intrinsically Safe Transmitter, 0 to 230 psi

Plus de produits Winters