Watlow DIN-A-MITE C SCR Power Controller with three independent zones and 24 V DC cooling fan, 277 to 600 V AC, 200 to 240 V AC input

Modèle: DC93-60K3-0000

Watlow DIN-A-MITE C SCR Power Controller with three independent zones and 24 V DC cooling fan, 277 to 600 V AC, 200 to 240 V AC input

Modèle: DC93-60K3-0000

Compact and powerful, this 24 V DC fan-cooled controller provides an economical and versatile solid state option for controlling electric heat. In addition, it is 200KA SCCR with proper fusing to minimize damage in the event of a short circuit and has three independent zones, 277 to 600 V AC line/load voltage, and 200 to 240 V AC control input.

Compact and powerful, this 24 V DC fan-cooled controller provides an economical and versatile solid state option for controlling electric heat. In addition, it is 200KA SCCR with proper fusing to minimize damage in the event of a short circuit and has three independent zones, 277 to 600 V AC line/load voltage, and 200 to 240 V AC control input.

Votre prix $1013.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Watlow DC93-60K3-0000 Offers

Features

  • 200KA SCCR with proper fusing minimizes damage in the event of a short circuit
  • DIN-rail and panel mounting provides versatility and quick, low-cost installation
  • Compact size reduces panel space and cost
  • Touch-safe terminals increases safety for installer and user
  • Mercury free assures environmental safety
  • Faster switching with solid state saves energy and extends heater life
  • UL® 508 listed, C-UL®, RoHS 2 and CE with filter meets applications requiring agency approval, and reduces end product documentation cost
  • System solution component provides single source thermal loop
  • Back-to-back SCR design ensures a rugged design

Applications

  • Controlling electric heat
  • Current switching

Watlow DC93-60K3-0000 Specifications

Operator Interface Control input and indication light
Alarm output and indication light
Current limit indication LED
Phase Three independent zones
Amperage Rating Maximum surge current for 16.6 ms, 1350 A peak
Maximum I2t for fusing is 9100 A2s
Latching current: 500 mA maximum
Holding current: 200 mA maximum
Fan current: 0.14 A
Off-state leakage 1 mA at 77°F (25°C) maximum
Power dissipation = 1.2 W/A per leg switched
200KA SCCR, Type 1 and 2 approved with the recommended fusing
Line Voltage 277 to 600 V AC: 85 V AC minimum to 660 V AC maximum
Control Mode, Zero-Cross V AC input, contactor output
Control Input 240 V AC +10/-25% at 25 mA maximum per controlled leg
Terminals Control input:
Compression: Will accept 24 to 16 AWG (0.2 to 1.5 mm2) wire
Torque to 4.4 inlb (0.5 Nm) maximum with a ⅛" (3.5 mm) blade screwdriver

Line and load:
Compression: Will accept 14 to 3 AWG (2.5 to 25 mm2) wire
Torque to 24 inlb (2.7 Nm) maximum with a ¼" (6.4 mm) blade screwdriver, or a type 1A, #2 Pozi driver
Operating Environment 0 to 90% RH (relative humidity), non-condensing
Storage temperature: -40 to 185°F (-40 to 85°C)
Operating temperature: -29 to 176°F (-34 to 80°C)
Insulation tested to 9842.52' (3000 m)
Mounting DIN-rail: DIN EN 50022, 1.4 x 0.3" (35 x 7.5 mm)
Back-panel: Four mounting holes No. 6 to No. 8 (M3 to M4) fastener
Dimensions 5.45 x 3.25 x 5.74" (138 x 83 x 146 mm)
Cliquer ici pour toutes les spécifications du Watlow DC93-60K3-0000

What's included with the Watlow DC93-60K3-0000

  • Power Controller
  • Three-Year Warranty

Poser une question sur le Watlow DIN-A-MITE C SCR Power Controller with three independent zones and 24 V DC cooling fan, 277 to 600 V AC, 200 to 240 V AC input

Watlow DC93-60K3-0000 Offers

Features

  • 200KA SCCR with proper fusing minimizes damage in the event of a short circuit
  • DIN-rail and panel mounting provides versatility and quick, low-cost installation
  • Compact size reduces panel space and cost
  • Touch-safe terminals increases safety for installer and user
  • Mercury free assures environmental safety
  • Faster switching with solid state saves energy and extends heater life
  • UL® 508 listed, C-UL®, RoHS 2 and CE with filter meets applications requiring agency approval, and reduces end product documentation cost
  • System solution component provides single source thermal loop
  • Back-to-back SCR design ensures a rugged design

Applications

  • Controlling electric heat
  • Current switching

Watlow DC93-60K3-0000 Specifications

Operator Interface Control input and indication light
Alarm output and indication light
Current limit indication LED
Phase Three independent zones
Amperage Rating Maximum surge current for 16.6 ms, 1350 A peak
Maximum I2t for fusing is 9100 A2s
Latching current: 500 mA maximum
Holding current: 200 mA maximum
Fan current: 0.14 A
Off-state leakage 1 mA at 77°F (25°C) maximum
Power dissipation = 1.2 W/A per leg switched
200KA SCCR, Type 1 and 2 approved with the recommended fusing
Line Voltage 277 to 600 V AC: 85 V AC minimum to 660 V AC maximum
Control Mode, Zero-Cross V AC input, contactor output
Control Input 240 V AC +10/-25% at 25 mA maximum per controlled leg
Terminals Control input:
Compression: Will accept 24 to 16 AWG (0.2 to 1.5 mm2) wire
Torque to 4.4 inlb (0.5 Nm) maximum with a ⅛" (3.5 mm) blade screwdriver

Line and load:
Compression: Will accept 14 to 3 AWG (2.5 to 25 mm2) wire
Torque to 24 inlb (2.7 Nm) maximum with a ¼" (6.4 mm) blade screwdriver, or a type 1A, #2 Pozi driver
Operating Environment 0 to 90% RH (relative humidity), non-condensing
Storage temperature: -40 to 185°F (-40 to 85°C)
Operating temperature: -29 to 176°F (-34 to 80°C)
Insulation tested to 9842.52' (3000 m)
Mounting DIN-rail: DIN EN 50022, 1.4 x 0.3" (35 x 7.5 mm)
Back-panel: Four mounting holes No. 6 to No. 8 (M3 to M4) fastener
Dimensions 5.45 x 3.25 x 5.74" (138 x 83 x 146 mm)
Cliquer ici pour toutes les spécifications du Watlow DC93-60K3-0000

What's included with the Watlow DC93-60K3-0000

  • Power Controller
  • Three-Year Warranty

Poser une question sur le Watlow DIN-A-MITE C SCR Power Controller with three independent zones and 24 V DC cooling fan, 277 to 600 V AC, 200 to 240 V AC input