Veris U006-0001 Leak Panel/Remote Annunciator, 1 zone

Modèle: U006-0001

Veris U006-0001 Leak Panel/Remote Annunciator, 1 zone

Modèle: U006-0001

The leak detection control panel continuously monitors up to 1,000' (305 m) of SC water detection cable per zone.

The leak detection control panel continuously monitors up to 1,000' (305 m) of SC water detection cable per zone.

Prix spécial $1555.15 CAD
Prix régulier $3247.09 CAD
Disponibilité 2 à 3 semaines
Quantité

Veris U006-0001 offre

The leak detection control panel continuously monitors up to 1,000' (305 m) of SC water detection cable per zone.

Caractéristiques

  • Monitor up to 1,000' (300 m) of water leak detection cable per zone for application flexibility
  • 2 LED indicators per zone; leak and cable fault
  • Sensitivity settings for each zone help eliminate false alarms and ensure maximum detection accuracy

Applications

  • Monitoring Data Centers, Computer Room Under-Floor Areas, Mechanical Rooms and Electrical Control Centers
  • Protecting Records Storage Rooms
  • Monitoring Plumbing in Facilities
  • Monitoring Chilled Beams

Spécifications pour le Veris U006-0001

Input Power 24 VAC/DC (±10%) @ 300 mA max
Water Leak Detection Cable Requires 15' (4.5 m) leader cable kit (LC-Kit) per zone
Maximum Cable Length 1,000' (305 m)
Detection Response Time LD300: configurable for 10 seconds or 2 minutes, ±10%
Relay Output 2 form C relays (leak and fault); 1 A at 24 VDC, 0.5 A resistive at 120 VAC
Alarm Notification Audible alarm: 85 dBA at 2' (0.6 m)
Push Buttons 1 for reset, quiet and test
Temperature 32 to 122°F (0 to 50°C)
Humidity 5 to 95% RH, non-condensing
Altitude 15,000' (4,572 m) max
Storage Environment -4 to 158°F (-20 to 70°C)
Weight 27 oz (766 g)
Certifications CE, ETL listed; conforms to UL 61010-1, RoHS Compliant

Le Veris U006-0001 comprend

  • Veris U006-0001 Leak Panel/Remote Annunciator, 1 zone

Poser une question sur le Veris U006-0001 Leak Panel/Remote Annunciator, 1 zone

Veris U006-0001 offre

The leak detection control panel continuously monitors up to 1,000' (305 m) of SC water detection cable per zone.

Caractéristiques

  • Monitor up to 1,000' (300 m) of water leak detection cable per zone for application flexibility
  • 2 LED indicators per zone; leak and cable fault
  • Sensitivity settings for each zone help eliminate false alarms and ensure maximum detection accuracy

Applications

  • Monitoring Data Centers, Computer Room Under-Floor Areas, Mechanical Rooms and Electrical Control Centers
  • Protecting Records Storage Rooms
  • Monitoring Plumbing in Facilities
  • Monitoring Chilled Beams

Spécifications pour le Veris U006-0001

Input Power 24 VAC/DC (±10%) @ 300 mA max
Water Leak Detection Cable Requires 15' (4.5 m) leader cable kit (LC-Kit) per zone
Maximum Cable Length 1,000' (305 m)
Detection Response Time LD300: configurable for 10 seconds or 2 minutes, ±10%
Relay Output 2 form C relays (leak and fault); 1 A at 24 VDC, 0.5 A resistive at 120 VAC
Alarm Notification Audible alarm: 85 dBA at 2' (0.6 m)
Push Buttons 1 for reset, quiet and test
Temperature 32 to 122°F (0 to 50°C)
Humidity 5 to 95% RH, non-condensing
Altitude 15,000' (4,572 m) max
Storage Environment -4 to 158°F (-20 to 70°C)
Weight 27 oz (766 g)
Certifications CE, ETL listed; conforms to UL 61010-1, RoHS Compliant