Veris H922 Current Transducer Split-Core 0-120A 0-5VDC

Modèle: H922

Veris H922 Current Transducer Split-Core 0-120A 0-5VDC

Modèle: H922

The current transducer split-core provides accurate load trending information with a proportional 0 to 5V DC output signal. It features slide-switches, which provide an easy field selection of monitored amperage range without jumpers.

The current transducer split-core provides accurate load trending information with a proportional 0 to 5V DC output signal. It features slide-switches, which provide an easy field selection of monitored amperage range without jumpers.

Prix spécial $119.70 CAD
Prix régulier $248.86 CAD
Disponibilité 2 à 3 semaines
Quantité

Veris H922 Offers

Features

  • No external power required for sensor...eliminate power supplies
  • Self-gripping split-core for fast retrofit installation, no need to remove conductor
  • No jumpers on unit, reduces installation error
  • Available with three field-selectable ranges per unit, fewer versions to choose from, stock, and install
  • Bracket can be installed in three different configurations, added flexibility
  • 100% solid state, no moving parts to fail
  • 5-year limited warranty

Applications

  • Load trending
  • Motor control
  • Fan/Pump Status

Veris H922 Specifications

Sensor Power Induced from monitored conductor
Insulation Class 600 Vac RMS (UL), 300 Vac RMS (CE1)
Range Frequency: 50/60 Hz nominal
Temperature: 10 to 90% RH non-condensing
Accuracy ±2% F.S. from 10% to 100% (range)
Response Time 2 seconds
Terminal Block Wire dimensions: 24 to 14 AWG (0.2 to 2.1 mm2)
Torque: 3.5 to 4.4 in-lbs. (0.4 to 0.5 N-m)
Cliquer ici pour toutes les spécifications du Veris H922

Le Veris H922 comprend

  • Veris H922 Current Transducer Split-Core 0-120A 0-5VDC

Poser une question sur le Veris H922 Current Transducer Split-Core 0-120A 0-5VDC

Veris H922 Offers

Features

  • No external power required for sensor...eliminate power supplies
  • Self-gripping split-core for fast retrofit installation, no need to remove conductor
  • No jumpers on unit, reduces installation error
  • Available with three field-selectable ranges per unit, fewer versions to choose from, stock, and install
  • Bracket can be installed in three different configurations, added flexibility
  • 100% solid state, no moving parts to fail
  • 5-year limited warranty

Applications

  • Load trending
  • Motor control
  • Fan/Pump Status

Veris H922 Specifications

Sensor Power Induced from monitored conductor
Insulation Class 600 Vac RMS (UL), 300 Vac RMS (CE1)
Range Frequency: 50/60 Hz nominal
Temperature: 10 to 90% RH non-condensing
Accuracy ±2% F.S. from 10% to 100% (range)
Response Time 2 seconds
Terminal Block Wire dimensions: 24 to 14 AWG (0.2 to 2.1 mm2)
Torque: 3.5 to 4.4 in-lbs. (0.4 to 0.5 N-m)
Cliquer ici pour toutes les spécifications du Veris H922

Le Veris H922 comprend

  • Veris H922 Current Transducer Split-Core 0-120A 0-5VDC

Poser une question sur le Veris H922 Current Transducer Split-Core 0-120A 0-5VDC