Veris H900 Current Monitoring Split-Core Current Switch, fixed trip point, 1.5 to 200 A

Modèle: H900 | No. de commande: H900/A

Veris H900 Current Monitoring Split-Core Current Switch, fixed trip point, 1.5 to 200 A

Modèle: H900 | No. de commande: H900/A

The current switch with fixed trip point is ideal for direct-drive units, unit vents, fan coil units, exhaust fans and other fixed loads.

The current switch with fixed trip point is ideal for direct-drive units, unit vents, fan coil units, exhaust fans and other fixed loads.

Prix spécial $106.40 CAD
Prix régulier $220.35 CAD
Disponibilité 5 à 6 semaines
Quantité

Veris H900 Offers

The current switch with fixed trip point is ideal for direct-drive units, unit vents, fan coil units, exhaust fans and other fixed loads.

Features

  • More reliable for status than relays across auxiliary contacts
  • Bracket can be installed in 3 different configurations
  • Split-core for fast retrofit installation
  • 100% solid-state, no moving parts to fail
  • Polarity insensitive output
  • 5-year limited warranty

Applications

  • Monitoring On/Off Status of Electrical Loads
  • Monitoring Direct-Drive Units, Exhaust Fans and Other Fixed Loads
  • Verifying Lighting Run Times

Veris H900 Specifications

Sensor Power N.O models: induced from monitored current; H800NC: 5 to 30 VDC, permanently connected
Insulation Class 600 VAC RMS (UL), 300 VAC RMS (CE*)
Frequency Range 50/60 Hz, on/off status for Variable Frequency Drive (VFD) outputs at 12 to 115 Hz (a)
Temperature Range H800NC, H300, H900: 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH non-condensing
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 mm²)
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
Warranty 5 years limited
Agency Approvals UL 508 open device listing; CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation
Cliquer ici pour toutes les spécifications du Veris H900

Le Veris H900 comprend

  • Veris H900 Current Monitoring Split-Core Current Switch, fixed trip point, 1.5 to 200 A

Poser une question sur le Veris H900 Current Monitoring Split-Core Current Switch, fixed trip point, 1.5 to 200 A

Veris H900 Offers

The current switch with fixed trip point is ideal for direct-drive units, unit vents, fan coil units, exhaust fans and other fixed loads.

Features

  • More reliable for status than relays across auxiliary contacts
  • Bracket can be installed in 3 different configurations
  • Split-core for fast retrofit installation
  • 100% solid-state, no moving parts to fail
  • Polarity insensitive output
  • 5-year limited warranty

Applications

  • Monitoring On/Off Status of Electrical Loads
  • Monitoring Direct-Drive Units, Exhaust Fans and Other Fixed Loads
  • Verifying Lighting Run Times

Veris H900 Specifications

Sensor Power N.O models: induced from monitored current; H800NC: 5 to 30 VDC, permanently connected
Insulation Class 600 VAC RMS (UL), 300 VAC RMS (CE*)
Frequency Range 50/60 Hz, on/off status for Variable Frequency Drive (VFD) outputs at 12 to 115 Hz (a)
Temperature Range H800NC, H300, H900: 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH non-condensing
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 mm²)
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
Warranty 5 years limited
Agency Approvals UL 508 open device listing; CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation