This line of power & energy meters is designed for revenue grade commercial metering applications. Each meter includes CTs calibrated to the meter for greater system-wide accuracy. Available for single to three phase applications from 120 to 480V.

This line of power & energy meters is designed for revenue grade commercial metering applications. Each meter includes CTs calibrated to the meter for greater system-wide accuracy. Available for single to three phase applications from 120 to 480V.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:

Visitez notre catégorie Compteurs énergétiques commerciaux/industriels pour trouver des produits similaires.

Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:


Veris H8150/8163 offre

Note: This product is not BACNET native and requires an accessory to be BACNET Capable. Purchase the H8186-CB to enable this feature. Learn more here.

The H81xx Series Energy Meters are easy to install and provide exceptional system accuracy, making them ideal for all submetering applications.

Each meter is factory-matched with one to three split-core CTs. The meter/CT pairs are system-calibrated to provide excellent total system accuracies of 1% from 2% to 100% of the amperage rating of the CTs (e.g., 2-100 amps with 100 amp CTs). Matching serial numbers assure that the meter and CT were calibrated together (matching does not apply if using 100A CTs).

The H81xx is easy to install. The split-core CTs eliminate the need to remove electrical conductors, reducing installation time. The meter is also capable of detecting and correcting phase reversal, eliminating the need for concern about CT load orientation. The convenient color coding of the CTs and voltage leads make correct connection simple.

Caractéristiques

  • Revenue Grade measurements
  • High resolution backlit LCD display provides clear readings at a distance... reduces the risk of misinterpretation of the data. Back-lighting can be disabled if desired
  • H8163 provides a pulse output from 1/10 to 1 pulse per kWh for easy connection to existing control or data acquisition systems
  • Provides a phase-loss alarm... protects equipment (H8163)
  • With the optional communications board (H81xx-CB), the H81xx can easily be added to a Modbus, BACnet or N2 control system network to report multiple variables including kW, kWh, kVAR, PF, Amps and Volts, providing crucial power information at a reduced installation cost
  • Split-core CTs eliminate the need to remove electrical conductors...reduces installation time
  • Energy meters automatically detect and correct phase reversal, eliminating the need to be concerned with CT load orientation
  • CTs and voltage leads are color coded making it easy to determine correct connection

Applications

  • Commercial Tenant Submetering
  • Performance Contracting
  • Allocating Costs
  • Real-Time Power Monitoring Via Local Display or Through Control/Data Acquisition Systems

Spécifications pour le Veris H8150/8163

Voltage Tolerance 90 to 132VAC Line-to-Neutral
Operating Temperature Range 0 to 50°C (32 to 122°F) (<95%RH, Non-Condensing)
Electrical Services 120/240 VAC with Neutral, 208Y/120 VAC Line to Neutral
Power Consumption 50VA
Insulation Class 600VAC
Internal Isolation 2500VAC
LCD Display 1.2 x 3.8" (31 x 97mm) Viewing Area, 160 Segments, Back-Lit with Green LEDs
Sample Rate 1280Hz
Storage Temperature Range -40 to 70°C (-40 to 158°F)
Systems Accuracy ±1% of reading from 2% to 100% of the rated current of the CTs, accomplished by matching the CTs with a meter and calibrating them as a system
Frequency 50/60Hz
Protection Class NEMA 1

Le Veris H8150/8163 comprend

  • Revenue Grade Power Meter
  • Calibrated CTs

Poser une question sur le Veris H8150/8163 Series Revenue Grade Power Meters

Veris H8150/8163 offre

Note: This product is not BACNET native and requires an accessory to be BACNET Capable. Purchase the H8186-CB to enable this feature. Learn more here.

The H81xx Series Energy Meters are easy to install and provide exceptional system accuracy, making them ideal for all submetering applications.

Each meter is factory-matched with one to three split-core CTs. The meter/CT pairs are system-calibrated to provide excellent total system accuracies of 1% from 2% to 100% of the amperage rating of the CTs (e.g., 2-100 amps with 100 amp CTs). Matching serial numbers assure that the meter and CT were calibrated together (matching does not apply if using 100A CTs).

The H81xx is easy to install. The split-core CTs eliminate the need to remove electrical conductors, reducing installation time. The meter is also capable of detecting and correcting phase reversal, eliminating the need for concern about CT load orientation. The convenient color coding of the CTs and voltage leads make correct connection simple.

Caractéristiques

  • Revenue Grade measurements
  • High resolution backlit LCD display provides clear readings at a distance... reduces the risk of misinterpretation of the data. Back-lighting can be disabled if desired
  • H8163 provides a pulse output from 1/10 to 1 pulse per kWh for easy connection to existing control or data acquisition systems
  • Provides a phase-loss alarm... protects equipment (H8163)
  • With the optional communications board (H81xx-CB), the H81xx can easily be added to a Modbus, BACnet or N2 control system network to report multiple variables including kW, kWh, kVAR, PF, Amps and Volts, providing crucial power information at a reduced installation cost
  • Split-core CTs eliminate the need to remove electrical conductors...reduces installation time
  • Energy meters automatically detect and correct phase reversal, eliminating the need to be concerned with CT load orientation
  • CTs and voltage leads are color coded making it easy to determine correct connection

Applications

  • Commercial Tenant Submetering
  • Performance Contracting
  • Allocating Costs
  • Real-Time Power Monitoring Via Local Display or Through Control/Data Acquisition Systems

Spécifications pour le Veris H8150/8163

Voltage Tolerance 90 to 132VAC Line-to-Neutral
Operating Temperature Range 0 to 50°C (32 to 122°F) (<95%RH, Non-Condensing)
Electrical Services 120/240 VAC with Neutral, 208Y/120 VAC Line to Neutral
Power Consumption 50VA
Insulation Class 600VAC
Internal Isolation 2500VAC
LCD Display 1.2 x 3.8" (31 x 97mm) Viewing Area, 160 Segments, Back-Lit with Green LEDs
Sample Rate 1280Hz
Storage Temperature Range -40 to 70°C (-40 to 158°F)
Systems Accuracy ±1% of reading from 2% to 100% of the rated current of the CTs, accomplished by matching the CTs with a meter and calibrating them as a system
Frequency 50/60Hz
Protection Class NEMA 1

Le Veris H8150/8163 comprend

  • Revenue Grade Power Meter
  • Calibrated CTs