Veris H6ECM05 Split-Core Current Switch, proof of rotation (flow) for ECM systems

Modèle: H6ECM05

Veris H6ECM05 Split-Core Current Switch, proof of rotation (flow) for ECM systems

Modèle: H6ECM05

The split-core current-sensitive switching device is optimized for most ECM motors and monitors the current in the conductor passing through it to the ECM.

The split-core current-sensitive switching device is optimized for most ECM motors and monitors the current in the conductor passing through it to the ECM.

Prix spécial $99.75 CAD
Prix régulier $208.03 CAD
Disponibilité 3 à 4 semaines
Quantité

Veris H6ECM05 Specifications

Sensor Power Induced from the monitored conductor
Amperage Range 0.5 A to 175 A continuous (monitored conductor)
Status Output Rating N.O. 1 A at 30 VAC/DC, not polarity sensitive
Setpoint 0.5 A (ECM optimized)
Frequency Range 60 Hz only
Accuracy ±10%
Temperature Range 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH non-condensing
Hysteresis 10% typical
Off State Resistance Open switch represents > 1 M Ohm
On State Resistance Closed switch represents < 200 m Ohm
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 sq. mm)
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
Agency Approvals UL508 open device listing
Insulation Class 600 VAC RMS
Installation Category Cat. III, pollution degree 2
Cliquer ici pour toutes les spécifications du Veris H6ECM05

Le Veris H6ECM05 comprend

  • Veris H6ECM05 Split-Core Current Switch, proof of rotation (flow) for ECM systems

Poser une question sur le Veris H6ECM05 Split-Core Current Switch, proof of rotation (flow) for ECM systems

Veris H6ECM05 Specifications

Sensor Power Induced from the monitored conductor
Amperage Range 0.5 A to 175 A continuous (monitored conductor)
Status Output Rating N.O. 1 A at 30 VAC/DC, not polarity sensitive
Setpoint 0.5 A (ECM optimized)
Frequency Range 60 Hz only
Accuracy ±10%
Temperature Range 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH non-condensing
Hysteresis 10% typical
Off State Resistance Open switch represents > 1 M Ohm
On State Resistance Closed switch represents < 200 m Ohm
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 sq. mm)
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
Agency Approvals UL508 open device listing
Insulation Class 600 VAC RMS
Installation Category Cat. III, pollution degree 2
Cliquer ici pour toutes les spécifications du Veris H6ECM05

Le Veris H6ECM05 comprend

  • Veris H6ECM05 Split-Core Current Switch, proof of rotation (flow) for ECM systems

Poser une question sur le Veris H6ECM05 Split-Core Current Switch, proof of rotation (flow) for ECM systems

Plus de produits Veris