Veris H6812-1200A-5AU Large Split Core Current Transformer, 1200 A: 5 A

Modèle: H6812-1200A-5AU

Veris H6812-1200A-5AU Large Split Core Current Transformer, 1200 A: 5 A

Modèle: H6812-1200A-5AU

The large split-core current transformer features 1200 A and a 5 A output.

The large split-core current transformer features 1200 A and a 5 A output.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :

Schneider Electric METSECTSP5A4120U PowerLogic™ Split-Core Current Transformer, large, 1200 A, 71 kA-

Schneider Electric METSECTSP5A4120U PowerLogic™ Split-Core Current Transformer, large, 1200 A, 71 kA

Modèle: METSECTSP5A4120U

A large split-core current transformer rated at 1200 A primary and 71 kA, featuring a 2.47 x 5.73" (62.74 x 145.54 mm) opening and UL2808 compliance, standard for busbar.


Veris H6812-1200A-5A Offers

Features

  • Unique hinge design on split-cores, easy installation
  • 5 A standard output, compatible with existing systems
  • UL recognized

Applications

  • Data logging
  • Recording
  • Power monitoring
  • Energy management
  • Alternative energy monitoring
  • Cost allocation

Dimensional Drawings

The Dimensions for the H681 Series of Split Core CTs
H6810/Small (200 A / 300 A)

A = 3.8" (96 mm)
B = 1.2" (30 mm)
C = 1.3" (32 mm)
D = 1.2" (30 mm)
E = 4.0" (100 mm)
F = 4.8" (121 mm)

H6811/Medium (400 A / 600 A / 800 A)

A = 4.9" (125 mm)
B = 2.9" (73 mm)
C = 2.5" (62 mm)
D = 1.2" (30 mm)
E = 5.2" (132 mm)
F = 6.0" (151 mm)

H6811/Large (800 A / 1000 A / 1200 A / 1600 A / 2000 A / 2400 A)

A = 4.9" (125 mm)
B = 5.5" (139 mm)
C = 2.5" (62 mm)
D = 1.2" (30 mm)
E = 7.9" (201 mm)
F = 6.0" (151 mm)

Veris H6812-1200A-5AU Specifications

Accuracy ±1% of reading from 10 to 100% of rated current
Current Measurement Range 0 to 1200 A
Environmental Conditions Humidity Range: 0 to 95% Non-Condensing
Storage Temperature: -40 to 158 °F (-40 to 70°C)
Operating Temperature: 5 to 140 °F (-15 to 60°C)
Frequency Rating 50 to 60 Hz
Mounting Split-Core
Output Specifications 5 A
Dimensions 6 x 7.9 x 1.2" (151 x 201 x 30 mm)
Cliquer ici pour toutes les spécifications du Veris H6812-1200A-5AU

Le Veris H6812-1200A-5AU comprend

  • Veris H6812-1200A-5AU Large Split Core Current Transformer, 1200 A: 5 A

Poser une question sur le Veris H6812-1200A-5AU Large Split Core Current Transformer, 1200 A: 5 A

Veris H6812-1200A-5A Offers

Features

  • Unique hinge design on split-cores, easy installation
  • 5 A standard output, compatible with existing systems
  • UL recognized

Applications

  • Data logging
  • Recording
  • Power monitoring
  • Energy management
  • Alternative energy monitoring
  • Cost allocation

Dimensional Drawings

The Dimensions for the H681 Series of Split Core CTs
H6810/Small (200 A / 300 A)

A = 3.8" (96 mm)
B = 1.2" (30 mm)
C = 1.3" (32 mm)
D = 1.2" (30 mm)
E = 4.0" (100 mm)
F = 4.8" (121 mm)

H6811/Medium (400 A / 600 A / 800 A)

A = 4.9" (125 mm)
B = 2.9" (73 mm)
C = 2.5" (62 mm)
D = 1.2" (30 mm)
E = 5.2" (132 mm)
F = 6.0" (151 mm)

H6811/Large (800 A / 1000 A / 1200 A / 1600 A / 2000 A / 2400 A)

A = 4.9" (125 mm)
B = 5.5" (139 mm)
C = 2.5" (62 mm)
D = 1.2" (30 mm)
E = 7.9" (201 mm)
F = 6.0" (151 mm)

Veris H6812-1200A-5AU Specifications

Accuracy ±1% of reading from 10 to 100% of rated current
Current Measurement Range 0 to 1200 A
Environmental Conditions Humidity Range: 0 to 95% Non-Condensing
Storage Temperature: -40 to 158 °F (-40 to 70°C)
Operating Temperature: 5 to 140 °F (-15 to 60°C)
Frequency Rating 50 to 60 Hz
Mounting Split-Core
Output Specifications 5 A
Dimensions 6 x 7.9 x 1.2" (151 x 201 x 30 mm)
Cliquer ici pour toutes les spécifications du Veris H6812-1200A-5AU

Le Veris H6812-1200A-5AU comprend

  • Veris H6812-1200A-5AU Large Split Core Current Transformer, 1200 A: 5 A

Poser une question sur le Veris H6812-1200A-5AU Large Split Core Current Transformer, 1200 A: 5 A

Plus de produits Veris