Veris EP2100S Electropneumatic Transducer, standard

Modèle: EP2100S

Veris EP2100S Electropneumatic Transducer, standard

Modèle: EP2100S

The electropneumatic transducer combines a microcontroller with high-performance, low power coil poppet valve technology.

The electropneumatic transducer combines a microcontroller with high-performance, low power coil poppet valve technology.

Prix spécial $399.00 CAD
Prix régulier $711.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Veris EP2100S Offers

The electropneumatic transducer combines a microcontroller with high-performance, low power coil poppet valve technology.

Features

  • Field-selectable 4 to 20 mA/0 to 5 V/0 to 10 VDC input for application flexibility
  • Manual override with set and hold feature great for commissioning those leaky systems
  • Multi-point calibration; 3 to 15 psi (5-point calibration) and 0 to 20 psi (6-point calibration)
  • Pressure loss alarm provides a contact closure if the EP is unable to achieve the desired output within a fixed length of time
  • Failsafe vent solenoids bleed branch pressure on power failure for added safety
  • Optional transparent plastic dust cover (AA43) protects units from dust and tampering

Applications

  • Hospitals
  • Schools

Veris EP2100S Specifications

Input Power 24 VAC/DC nominal,30 VAC max; 150 mA max
Control Input 4 to 20 mA/0 to 5 V/0 to 10 VDC (jumper-selectable)
Input Impedance 4 to 20 mA, 250 Ω; 0 to 5 V/0 to 10 VDC, 10k Ω
Manual Override Jumper-selectable mode, digital push-button adjust
Accuracy 1% FS; combined linearity, hysteresis, repeatability
Compensated Temperature Range 25 to 140°F (4 to 65°C)
Temperature Coefficient ±0.05%
Operating Environment 10 to 90% RH non-condensing
Air Capacity 523 in³/min at 45 psi (8,570 cm³/min at 310.3 kPa); 333 in³/min at 20 psi (5,456 cm³/min at 137.9 kPa)
Supply Pressure 45 psig max
Control Range 0 to 20 psig or 3 to 15 psig (jumper-selectable)
Pressure Differential 0.1 psig (supply to branch)
Pressure Indication Electronic, 3.5-digit LCD
Minimum Tubing Length 15' (4.6 m)
Port Connection 0.13" (0.33 cm) ID poly tubing
Media Connection Clean, dry air or inert gas (do not use with oxygen service)
Warranty 5 years limited
Cliquer ici pour toutes les spécifications du Veris EP2100S

Le Veris EP2100S comprend

  • Veris EP2100S Electropneumatic Transducer, standard

Poser une question sur le Veris EP2100S Electropneumatic Transducer, standard

Veris EP2100S Offers

The electropneumatic transducer combines a microcontroller with high-performance, low power coil poppet valve technology.

Features

  • Field-selectable 4 to 20 mA/0 to 5 V/0 to 10 VDC input for application flexibility
  • Manual override with set and hold feature great for commissioning those leaky systems
  • Multi-point calibration; 3 to 15 psi (5-point calibration) and 0 to 20 psi (6-point calibration)
  • Pressure loss alarm provides a contact closure if the EP is unable to achieve the desired output within a fixed length of time
  • Failsafe vent solenoids bleed branch pressure on power failure for added safety
  • Optional transparent plastic dust cover (AA43) protects units from dust and tampering

Applications

  • Hospitals
  • Schools

Veris EP2100S Specifications

Input Power 24 VAC/DC nominal,30 VAC max; 150 mA max
Control Input 4 to 20 mA/0 to 5 V/0 to 10 VDC (jumper-selectable)
Input Impedance 4 to 20 mA, 250 Ω; 0 to 5 V/0 to 10 VDC, 10k Ω
Manual Override Jumper-selectable mode, digital push-button adjust
Accuracy 1% FS; combined linearity, hysteresis, repeatability
Compensated Temperature Range 25 to 140°F (4 to 65°C)
Temperature Coefficient ±0.05%
Operating Environment 10 to 90% RH non-condensing
Air Capacity 523 in³/min at 45 psi (8,570 cm³/min at 310.3 kPa); 333 in³/min at 20 psi (5,456 cm³/min at 137.9 kPa)
Supply Pressure 45 psig max
Control Range 0 to 20 psig or 3 to 15 psig (jumper-selectable)
Pressure Differential 0.1 psig (supply to branch)
Pressure Indication Electronic, 3.5-digit LCD
Minimum Tubing Length 15' (4.6 m)
Port Connection 0.13" (0.33 cm) ID poly tubing
Media Connection Clean, dry air or inert gas (do not use with oxygen service)
Warranty 5 years limited
Cliquer ici pour toutes les spécifications du Veris EP2100S

Le Veris EP2100S comprend

  • Veris EP2100S Electropneumatic Transducer, standard

Poser une question sur le Veris EP2100S Electropneumatic Transducer, standard

Plus de produits Veris