Provides a unique solution for measuring energy data, this power/energy meter is designed with the user in mind. Offers maximum flexibility for retrofit applications, and compact size enables installation in existing panels with limited space, nor does not require external mounting, additional enclosures, or conduit runs.
Provides a unique solution for measuring energy data, this power/energy meter is designed with the user in mind. Offers maximum flexibility for retrofit applications, and compact size enables installation in existing panels with limited space, nor does not require external mounting, additional enclosures, or conduit runs.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:
Visitez notre catégorie Compteurs d’électricité enfichables pour trouver des produits similaires.
Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:
Caractéristiques
Applications
| Measurement Accuracy | |
| Real Power and Energy | 1/3 V current input mode: IEC 62053-22 Class 0.2S, ANSI C12.20 0.2% Rogowski current input mode: IEC 62053-22 Class 0.5S, ANSI C12.20 0.5% |
| Reactive Power and Energy | IEC 62053-23 Class 2, 2% |
| Input Voltage | |
| Measured AC Voltage | Minimum 90 VL-N (156 VL-L) for stated accuracy; UL maximum: 480 VL-L (277 VL-N); CE maximum: 300 VL-N |
| Impedance | 2.5 MΩL-N/5 MΩL-L |
| Frequency Range | 45 to 65 Hz |
| Input Current | |
| Measurement Input Range | 0 to 0.333 V AC (+20% over-range) |
| Impedance | 50 ms at 120 V AC |
| Control Power | |
| AC | 4 VA maximum; 90 V mins UL maximum: 480 VL-L (277 VL-N) CE maximum: 300 VL-N |
| Ride-through Time | 50 ms at 120 V AC |
| General Specifications | |
| Ingress Protection (IEC 60529) | IP20 |
| Plug Wire Size (I/O, Communications, CT) | 24 to 16 AWG (0.2 to 1.5 mm2) |
| Environmental Conditions | Operating temperature: -22 to 158°F (-30 to 70°C) Storage temperature: -40 to 185°F (-40 to 85°C) Humidity range: <95% RH (non-condensing)<br> Altitude: 1.86 mi (3 km) maximum Pollution degree: 2 |
| Dimensions | 6.67 x 1.84 x 1.41" (169.54 x 46.63 x 35.81 mm) |
| Measurement Accuracy | |
| Real Power and Energy | 1/3 V current input mode: IEC 62053-22 Class 0.2S, ANSI C12.20 0.2% Rogowski current input mode: IEC 62053-22 Class 0.5S, ANSI C12.20 0.5% |
| Reactive Power and Energy | IEC 62053-23 Class 2, 2% |
| Input Voltage | |
| Measured AC Voltage | Minimum 90 VL-N (156 VL-L) for stated accuracy; UL maximum: 480 VL-L (277 VL-N); CE maximum: 300 VL-N |
| Impedance | 2.5 MΩL-N/5 MΩL-L |
| Frequency Range | 45 to 65 Hz |
| Input Current | |
| Measurement Input Range | 0 to 0.333 V AC (+20% over-range) |
| Impedance | 50 ms at 120 V AC |
| Control Power | |
| AC | 4 VA maximum; 90 V mins UL maximum: 480 VL-L (277 VL-N) CE maximum: 300 VL-N |
| Ride-through Time | 50 ms at 120 V AC |
| General Specifications | |
| Ingress Protection (IEC 60529) | IP20 |
| Plug Wire Size (I/O, Communications, CT) | 24 to 16 AWG (0.2 to 1.5 mm2) |
| Environmental Conditions | Operating temperature: -22 to 158°F (-30 to 70°C) Storage temperature: -40 to 185°F (-40 to 85°C) Humidity range: <95% RH (non-condensing)<br> Altitude: 1.86 mi (3 km) maximum Pollution degree: 2 |
| Dimensions | 6.67 x 1.84 x 1.41" (169.54 x 46.63 x 35.81 mm) |