UEi TACK20 has DL479 AC 600A True RMS HVAC/R clamp meter, CD100A combustible leak detector, EM152 dual input manometer, PDT550 digital NSF waterproof thermometer, ATTPC3 pipe clamp adapter, ATT70 K-type to input jack adapter, and AC73 carrying case.
UEi TACK20 has DL479 AC 600A True RMS HVAC/R clamp meter, CD100A combustible leak detector, EM152 dual input manometer, PDT550 digital NSF waterproof thermometer, ATTPC3 pipe clamp adapter, ATT70 K-type to input jack adapter, and AC73 carrying case.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n'y a aucune option de remplacement.
Nous pouvons vous aider à trouver ce dont vous avez besoin:
DL479 AC 600A True RMS HVAC/R Clamp Meter
CD100A Combustible Leak Detector
EM152 Dual Input Manometer
PDT550 Digital NSF Waterproof Thermometer
ATTPC3 Pipe Clamp Adapter
| AC Amps - Jaw Input | Range:60A/600A, Resolution: 0.01A/0.1A, Accuracy: ±(2.0% +8 dgts), Overload Protection:600V RMS |
| AC Volts (45Hz to 400Hz) | Range:600mV/6V/60V/600V/750V, Resolution: 0.1mV/1mV/10mV/100mV/1V, Accuracy: ±(1.0% +8 dgts)/±(1.2% +8 dgts), Overload Protection:1000V RMS |
| DC Volts | Range:600mV/6V/60V/600V/600V, Resolution: 0.1mV/1mV/10mV/100mV, Accuracy:±(0.5% +4 dgts), Overload Protection 1000V RMS |
| DC Low Amps | Range:600µA/2000µA, Resolution: 0.1µA/1.0µA, Accuracy: ±(1.2% +3 dgts), Overload Protection:2000µA/600V RMS |
| Resistance | Range:600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ, Resolution: 0.1Ω/1Ω/10Ω/100Ω/0.001MΩ/0.01MΩ, Accuracy: ±(0.8% +3 dgts±(1.2% +3 dgts), Overload Protection:600V RMS |
| Frequency | Range:99.99Hz/999.9Hz/9.999kHz, Resolution: 0.01Hz/0.1Hz/0.001kHz, Accuracy: 1.30mA, Overload Protection:600V RMS |
| Continuity | Open Circuit: <1.0V, Test Current: ±(0.1% per+3 dgts) 6, Overload Protection:600V RMS |
| Duty Cycle | Range: 0.5% to 95% 60Hz to 400Hz/15% to 85% 400Hz to 2kHz, Resolution: 0.1%, Accuracy: ±(0.2% per kHz +2.0% +2 dgts), Overload Protection:600V RMS |
| Diode Test | Range: 4.0V, Resolution: <3.0V DC, Test Current: 1.30mA, Overload Protection:600V RMS |
| Capacitance | Range:60nF/600nF/6.000µF/60.00µF/600.0µF/2000µF, Resolution: 0.01nF/0.1nF/0.001µF/0.01µF/0.1µF/1µF, Accuracy (3.0% +5 dgts), Overload Protection:600V RMS |
| AC Amps - Jaw Input | Range:60A/600A, Resolution: 0.01A/0.1A, Accuracy: ±(2.0% +8 dgts), Overload Protection:600V RMS |
| AC Volts (45Hz to 400Hz) | Range:600mV/6V/60V/600V/750V, Resolution: 0.1mV/1mV/10mV/100mV/1V, Accuracy: ±(1.0% +8 dgts)/±(1.2% +8 dgts), Overload Protection:1000V RMS |
| DC Volts | Range:600mV/6V/60V/600V/600V, Resolution: 0.1mV/1mV/10mV/100mV, Accuracy:±(0.5% +4 dgts), Overload Protection 1000V RMS |
| DC Low Amps | Range:600µA/2000µA, Resolution: 0.1µA/1.0µA, Accuracy: ±(1.2% +3 dgts), Overload Protection:2000µA/600V RMS |
| Resistance | Range:600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ, Resolution: 0.1Ω/1Ω/10Ω/100Ω/0.001MΩ/0.01MΩ, Accuracy: ±(0.8% +3 dgts±(1.2% +3 dgts), Overload Protection:600V RMS |
| Frequency | Range:99.99Hz/999.9Hz/9.999kHz, Resolution: 0.01Hz/0.1Hz/0.001kHz, Accuracy: 1.30mA, Overload Protection:600V RMS |
| Continuity | Open Circuit: <1.0V, Test Current: ±(0.1% per+3 dgts) 6, Overload Protection:600V RMS |
| Duty Cycle | Range: 0.5% to 95% 60Hz to 400Hz/15% to 85% 400Hz to 2kHz, Resolution: 0.1%, Accuracy: ±(0.2% per kHz +2.0% +2 dgts), Overload Protection:600V RMS |
| Diode Test | Range: 4.0V, Resolution: <3.0V DC, Test Current: 1.30mA, Overload Protection:600V RMS |
| Capacitance | Range:60nF/600nF/6.000µF/60.00µF/600.0µF/2000µF, Resolution: 0.01nF/0.1nF/0.001µF/0.01µF/0.1µF/1µF, Accuracy (3.0% +5 dgts), Overload Protection:600V RMS |