TSI EBT731-STA Balometer Capture Hood with stand and tablet

Modèle: EBT731-STA

TSI EBT731-STA Balometer Capture Hood with stand and tablet

Modèle: EBT731-STA

Ergonomic and lightweight, this multipurpose electronic air balancing instrument is ideal for taking accurate, direct air volume measurements at diffusers and grilles. This bundle includes a capture hood, a capture hood stand, and a smart tablet loaded with LogDat™ software and instruction videos.

Ergonomic and lightweight, this multipurpose electronic air balancing instrument is ideal for taking accurate, direct air volume measurements at diffusers and grilles. This bundle includes a capture hood, a capture hood stand, and a smart tablet loaded with LogDat™ software and instruction videos.

Ce produit excède les dimensions/poids de livraison standard, donc il ne se qualifie pas pour la livraison gratuite. Nous vous contacterons avec vos frais de livraisons.

Prix régulier $5620.00 CAD
Disponibilité 15+ semaines
Quantité

TSI/Alnor EBT731-STA Offers

Offering durable, trouble-free operation, this lightweight, ergonomically designed capture hood kit saves time and money by combining multiple measurement tools into one package. The balometer capture hood helps you create healthy and energy efficient environments while meeting local codes, guidelines and regulations for ventilation systems.

The capture hood features a detachable micromanometer which can be used with optional probes for increased flexibility in multiple measurement applications.

Features

  • Ergonomic, lightweight design enables easy one-person operation
  • Automatic sensing and display of supply or return flows saves time on the job
  • Back pressure compensation ensures accurate readings at high flow rates
  • Detachable digital micromanometer provides additional measurement capability
  • Multiple hood size options enable measurement of different outlet dimensions
  • Compatible LogDat Mobile Remote Reader and Data Logger Software simplifies documenting of results and emailing of reports
  • Capture hood stand eliminates the need for ladders (reaching diffusers up to 15')

Applications

  • Test and balance contractors
  • Commissioning agents
  • Facilities managers
  • Health and safety specialists
  • Ventilation system installers

TSI/Alnor EBT731-STA Specifications

Velocity Range
Pitot Probes 25 to 15,500 ft/min (0.125 to 78 m/s)
Air Flow Probe 25 to 5,000 ft/min (0.125 to 25 m/s)
Velocity Matrix 25 to 2,500 ft/min (0.125 to 12.5 m/s)
Accuracy ±3% of reading ±7 ft/min (±0.04 m/s) at velocities >50 ft/min (>0.25 m/s)
Resolution 1 ft/min (0.01 m/s)
Pressure
Differential Pressure ±15 inH2O (±3735 Pa)
150 inH2O (37.5 kPa)
Maximum safe operating pressure
Absolute Pressure 15 to 40 inHg (356 to 1016 mmHg)
Accuracy ±2% of reading ±0.0001 inH2O (±0.025 Pa) static and differential
±2% of reading absolute
Resolution 0.00001 inH2O (0.001 Pa) static and differential
0.01 inHg (1 mmHg) absolute
General Specifications
Instrument Temperature Range Operating: 40 to 140°F (4.4 to 60°C)
Storage: -4 to 160°F (-20 to 71°C)
Weight 7.4 lbs (3.4 kg)
Cliquer ici pour toutes les spécifications du TSI/Alnor EBT731-STA

What's included with the TSI/Alnor EBT731-STA

  • Capture Hood
  • NIST-Traceable Calibration Certificate
  • Capture Hood Stand
  • Tablet with LogDat™ Software and Instruction Videos
  • Air Capture Hood/Frame/Base, 2 x 2' (61 x 61 cm)
  • Detachable Micromanometer
  • Multi-Country AC Adapter
  • Pitot Probe, 18" (46 cm)
  • 2 x Static Pressure Probes
  • Neoprene Tubing, 16' (4.8 m)
  • USB Interface Cable
  • Downloading Software
  • Wheeled Luggage-Style Carrying Case
  • 4 x AA Rechargeable NiMH Batteries
  • Product Manual

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le TSI EBT731-STA Balometer Capture Hood with stand and tablet.

Dwyer 160-12 Tube pilote, insertion de 12" 160-12
Idéal pour utiliser avec nos manomètres de précision et les jauges de la vélocité de l'air. Conception ASME qui rencontre les exigences AMCA et ASHRA offrant une précision maximale pour une grande varieté de conditions. Nul besoin de coeffecient de correction puisque la pointe conçue par ASHRAE produit un coefficent d'étallonage de 1. La technique ASHRAE n'a pas besoin d'étalonnage. Diamètre standard de 5/16".




Dwyer 160-60 Tube pilote, insertion de 60" 160-60
Idéal pour utiliser avec nos manomètres de précision et les jauges de la vélocité de l'air. Conception ASME qui rencontre les exigences AMCA et ASHRA offrant une précision maximale pour une grande varieté de conditions. Nul besoin de coeffecient de correction puisque la pointe conçue par ASHRAE produit un coefficent d'étallonage de 1. La technique ASHRAE n'a pas besoin d'étalonnage. Diamètre standard de 5/16".




Dwyer 160-36 Tube pilote, insertion de 36" 160-36
Idéal pour utiliser avec nos manomètres de précision et les jauges de la vélocité de l'air. Conception ASME qui rencontre les exigences AMCA et ASHRA offrant une précision maximale pour une grande varieté de conditions. Nul besoin de coeffecient de correction puisque la pointe conçue par ASHRAE produit un coefficent d'étallonage de 1. La technique ASHRAE n'a pas besoin d'étalonnage. Diamètre standard de 5/16".




Dwyer 160-24 Tube pilote, insertion de 24" 160-24
Idéal pour utiliser avec nos manomètres de précision et les jauges de la vélocité de l'air. Conception ASME qui rencontre les exigences AMCA et ASHRA offrant une précision maximale pour une grande varieté de conditions. Nul besoin de coeffecient de correction puisque la pointe conçue par ASHRAE produit un coefficent d'étallonage de 1. La technique ASHRAE n'a pas besoin d'étalonnage. Diamètre standard de 5/16".




Dwyer 160-18 Tube pilote, insertion de 18" 160-18
Idéal pour utiliser avec nos manomètres de précision et les jauges de la vélocité de l'air. Conception ASME qui rencontre les exigences AMCA et ASHRA offrant une précision maximale pour une grande varieté de conditions. Nul besoin de coeffecient de correction puisque la pointe conçue par ASHRAE produit un coefficent d'étallonage de 1. La technique ASHRAE n'a pas besoin d'étalonnage. Diamètre standard de 5/16".












TSI/Alnor 801090 Matrice de vélocité en 16 points 801090
Pour le TSI/Alnor EBT731. Gamme de vélocité de 25 à 2500 pi/min (0.125 à 12.5m/s).




TSI/Alnor 800187 Sonde de vélocité de l'air 800187
Pour le TSI/Alnor EBT731. Gamme de vélocité de 25 à 5000 pi/min (0.125 à 25m/s).




Poser une question sur le TSI EBT731-STA Balometer Capture Hood with stand and tablet

TSI/Alnor EBT731-STA Offers

Offering durable, trouble-free operation, this lightweight, ergonomically designed capture hood kit saves time and money by combining multiple measurement tools into one package. The balometer capture hood helps you create healthy and energy efficient environments while meeting local codes, guidelines and regulations for ventilation systems.

The capture hood features a detachable micromanometer which can be used with optional probes for increased flexibility in multiple measurement applications.

Features

  • Ergonomic, lightweight design enables easy one-person operation
  • Automatic sensing and display of supply or return flows saves time on the job
  • Back pressure compensation ensures accurate readings at high flow rates
  • Detachable digital micromanometer provides additional measurement capability
  • Multiple hood size options enable measurement of different outlet dimensions
  • Compatible LogDat Mobile Remote Reader and Data Logger Software simplifies documenting of results and emailing of reports
  • Capture hood stand eliminates the need for ladders (reaching diffusers up to 15')

Applications

  • Test and balance contractors
  • Commissioning agents
  • Facilities managers
  • Health and safety specialists
  • Ventilation system installers

TSI/Alnor EBT731-STA Specifications

Velocity Range
Pitot Probes 25 to 15,500 ft/min (0.125 to 78 m/s)
Air Flow Probe 25 to 5,000 ft/min (0.125 to 25 m/s)
Velocity Matrix 25 to 2,500 ft/min (0.125 to 12.5 m/s)
Accuracy ±3% of reading ±7 ft/min (±0.04 m/s) at velocities >50 ft/min (>0.25 m/s)
Resolution 1 ft/min (0.01 m/s)
Pressure
Differential Pressure ±15 inH2O (±3735 Pa)
150 inH2O (37.5 kPa)
Maximum safe operating pressure
Absolute Pressure 15 to 40 inHg (356 to 1016 mmHg)
Accuracy ±2% of reading ±0.0001 inH2O (±0.025 Pa) static and differential
±2% of reading absolute
Resolution 0.00001 inH2O (0.001 Pa) static and differential
0.01 inHg (1 mmHg) absolute
General Specifications
Instrument Temperature Range Operating: 40 to 140°F (4.4 to 60°C)
Storage: -4 to 160°F (-20 to 71°C)
Weight 7.4 lbs (3.4 kg)
Cliquer ici pour toutes les spécifications du TSI/Alnor EBT731-STA

What's included with the TSI/Alnor EBT731-STA

  • Capture Hood
  • NIST-Traceable Calibration Certificate
  • Capture Hood Stand
  • Tablet with LogDat™ Software and Instruction Videos
  • Air Capture Hood/Frame/Base, 2 x 2' (61 x 61 cm)
  • Detachable Micromanometer
  • Multi-Country AC Adapter
  • Pitot Probe, 18" (46 cm)
  • 2 x Static Pressure Probes
  • Neoprene Tubing, 16' (4.8 m)
  • USB Interface Cable
  • Downloading Software
  • Wheeled Luggage-Style Carrying Case
  • 4 x AA Rechargeable NiMH Batteries
  • Product Manual

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le TSI EBT731-STA Balometer Capture Hood with stand and tablet.

Dwyer 160-12 Tube pilote, insertion de 12" 160-12
Idéal pour utiliser avec nos manomètres de précision et les jauges de la vélocité de l'air. Conception ASME qui rencontre les exigences AMCA et ASHRA offrant une précision maximale pour une grande varieté de conditions. Nul besoin de coeffecient de correction puisque la pointe conçue par ASHRAE produit un coefficent d'étallonage de 1. La technique ASHRAE n'a pas besoin d'étalonnage. Diamètre standard de 5/16".




Dwyer 160-60 Tube pilote, insertion de 60" 160-60
Idéal pour utiliser avec nos manomètres de précision et les jauges de la vélocité de l'air. Conception ASME qui rencontre les exigences AMCA et ASHRA offrant une précision maximale pour une grande varieté de conditions. Nul besoin de coeffecient de correction puisque la pointe conçue par ASHRAE produit un coefficent d'étallonage de 1. La technique ASHRAE n'a pas besoin d'étalonnage. Diamètre standard de 5/16".




Dwyer 160-36 Tube pilote, insertion de 36" 160-36
Idéal pour utiliser avec nos manomètres de précision et les jauges de la vélocité de l'air. Conception ASME qui rencontre les exigences AMCA et ASHRA offrant une précision maximale pour une grande varieté de conditions. Nul besoin de coeffecient de correction puisque la pointe conçue par ASHRAE produit un coefficent d'étallonage de 1. La technique ASHRAE n'a pas besoin d'étalonnage. Diamètre standard de 5/16".




Dwyer 160-24 Tube pilote, insertion de 24" 160-24
Idéal pour utiliser avec nos manomètres de précision et les jauges de la vélocité de l'air. Conception ASME qui rencontre les exigences AMCA et ASHRA offrant une précision maximale pour une grande varieté de conditions. Nul besoin de coeffecient de correction puisque la pointe conçue par ASHRAE produit un coefficent d'étallonage de 1. La technique ASHRAE n'a pas besoin d'étalonnage. Diamètre standard de 5/16".




Dwyer 160-18 Tube pilote, insertion de 18" 160-18
Idéal pour utiliser avec nos manomètres de précision et les jauges de la vélocité de l'air. Conception ASME qui rencontre les exigences AMCA et ASHRA offrant une précision maximale pour une grande varieté de conditions. Nul besoin de coeffecient de correction puisque la pointe conçue par ASHRAE produit un coefficent d'étallonage de 1. La technique ASHRAE n'a pas besoin d'étalonnage. Diamètre standard de 5/16".












TSI/Alnor 801090 Matrice de vélocité en 16 points 801090
Pour le TSI/Alnor EBT731. Gamme de vélocité de 25 à 2500 pi/min (0.125 à 12.5m/s).




TSI/Alnor 800187 Sonde de vélocité de l'air 800187
Pour le TSI/Alnor EBT731. Gamme de vélocité de 25 à 5000 pi/min (0.125 à 25m/s).




Poser une question sur le TSI EBT731-STA Balometer Capture Hood with stand and tablet

Plus de produits TSI/Alnor