TREND Networks R240-PMLS FiberMASTER Multimode and Single-Mode Power Meter and Quad Light Source Kit, VFL

Modèle: R240-PMLS | CUP: 5056310400974

TREND Networks R240-PMLS FiberMASTER Multimode and Single-Mode Power Meter and Quad Light Source Kit, VFL

Modèle: R240-PMLS | CUP: 5056310400974

This unit measures attenuation in MM and SM cabling. It is compatible with the auto-centering, pass and fail video probe.

This unit measures attenuation in MM and SM cabling. It is compatible with the auto-centering, pass and fail video probe.

Prix spécial $5029.00 CAD
Prix régulier $5350.00 CAD
Disponibilité 2 à 3 semaines
Quantité

TREND Networks R240-PMLS offre

Test, troubleshoot, and certify cabling faster with the FiberMASTER OTDR.. The FiberMASTER OTDR is available in 4 options: Quad, multimode, singlemode, and PON.. The OTDRs feature both high dynamic range and small dead zones, providing the precision required for installation and troubleshooting alike.

Instant results using the FiberMASTER Power Meter (PM) and Light Source (LS).

The power meter and light source is used to measure attenuation in multimode or single-mode cabling. The power meter’s high dynamic range also allows for troubleshooting of LAN and Telecom networks. Both the power meter and light source support the fiber inspection probe to capture images of the connector on each end of the cabling.

All OTDRs include a power meter and when partnered with a FiberMASTER light source, the OTDR can be used to directly measure cable attenuation or to measure the output power of optical equipment for troubleshooting.

The fiber Inspection Probe with Automatic Certification to IEC61300-3-35 Standard. 90% of all fiber optic cable and network issues arise from dirty and/or damaged fiber connectors which is why the Fiber Inspection Probe is an essential piece of equipment for any fiber cable installer or technician.

  • Accuracy verified by test lab, GHMT: Distance accuracy verified by German test laboratory, GHMT AG in accordance with the Telcordia GR-196 specifications.
  • Industry leading Dynamic Range: Test longer fibers, PON systems and maintain accuracy on high-loss fibers.
  • Built to last: We've surrounded FiberMASTER with a thick rubber housing. Protecting your investment and reducing downtime.
  • Start testing faster: There is no boot up time or delay. Simply turn on and start testing.
  • Minimal training time: The touchscreen user interface will guide you through the setup and testing process to reduce potential mistakes, as well as save time in training field technicians.

Caractéristiques

  • Measure Attenuation in MM and SM cabling
  • High Dynamic Range for better troubleshooting
  • Pass and Fail report to TIA/ISO/IEC/IEEE
  • Free CertSoft PC Reporting Software
  • Optional Fiber Inspection Probe
  • ORL measurement range to -60 dB
  • 82 dB power meter dynamic range
  • Compatible with the auto-centering/Pass/Fail video probe
  • Auto test up to three wavelengths

Spécifications pour le TREND Networks R240-PMLS

OTDR
Wavelength 850, 1300, 1310, 1550, 1625 nm
Dynamic Range (dB) 29/30 MM, 38/37 SM, 37/37/36 PON
Dead Zones 1 m Event, 5 m Attenuation
Resolution 2" to 52' (6 cm to 16 m)
Distance uncertainty ±(0.75 m + 0.005% x distance + sampling resolution) Verified by GHMT laboratories
Sampling points Up to 128,000
Storage Approximately 40,000 results
Connector SC included FC, ST optional
Power Meter
Wavelength 850, 1300, 1310, 1550, 1625 nm
Measurement Range +5 to -77 dBm
Uncertainty ±0.18 dB reference conditions
±0.25 dB from 0 to -65 dBm
±0.35dB from 0 to +5 dBm
±0.35 dB - 65 to -77 dBm
Resolution 0.01 dB
Connectors LC, SC, FC, ST, 2.5 mm, and 1.25 mm included
General Specifications
Interfaces I/O Other, USB
Battery Type AAA
Power Supply Voltage Battery powered
Dimensions 6.7 x 2 x 4.25" (17.02 x 5.08 x 10.80 cm)
Weight 5 lbs (2.3 kg)

Le TREND Networks R240-PMLS comprend

  • FiberMASTER Multimode and Single-Mode Power Meter and Quad Light Source Kit
  • Inspection port
  • Visual Fault Finder
  • FiberMASTER Quad light source with LC connectors
  • Inspection port
  • Visual Fault Locator
  • 2 x Power Adapter
  • 2 x USB Cable
  • 4 x Stylus
  • 1 x Carry Case
  • 2 x Hanging Strap
  • 4 x Cleaning Pen, 2 x 1.25mm and 2 x 2.5mm
  • 2 x MM 2m Cable LC-SC
  • 2 x MM 2m Cable SC-SC
  • 2 x SM 2m Cable LC-SC
  • 2 x SM 2m Cable SC-SC
  • Power Meter Connectors (LC, SC, FC, ST, 1.25 mm UNIV, 2.5 mm UNIV)
  • 1 x Quick Reference Guide

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le TREND Networks R240-PMLS FiberMASTER Multimode and Single-Mode Power Meter and Quad Light Source Kit, VFL.

TREND Networks R240-ML-SCLC Câble d'amorce multimode pour testeurs de fibre optique FiberMASTER, OM3, SC-LC R240-ML-SCLC
Ce câble d'amorce est utilisé pour se connecter au testeur de fibre optique FiberMASTER de l'utilisateur afin de mesurer la perte et la réflexion de la première connexion sur la liaison. Ce câble permet à l'instrument de se rétablir après l'envoi de l'impulsion de test à travers la fibre.




TREND Networks R164051 Câble à flux inscrit (Encircled Flux) 50/125 um SC à LC pour unités LanTEK IV, FiberTEK III et FiberTEK IV R164051
Le TREND Networks R164051 est un câble à flux inscrit (Encircled Flux) 50/125um SC utilisé pour le FiberTEK III.




TREND Networks R164050 Câble Encircled Flux 50/125 um SC à SC pour unités LanTEK IV, FiberTEK III et FiberTEK IV R164050
Le TREND Networks R164050 est un câble Encircled Flux 50/125um SC utilisé pour le FiberTEK III.




TREND Networks R240-SL-SCSC-A Câble d'amorce monomode pour testeurs de fibre optique FiberMASTER, G.657 A1, SC-SC APC R240-SL-SCSC-A
Ce câble d'amorce est utilisé pour se connecter au testeur de fibre optique FiberMASTER de l'utilisateur afin de mesurer la perte et la réflexion de la première connexion sur la liaison. Ce câble permet à l'instrument de se rétablir après l'envoi de l'impulsion de test à travers la fibre.




TREND Networks R240-SL-SCSC Câble d'amorce monomode pour testeurs de fibre optique FiberMASTER, G.657 A1, SC-SC R240-SL-SCSC
Ce câble d'amorce est utilisé pour se connecter au testeur de fibre optique FiberMASTER de l'utilisateur afin de mesurer la perte et la réflexion de la première connexion sur la liaison. Ce câble permet à l'instrument de récupérer après l'envoi de l'impulsion de test à travers la fibre.




TREND Networks R240-SL-SCLC Câble d'amorce monomode pour testeurs de fibre optique FiberMASTER, G.657 A1, SC-LC R240-SL-SCLC
Ce câble d'amorce est utilisé pour se connecter au testeur de fibre optique FiberMASTER de l'utilisateur afin de mesurer la perte et la réflexion de la première connexion sur la liaison. Ce câble permet à l'instrument de récupérer après l'envoi de l'impulsion de test à travers la fibre.




TREND Networks R240-ML-SCST Multimode Launch Cable for FiberMASTER fiber optic testers, OM3, SC-ST R240-ML-SCST
This launch cable is used to connect to the user's FiberMASTER Fiber Optic Tester to measure the loss and reflection of the first connection on the link. This cable allows the instrument to recover after the test pulse is sent through the fiber.




TREND Networks R240-ML-SCSC Câble d'amorce multimode pour testeurs de fibre optique FiberMASTER, OM3, SC-SC R240-ML-SCSC
Ce câble d'amorce est utilisé pour se connecter au testeur de fibre optique FiberMASTER de l'utilisateur afin de mesurer la perte et la réflexion de la première connexion sur la liaison. Ce câble permet à l'instrument de récupérer après l'envoi de l'impulsion de test à travers la fibre.




TREND Networks R164057 Ensemble de câbles SC/PC/SM 9/125 um pour unités FiberTEK III R164057
Le TREND Networks R164057 est un câble à flux inscrit (Encircled Flux) SC/PC/SM 9/125 um utilisé pour FiberTEK III.




Poser une question sur le TREND Networks R240-PMLS FiberMASTER Multimode and Single-Mode Power Meter and Quad Light Source Kit, VFL

TREND Networks R240-PMLS offre

Test, troubleshoot, and certify cabling faster with the FiberMASTER OTDR.. The FiberMASTER OTDR is available in 4 options: Quad, multimode, singlemode, and PON.. The OTDRs feature both high dynamic range and small dead zones, providing the precision required for installation and troubleshooting alike.

Instant results using the FiberMASTER Power Meter (PM) and Light Source (LS).

The power meter and light source is used to measure attenuation in multimode or single-mode cabling. The power meter’s high dynamic range also allows for troubleshooting of LAN and Telecom networks. Both the power meter and light source support the fiber inspection probe to capture images of the connector on each end of the cabling.

All OTDRs include a power meter and when partnered with a FiberMASTER light source, the OTDR can be used to directly measure cable attenuation or to measure the output power of optical equipment for troubleshooting.

The fiber Inspection Probe with Automatic Certification to IEC61300-3-35 Standard. 90% of all fiber optic cable and network issues arise from dirty and/or damaged fiber connectors which is why the Fiber Inspection Probe is an essential piece of equipment for any fiber cable installer or technician.

  • Accuracy verified by test lab, GHMT: Distance accuracy verified by German test laboratory, GHMT AG in accordance with the Telcordia GR-196 specifications.
  • Industry leading Dynamic Range: Test longer fibers, PON systems and maintain accuracy on high-loss fibers.
  • Built to last: We've surrounded FiberMASTER with a thick rubber housing. Protecting your investment and reducing downtime.
  • Start testing faster: There is no boot up time or delay. Simply turn on and start testing.
  • Minimal training time: The touchscreen user interface will guide you through the setup and testing process to reduce potential mistakes, as well as save time in training field technicians.

Caractéristiques

  • Measure Attenuation in MM and SM cabling
  • High Dynamic Range for better troubleshooting
  • Pass and Fail report to TIA/ISO/IEC/IEEE
  • Free CertSoft PC Reporting Software
  • Optional Fiber Inspection Probe
  • ORL measurement range to -60 dB
  • 82 dB power meter dynamic range
  • Compatible with the auto-centering/Pass/Fail video probe
  • Auto test up to three wavelengths

Spécifications pour le TREND Networks R240-PMLS

OTDR
Wavelength 850, 1300, 1310, 1550, 1625 nm
Dynamic Range (dB) 29/30 MM, 38/37 SM, 37/37/36 PON
Dead Zones 1 m Event, 5 m Attenuation
Resolution 2" to 52' (6 cm to 16 m)
Distance uncertainty ±(0.75 m + 0.005% x distance + sampling resolution) Verified by GHMT laboratories
Sampling points Up to 128,000
Storage Approximately 40,000 results
Connector SC included FC, ST optional
Power Meter
Wavelength 850, 1300, 1310, 1550, 1625 nm
Measurement Range +5 to -77 dBm
Uncertainty ±0.18 dB reference conditions
±0.25 dB from 0 to -65 dBm
±0.35dB from 0 to +5 dBm
±0.35 dB - 65 to -77 dBm
Resolution 0.01 dB
Connectors LC, SC, FC, ST, 2.5 mm, and 1.25 mm included
General Specifications
Interfaces I/O Other, USB
Battery Type AAA
Power Supply Voltage Battery powered
Dimensions 6.7 x 2 x 4.25" (17.02 x 5.08 x 10.80 cm)
Weight 5 lbs (2.3 kg)

Le TREND Networks R240-PMLS comprend

  • FiberMASTER Multimode and Single-Mode Power Meter and Quad Light Source Kit
  • Inspection port
  • Visual Fault Finder
  • FiberMASTER Quad light source with LC connectors
  • Inspection port
  • Visual Fault Locator
  • 2 x Power Adapter
  • 2 x USB Cable
  • 4 x Stylus
  • 1 x Carry Case
  • 2 x Hanging Strap
  • 4 x Cleaning Pen, 2 x 1.25mm and 2 x 2.5mm
  • 2 x MM 2m Cable LC-SC
  • 2 x MM 2m Cable SC-SC
  • 2 x SM 2m Cable LC-SC
  • 2 x SM 2m Cable SC-SC
  • Power Meter Connectors (LC, SC, FC, ST, 1.25 mm UNIV, 2.5 mm UNIV)
  • 1 x Quick Reference Guide

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le TREND Networks R240-PMLS FiberMASTER Multimode and Single-Mode Power Meter and Quad Light Source Kit, VFL.

TREND Networks R240-ML-SCLC Câble d'amorce multimode pour testeurs de fibre optique FiberMASTER, OM3, SC-LC R240-ML-SCLC
Ce câble d'amorce est utilisé pour se connecter au testeur de fibre optique FiberMASTER de l'utilisateur afin de mesurer la perte et la réflexion de la première connexion sur la liaison. Ce câble permet à l'instrument de se rétablir après l'envoi de l'impulsion de test à travers la fibre.




TREND Networks R164051 Câble à flux inscrit (Encircled Flux) 50/125 um SC à LC pour unités LanTEK IV, FiberTEK III et FiberTEK IV R164051
Le TREND Networks R164051 est un câble à flux inscrit (Encircled Flux) 50/125um SC utilisé pour le FiberTEK III.




TREND Networks R164050 Câble Encircled Flux 50/125 um SC à SC pour unités LanTEK IV, FiberTEK III et FiberTEK IV R164050
Le TREND Networks R164050 est un câble Encircled Flux 50/125um SC utilisé pour le FiberTEK III.




TREND Networks R240-SL-SCSC-A Câble d'amorce monomode pour testeurs de fibre optique FiberMASTER, G.657 A1, SC-SC APC R240-SL-SCSC-A
Ce câble d'amorce est utilisé pour se connecter au testeur de fibre optique FiberMASTER de l'utilisateur afin de mesurer la perte et la réflexion de la première connexion sur la liaison. Ce câble permet à l'instrument de se rétablir après l'envoi de l'impulsion de test à travers la fibre.




TREND Networks R240-SL-SCSC Câble d'amorce monomode pour testeurs de fibre optique FiberMASTER, G.657 A1, SC-SC R240-SL-SCSC
Ce câble d'amorce est utilisé pour se connecter au testeur de fibre optique FiberMASTER de l'utilisateur afin de mesurer la perte et la réflexion de la première connexion sur la liaison. Ce câble permet à l'instrument de récupérer après l'envoi de l'impulsion de test à travers la fibre.




TREND Networks R240-SL-SCLC Câble d'amorce monomode pour testeurs de fibre optique FiberMASTER, G.657 A1, SC-LC R240-SL-SCLC
Ce câble d'amorce est utilisé pour se connecter au testeur de fibre optique FiberMASTER de l'utilisateur afin de mesurer la perte et la réflexion de la première connexion sur la liaison. Ce câble permet à l'instrument de récupérer après l'envoi de l'impulsion de test à travers la fibre.




TREND Networks R240-ML-SCST Multimode Launch Cable for FiberMASTER fiber optic testers, OM3, SC-ST R240-ML-SCST
This launch cable is used to connect to the user's FiberMASTER Fiber Optic Tester to measure the loss and reflection of the first connection on the link. This cable allows the instrument to recover after the test pulse is sent through the fiber.




TREND Networks R240-ML-SCSC Câble d'amorce multimode pour testeurs de fibre optique FiberMASTER, OM3, SC-SC R240-ML-SCSC
Ce câble d'amorce est utilisé pour se connecter au testeur de fibre optique FiberMASTER de l'utilisateur afin de mesurer la perte et la réflexion de la première connexion sur la liaison. Ce câble permet à l'instrument de récupérer après l'envoi de l'impulsion de test à travers la fibre.




TREND Networks R164057 Ensemble de câbles SC/PC/SM 9/125 um pour unités FiberTEK III R164057
Le TREND Networks R164057 est un câble à flux inscrit (Encircled Flux) SC/PC/SM 9/125 um utilisé pour FiberTEK III.




Poser une question sur le TREND Networks R240-PMLS FiberMASTER Multimode and Single-Mode Power Meter and Quad Light Source Kit, VFL

Plus de produits TREND Networks