TREND Networks LT4-500FOS offre
The Trend Networks LanTEK IV-S is a powerful and fast 500MHz cable certifier that features industry-leading performance, reliability, durability, and time-saving functionality. The LanTEK IV-S 500 MHz features innovative VisiLINQ permanent link adapters that allow a user to operate the certifier and quickly see the results without holding the handsets. Engineers and technicians can conduct and save a Cat6A test within 7 seconds, assisted by the intuitive user interface and easy-to-use high-resolution touchscreen. The Trend Network LanTEK IV-S 500MHz LT4-500FOS Cable Certifier includes the LanTEK IV-S 500MHz, the FiberTEK IV, and the FiberMaster OTDR. Bundle LT4-500FOS - LanTEK IV-S 500MHz + FiberTEK IV + FiberMaster OTDR + 2 Years Sapphire Care Plan. New Diagnostic Feature DCRU - DC Resistance Unbalance Testing for PoE More PoE applications = more challenges in diagnosing cable faults. However, LanTEK IV-S comes with DCRU testing capability. The LanTEK IV-500MHz LT4-500FOS is a special bundle offer that extends the one-year Sapphire Care Plan included with the purchase to 2 years of care and free calibration service for the same price - that is an additional year for free. The Sapphire Care Plan is an exceptional opportunity to keep your LanTEK cable certifier certified and in top working condition without any downtime.
Caractéristiques
- 500 MHz for Cat 6A/class EA and Class FA
- VisiLINQ permanent link adapters
- 7 second test for 500 MHz tests
- All auto tests perform TLC, ELTCTL, DC resistance unbalance, Time Domain NEXT troubleshooting and Time Domain Return Loss troubleshooting with no extra test time
- Storage for up to 5000 test internally
- Extremely durable test adapters that are captured by the instrument to prevent connector damage
- Can operate from AC main power with or without the battery installed
- High-resolution capacitive touch color display
- Integrated Wi-Fi (2.4/5 GHz 801.11b/g/n) connectivity. Models available with Wi-Fi permanently disabled
- Intuitive user interface to reduce training and testing time
- Trend AnyWARE Cloud and Desktop reporting systems simplify reporting and project management
- FiberTEK IV - Fiber Certification Adapter for the LanTEK IV-SThe FiberTEK IV adapters are used with the LandTEK IV-S for fast and simple certification of high bandwidth single-mode and multimode fiber optic cabling. To pinpoint fiber cabling faults every FiberTEK IV adapter includes a built-in visible light source to help you pinpoint faults and locate fiber ports. FiberTEK IV -
- Attenuation/insertion loss (dB) measurement
- Multimode and single-mode options
- Encircled Flux compliant (optional)
- Built-in visible light source for troubleshooting
- Full Tier 1 fiber certification
- Complies with TIA/ISO/IEC
- FiberMASTER Quad OTDR (850/1300/1310/1550) with SC connectors, Inspection port, Power meter
- Tier 2 Certifier
- One of the world's smallest OTDRs
- ORL measurement range to -60"dB
- Compatible with the auto-centering/Pass/Fail video probe
- Pass/Fail report to TIA/ISO/IEC/IEEE
- 82 dB power meter dynamic range
- Auto test up to three wavelengths
- Distance accuracy verified by German test lab
- Free CertSoft PC Reporting Software
- The Sapphire Care Plan is designed to help minimize down time, reduce the cost of ownership and protect against unforeseen repair bills.
- Free Annual Calibration - Maintain Accuracy
- Free Repairs - Protect Against Unforeseen Bills
- Free Loan Unit During Repairs and Calibration - No Downtime
- Free Online Training and Technical Support - Improve Efficiency
- Free Shipping - Reduce Costs
- Free Replaceable Wear Parts - Reduce Cost of Ownership
- Every year choose from one of the following options.
- 4 x Permanent Link Adapter Tips (Pair)
- 4 x CAT6A Reference Patch Cord (Single)
- 2 x CAT6A Channel Adapter (Single)
- 1 x LanTEK III/IV-S Battery (Single)
- 7 second test time for Cat 6A
- Dual-core CPU
- Twice as much RAM
- Tests up to 500MHz
- 3.0 Software/Operating System
- Performs rapid wiremap
- Detects cross talk and finds return loss faults
- Unique VisiLINQO permanent link adapters
- Field replaceable permanent link adapter tips
- Measures TCL and Resistance Unbalance
- TDRL and TDX troubleshooting
- Voltage protection from PoE sources
- Battery life: 8 hr. typical
- Can operate from AC main power with or without the battery installed
- Pre-configuration eliminates setup error
- USB, Wi-Fi
- Sapphire Care Plan minimizes costs
- Voltage protection
- Live wiremap
- Label printer connectivity
- Integrated kickstand
- Rugged Design
- Performs all extended measurements
- High impact touchscreen
- Intuitive User interface
- Storage for up to 5000 tests internally
- Provides audible tone and visible indicator when connected to the remote unit
- Team viewer live support
Applications
- Testing of twisted pair data cabling in LAN and campus applications
- Small electrician who install "data"
- Equipment manufactures (shipyards, patch cable manufacturers)
- Facility maintenance personal of large enterprises (banks, insurances)
- Public sector (army)
- Professional testing and troubleshooting companies
- Installation of data cabling for:
- commercial building
- LAN infrastructure
- Data centers
- building automation
- industrial Ethernet