TPI 775 Combination Carbon Monoxide & Combustion Gas Leak Detector

Modèle: 775 | CUP: 637623007750

TPI 775 Combination Carbon Monoxide & Combustion Gas Leak Detector-


Télécharger: datasheet manual

Plus de produits TPI

Demander à un expert

TPI 775 Combination Carbon Monoxide & Combustion Gas Leak Detector

Modèle: 775 | CUP: 637623007750

Combining both detection technologies into one easy to use hand-held instrument.

Combining both detection technologies into one easy to use hand-held instrument.

Prix spécial $384.35 CAD
Prix régulier $427.05 CAD
Disponibilité 1 Semaine
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre 775 Combination Carbon Monoxide & Combustion Gas Leak Detector

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre 775 Combination Carbon Monoxide & Combustion Gas Leak Detector

TPI 775 Offers

This combination of instruments is the first of its kind. All packaged into one easy to use instrument.

Features

  • One hand operation
  • Auto Zero
  • Display backlight
  • Both visual and audible alarm notification

Good To know

Don't expose yourself to Carbon Monoxide! Review the list below for the maximum allowable exposure limits and symptoms developed with CO inhalation.

  • 9ppm: The maximum allowable concentration for short term exposure in a living area according to ASHRAE
  • 50ppm: The Federal OSHA standard for continuous exposure in any eight hour period
  • 200ppm*: Maximum concentration allowable any time according to OSHA. Slight headaches, fatigue, dizziness, nausea after 2-3 hours
  • 400ppm*: Frontal headaches within 1-2 hours, life threatening after 3 hours. Maximum allowable limit in flue gas according to EPA and AGA
  • 800ppm*: Headache, dizziness, nausea, and convulsions with 45 minutes. Unconsciousness within 2 hours. Death within 2-3 minutes
  • 1600ppm*: Headache, dizziness, and nausea within 20 minutes. Death within 1 hour
  • 3200ppm*: Headache, dizziness, and nausea within 5-10 minutes. Death within 30 minutes
  • 6400ppm*: Headache, dizziness, and nausea within 1-2 minutes. Death within 10-15 minutes
  • 12800ppm*: Death within 1-3 minutes

* With exposure to this concentration and higher the effects can vary depending on size, age, sex, and health.

TPI 775 Specifications

Carbon Monoxide (CO) Measurement Range 0 ~ 2,000ppm
Accuracy ±5ppm or 5% of reading whichever is greater
Resolution 1ppm
Data Storage No
IR Printer Port No
Flue Probe No
Internal Pump No
Combustible Gas Leak Detection Yes
Backlight Yes
Alarm Audible + Visual
Power Supply 1.5V AA (2)
Dimensions 9.5" x 2.9" x 2.2" (240 x 74 x 55 mm)
Weight 1.05lbs (476g)
Warranty 3-year limited warranty 2-year sensor warranty
Cliquer ici pour toutes les spécifications du TPI 775

What's Included with the TPI 775

  • TPI 775 Combination Carbon Monoxide & Combustion Gas Leak Detector
  • Soft Carrying Case
  • Instructional Manual

TPI 775 Combination Carbon Monoxide & Combustion Gas Leak Detector


This video introduces and gives an overview of the unique features of this combination carbon monoxide & combustion gas leak detector.

Poser une question sur le TPI 775 Combination Carbon Monoxide & Combustion Gas Leak Detector

TPI 775 Offers

This combination of instruments is the first of its kind. All packaged into one easy to use instrument.

Features

  • One hand operation
  • Auto Zero
  • Display backlight
  • Both visual and audible alarm notification

Good To know

Don't expose yourself to Carbon Monoxide! Review the list below for the maximum allowable exposure limits and symptoms developed with CO inhalation.

  • 9ppm: The maximum allowable concentration for short term exposure in a living area according to ASHRAE
  • 50ppm: The Federal OSHA standard for continuous exposure in any eight hour period
  • 200ppm*: Maximum concentration allowable any time according to OSHA. Slight headaches, fatigue, dizziness, nausea after 2-3 hours
  • 400ppm*: Frontal headaches within 1-2 hours, life threatening after 3 hours. Maximum allowable limit in flue gas according to EPA and AGA
  • 800ppm*: Headache, dizziness, nausea, and convulsions with 45 minutes. Unconsciousness within 2 hours. Death within 2-3 minutes
  • 1600ppm*: Headache, dizziness, and nausea within 20 minutes. Death within 1 hour
  • 3200ppm*: Headache, dizziness, and nausea within 5-10 minutes. Death within 30 minutes
  • 6400ppm*: Headache, dizziness, and nausea within 1-2 minutes. Death within 10-15 minutes
  • 12800ppm*: Death within 1-3 minutes

* With exposure to this concentration and higher the effects can vary depending on size, age, sex, and health.

TPI 775 Specifications

Carbon Monoxide (CO) Measurement Range 0 ~ 2,000ppm
Accuracy ±5ppm or 5% of reading whichever is greater
Resolution 1ppm
Data Storage No
IR Printer Port No
Flue Probe No
Internal Pump No
Combustible Gas Leak Detection Yes
Backlight Yes
Alarm Audible + Visual
Power Supply 1.5V AA (2)
Dimensions 9.5" x 2.9" x 2.2" (240 x 74 x 55 mm)
Weight 1.05lbs (476g)
Warranty 3-year limited warranty 2-year sensor warranty
Cliquer ici pour toutes les spécifications du TPI 775

What's Included with the TPI 775

  • TPI 775 Combination Carbon Monoxide & Combustion Gas Leak Detector
  • Soft Carrying Case
  • Instructional Manual

TPI 775 Combination Carbon Monoxide & Combustion Gas Leak Detector


This video introduces and gives an overview of the unique features of this combination carbon monoxide & combustion gas leak detector.

Poser une question sur le TPI 775 Combination Carbon Monoxide & Combustion Gas Leak Detector

Plus de produits TPI