State of the art, easy to use analyzer designed not only to display and calculate the required readings from a flue but also to cover most of the other measurements associated with combustion. It provides ten selectable fuels and comes equipped with an infrared printer for hard copies of results.
State of the art, easy to use analyzer designed not only to display and calculate the required readings from a flue but also to cover most of the other measurements associated with combustion. It provides ten selectable fuels and comes equipped with an infrared printer for hard copies of results.
The combustion analyzer uses state of the art electrochemical sensors, which provide long-lasting, accurate, and reliable means for performing combustion tests.
Features
Prevent damage to your sensors by:
Applications
Gases | |
Oxygen | Range: 0 to 25% Resolution: 0.1% Accuracy: ±0.3% |
Carbon Monoxide | Range: 0 to 10,000 ppm Resolution: 1 ppm Accuracy: ±5 ppm or 5% |
Carbon Dioxide | Range: 0 to 25% Resolution: 0.1% Accuracy: Calculated |
CO/CO2 Ratio | Range: 0 to 0.999 Resolution: 0.001 Accuracy: Calculated |
Combustion Efficiency | Range: 0 to 10% Resolution: 0.1% Accuracy: Calculated |
Temperature Measurement | |
Input Type | K-Type thermocouple |
Range | -58 to 1832°F (-50 to 1000°C) |
Resolution | 1°F (1°C) |
Accuracy | ±(0.3% of rdg + 2°F) or ±(0.3% of rdg + 1°C) |
General Specifications | |
Operating Temperature Range | 14 to 122°F (-10 to 50°C) |
Battery/Battery Life | 3 x AA/>6 hours |
Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse |
Display | 3 line backlit LCD with annunciators |
Data Storage | 50 sets of readings |
Time and Date | 24-hour real time clock |
Dimensions | 7.8 x 3.5 x 2.4" |
Weight | 1.1 lbs |
Gases | |
Oxygen | Range: 0 to 25% Resolution: 0.1% Accuracy: ±0.3% |
Carbon Monoxide | Range: 0 to 10,000 ppm Resolution: 1 ppm Accuracy: ±5 ppm or 5% |
Carbon Dioxide | Range: 0 to 25% Resolution: 0.1% Accuracy: Calculated |
CO/CO2 Ratio | Range: 0 to 0.999 Resolution: 0.001 Accuracy: Calculated |
Combustion Efficiency | Range: 0 to 10% Resolution: 0.1% Accuracy: Calculated |
Temperature Measurement | |
Input Type | K-Type thermocouple |
Range | -58 to 1832°F (-50 to 1000°C) |
Resolution | 1°F (1°C) |
Accuracy | ±(0.3% of rdg + 2°F) or ±(0.3% of rdg + 1°C) |
General Specifications | |
Operating Temperature Range | 14 to 122°F (-10 to 50°C) |
Battery/Battery Life | 3 x AA/>6 hours |
Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse |
Display | 3 line backlit LCD with annunciators |
Data Storage | 50 sets of readings |
Time and Date | 24-hour real time clock |
Dimensions | 7.8 x 3.5 x 2.4" |
Weight | 1.1 lbs |