TPI 707 Carbon Monoxide Analyzer, 0 to 10,000 ppm

Modèle: 707 | No. de commande: 707/A | CUP: 637623007071

TPI 707 Carbon Monoxide Analyzer, 0 to 10,000 ppm-


Télécharger: datasheet manual

Plus de produits TPI

Demander à un expert

TPI 707 Carbon Monoxide Analyzer, 0 to 10,000 ppm

Modèle: 707 | No. de commande: 707/A | CUP: 637623007071

Portable and easy to use, this carbon monoxide analyzer is ideal for measuring CO levels in the flue and testing ambient CO levels in home and office spaces. In addition, this analyzer uses a state-of-the-art electrochemical sensor that provides long-lasting, accurate, and reliable means for performing tests.

Portable and easy to use, this carbon monoxide analyzer is ideal for measuring CO levels in the flue and testing ambient CO levels in home and office spaces. In addition, this analyzer uses a state-of-the-art electrochemical sensor that provides long-lasting, accurate, and reliable means for performing tests.

Prix spécial $541.34 CAD
Prix régulier $601.49 CAD
Disponibilité 1 en inventaire
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre 707

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre 707

TPI 707 Offers

Test flue gasses at home or office spaces for the presence and location of CO leaks with this state-of-the-art, easy-to-use analyzer designed to display carbon monoxide levels in and around appliances and work/living spaces. Additionally, with a protective rubber boot, this analyzer fits comfortably in your hand and operates with the push of a button.

Features

  • Clear and fast response with advance pump driven technology
  • Peak Hold to capture peak CO reading
  • Instrument recycles and will not shut off if 10 ppm CO is present, increasing safety
  • Store button allows you to save up to eight readings and then print using the IR port and optional printer (sold separately)
  • 1 ppm sensitivity
  • Measures up to 10,000 ppm
  • Push-on fittings are fast and easy to use
  • Large easy to read backlit display
  • Uses a state-of-the-art electrochemical sensor*
  • Sensor technology provides the longest lasting, most accurate and reliable means for performing tests

*The sensor in your analyzer will need to be replaced periodically and calibration is recommended once every year. The analyzer will remind you when calibration is due by flashing "CAL DUE Err" for three seconds at start up if the date of calibration is one year or older.

The following guidelines will help prevent damage to your sensor:

  • Always use the mini pump filter when performing tests
  • Always periodically check and replace the mini pump filter as needed
  • Always make sure the in-line filter/water trap is installed properly
  • Always periodically check and replace the in-line filter as needed
  • Always remove water or condensation from the inside of the in-line filter/water trap assembly prior to performing tests
  • Always use the optional oil filter (sold separately) when performing tests on oil burning equipment
  • Never over saturate your sensors by performing tests on equipment with gas levels beyond the capability of the analyzer
  • Always keep the water trap/filter assembly clean and replace the filter as necessary

Don't expose yourself to carbon monoxide!

Review the list below for the maximum allowable exposure limits and symptoms developed with CO inhalation.

  • 9 ppm: The maximum allowable concentration for short term exposure in a living area according to ASHRAE
  • 50 ppm: The Federal OSHA standard for continuous exposure in any eight hour period
  • 200 ppm*: Maximum concentration allowable any time according to OSHA. Slight headaches, fatigue, dizziness, nausea after two to three hours
  • 400 ppm*: Frontal headaches within one to two hours, life threatening after three hours. Maximum allowable limit in flue gas according to EPA and AGA
  • 800 ppm*: Headache, dizziness, nausea, and convulsions with 45 minutes. Unconsciousness within two hours. Death within two to three minutes
  • 1600 ppm*: Headache, dizziness, and nausea within 20 minutes. Death within one hour
  • 3200 ppm*: Headache, dizziness, and nausea within 5 to 10 minutes. Death within 30 minutes
  • 6400 ppm*: Headache, dizziness, and nausea within one to two minutes. Death within 10 to 15 minutes
  • 12,800 ppm*: Death within one to three minutes

*With exposure to this concentration and higher the effects can vary depending on size, age, sex, and health.

Applications

  • Ambient CO safety checks
  • Checking flue gases at home or office spaces for the presence and location of carbon monoxide
  • HVAC/R
  • Gas fireplace installation
  • Gas utility
  • Chemical plants
  • Propane companies
  • Fire departments
  • School and municipalities
  • Home inspection

TPI 707 Specifications

Range 0 to 10,000 ppm
Accuracy ±5 ppm or 5% of reading, whichever is greater
Resolution 1 ppm
Response Time 90% of reading <60 seconds
Warm-Up Approximately 20 seconds
Duty Cycle 30 minutes
Sensor Electrochemical
Flue Temperature Probe Construction: Straight grip with stainless steel shaft
Hose length: Approximately 5' (1.5 m)
Insertion length: 7.87" (200 mm)
Maximum temperature: 1292°F (700°C) for 5 minutes
Display Backlit LCD
Data Storage 50 sets of readings
Time and Date 24-hour real-time clock
Certifications RoHS compliant, cULus listed, CE
Operating Temperature Range 14 to 122°F (-10 to 50°C)
Battery Type: 3 x 1.5 V AA alkaline batteries
Life: >6 hours
Dimensions 3.75 x 8 x 3" (95 x 203 x 76 mm)
Weight 1.1 lbs (500 g)
Cliquer ici pour toutes les spécifications du TPI 707

What's included with the TPI 707

  • Carbon Monoxide Analyzer
  • Flue Sampling Probe with In-Line Filter Assembly Installed
  • Mini Pump Protection Filter Assembly and Spare Filters
  • Exhaust Spigot
  • Soft Carrying Case with Shoulder Strap
  • Rubber Boot
  • Instruction Manual
  • Three-Year Limited Warranty

TPI 707 Carbon Monoxide Analyzer: Overview


This video will serve as an overview of the carbon monoxide analyzer's key features. Additionally, this tool measures CO levels in the flue and test ambient CO levels in a home and office spaces.

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le TPI 707 Carbon Monoxide Analyzer, 0 to 10,000 ppm.

TPI A762F Filtres à particules de rechange pour pièges à eau TPI A762 et A796, pack de 5 A762F
Utilisez l'un de ces filtres dans votre purgeur d'eau compatible. Le filtre aide à piéger les particules avant qu'elles n'atteignent l'analyseur.




TPI A794W Filtre à eau pour TPI A794, A795 et A796 Pièges à eau A794W
Utilisez ce filtre à eau dans votre purgeur d'eau compatible. Le filtre est conçu pour empêcher l'eau de s'échapper du purgeur.




TPI A772 In-Line Sulfur Filter for TPI Combustion Analyzers A772
Install this filter on the flue probe of your device. The filter is designed for use with select TPI combustion analyzers.




Poser une question sur le TPI 707 Carbon Monoxide Analyzer, 0 to 10,000 ppm

TPI 707 Offers

Test flue gasses at home or office spaces for the presence and location of CO leaks with this state-of-the-art, easy-to-use analyzer designed to display carbon monoxide levels in and around appliances and work/living spaces. Additionally, with a protective rubber boot, this analyzer fits comfortably in your hand and operates with the push of a button.

Features

  • Clear and fast response with advance pump driven technology
  • Peak Hold to capture peak CO reading
  • Instrument recycles and will not shut off if 10 ppm CO is present, increasing safety
  • Store button allows you to save up to eight readings and then print using the IR port and optional printer (sold separately)
  • 1 ppm sensitivity
  • Measures up to 10,000 ppm
  • Push-on fittings are fast and easy to use
  • Large easy to read backlit display
  • Uses a state-of-the-art electrochemical sensor*
  • Sensor technology provides the longest lasting, most accurate and reliable means for performing tests

*The sensor in your analyzer will need to be replaced periodically and calibration is recommended once every year. The analyzer will remind you when calibration is due by flashing "CAL DUE Err" for three seconds at start up if the date of calibration is one year or older.

The following guidelines will help prevent damage to your sensor:

  • Always use the mini pump filter when performing tests
  • Always periodically check and replace the mini pump filter as needed
  • Always make sure the in-line filter/water trap is installed properly
  • Always periodically check and replace the in-line filter as needed
  • Always remove water or condensation from the inside of the in-line filter/water trap assembly prior to performing tests
  • Always use the optional oil filter (sold separately) when performing tests on oil burning equipment
  • Never over saturate your sensors by performing tests on equipment with gas levels beyond the capability of the analyzer
  • Always keep the water trap/filter assembly clean and replace the filter as necessary

Don't expose yourself to carbon monoxide!

Review the list below for the maximum allowable exposure limits and symptoms developed with CO inhalation.

  • 9 ppm: The maximum allowable concentration for short term exposure in a living area according to ASHRAE
  • 50 ppm: The Federal OSHA standard for continuous exposure in any eight hour period
  • 200 ppm*: Maximum concentration allowable any time according to OSHA. Slight headaches, fatigue, dizziness, nausea after two to three hours
  • 400 ppm*: Frontal headaches within one to two hours, life threatening after three hours. Maximum allowable limit in flue gas according to EPA and AGA
  • 800 ppm*: Headache, dizziness, nausea, and convulsions with 45 minutes. Unconsciousness within two hours. Death within two to three minutes
  • 1600 ppm*: Headache, dizziness, and nausea within 20 minutes. Death within one hour
  • 3200 ppm*: Headache, dizziness, and nausea within 5 to 10 minutes. Death within 30 minutes
  • 6400 ppm*: Headache, dizziness, and nausea within one to two minutes. Death within 10 to 15 minutes
  • 12,800 ppm*: Death within one to three minutes

*With exposure to this concentration and higher the effects can vary depending on size, age, sex, and health.

Applications

  • Ambient CO safety checks
  • Checking flue gases at home or office spaces for the presence and location of carbon monoxide
  • HVAC/R
  • Gas fireplace installation
  • Gas utility
  • Chemical plants
  • Propane companies
  • Fire departments
  • School and municipalities
  • Home inspection

TPI 707 Specifications

Range 0 to 10,000 ppm
Accuracy ±5 ppm or 5% of reading, whichever is greater
Resolution 1 ppm
Response Time 90% of reading <60 seconds
Warm-Up Approximately 20 seconds
Duty Cycle 30 minutes
Sensor Electrochemical
Flue Temperature Probe Construction: Straight grip with stainless steel shaft
Hose length: Approximately 5' (1.5 m)
Insertion length: 7.87" (200 mm)
Maximum temperature: 1292°F (700°C) for 5 minutes
Display Backlit LCD
Data Storage 50 sets of readings
Time and Date 24-hour real-time clock
Certifications RoHS compliant, cULus listed, CE
Operating Temperature Range 14 to 122°F (-10 to 50°C)
Battery Type: 3 x 1.5 V AA alkaline batteries
Life: >6 hours
Dimensions 3.75 x 8 x 3" (95 x 203 x 76 mm)
Weight 1.1 lbs (500 g)
Cliquer ici pour toutes les spécifications du TPI 707

What's included with the TPI 707

  • Carbon Monoxide Analyzer
  • Flue Sampling Probe with In-Line Filter Assembly Installed
  • Mini Pump Protection Filter Assembly and Spare Filters
  • Exhaust Spigot
  • Soft Carrying Case with Shoulder Strap
  • Rubber Boot
  • Instruction Manual
  • Three-Year Limited Warranty

TPI 707 Carbon Monoxide Analyzer: Overview


This video will serve as an overview of the carbon monoxide analyzer's key features. Additionally, this tool measures CO levels in the flue and test ambient CO levels in a home and office spaces.

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le TPI 707 Carbon Monoxide Analyzer, 0 to 10,000 ppm.

TPI A762F Filtres à particules de rechange pour pièges à eau TPI A762 et A796, pack de 5 A762F
Utilisez l'un de ces filtres dans votre purgeur d'eau compatible. Le filtre aide à piéger les particules avant qu'elles n'atteignent l'analyseur.




TPI A794W Filtre à eau pour TPI A794, A795 et A796 Pièges à eau A794W
Utilisez ce filtre à eau dans votre purgeur d'eau compatible. Le filtre est conçu pour empêcher l'eau de s'échapper du purgeur.




TPI A772 In-Line Sulfur Filter for TPI Combustion Analyzers A772
Install this filter on the flue probe of your device. The filter is designed for use with select TPI combustion analyzers.




Poser une question sur le TPI 707 Carbon Monoxide Analyzer, 0 to 10,000 ppm

Plus de produits TPI