Caractéristiques
Output Wavelength | 1310 and 1550 nm Laser |
Output power | 0 dBm ±1 dB (at 9/125 μm, adjustable over 3 dB in 0.1 dB steps) |
Short Term Stability | For 15 minutes, typical ±2°C, after warm up, at ORL < -25 dB:
|
Stability Over Temperature | 0.6 dB (typical) |
Wavelength Initial Tolerance | 20 nm (at 25°C) |
Spectrum width (FWHM) | 3 nm (typical) |
Wavelength drift | 0.4 nm per °C (typical) |
Reconnection Repeatability at 95% Confidence | 0.1 dB |
Calibration Validity ISO/IEC 17025 | 3 Years |
Modulation | 270 Hz 1 kHz 2 kHz ±2% |
Multi-fiber ID | 12 fibers |
Autotest | Compatible with KI Autotest power meter port and matching λ |
Power | 2 x AAA (LR-03) Alkaline |
Battery Life | Laser/LED source: 40/35 hours (typical) in Autotest |
Auto-off | Selectable |
Case | Polycarbonate with captive dust cap 2.5 m drop tested |
Temperature | Operating temperature: 5 to 131°F (-15 to 55°C) Storage temperature: -13 to 158°F (-25 to 70°C) |
Relative Humidity | 0 to 95% |
Warranty | 3 years |
Dimensions | 4.9 x 3.2 x 1" (124 x 81 x 25 mm) |
Weight | 0.33 lbs (0.15 kg) |
Shipping Weight | 0.66 lbs (0.3 kg) |
Output Wavelength | 1310 and 1550 nm Laser |
Output power | 0 dBm ±1 dB (at 9/125 μm, adjustable over 3 dB in 0.1 dB steps) |
Short Term Stability | For 15 minutes, typical ±2°C, after warm up, at ORL < -25 dB:
|
Stability Over Temperature | 0.6 dB (typical) |
Wavelength Initial Tolerance | 20 nm (at 25°C) |
Spectrum width (FWHM) | 3 nm (typical) |
Wavelength drift | 0.4 nm per °C (typical) |
Reconnection Repeatability at 95% Confidence | 0.1 dB |
Calibration Validity ISO/IEC 17025 | 3 Years |
Modulation | 270 Hz 1 kHz 2 kHz ±2% |
Multi-fiber ID | 12 fibers |
Autotest | Compatible with KI Autotest power meter port and matching λ |
Power | 2 x AAA (LR-03) Alkaline |
Battery Life | Laser/LED source: 40/35 hours (typical) in Autotest |
Auto-off | Selectable |
Case | Polycarbonate with captive dust cap 2.5 m drop tested |
Temperature | Operating temperature: 5 to 131°F (-15 to 55°C) Storage temperature: -13 to 158°F (-25 to 70°C) |
Relative Humidity | 0 to 95% |
Warranty | 3 years |
Dimensions | 4.9 x 3.2 x 1" (124 x 81 x 25 mm) |
Weight | 0.33 lbs (0.15 kg) |
Shipping Weight | 0.66 lbs (0.3 kg) |