Tempo T9600A-H3B Pocket Optical Power Meter, High Power for fiber optic systems up to +24 dBm

Modèle: T9600A-H3B | CUP: 810025419127

Tempo T9600A-H3B Pocket Optical Power Meter, High Power for fiber optic systems up to +24 dBm

Modèle: T9600A-H3B | CUP: 810025419127

A simple and reliable optical power meter for testing power and loss on high-power fiber optic systems up to +24 dBm. It provides high accuracy and simplicity of use. An advanced neutral density filter design offers improved accuracy for this type of instrument, and the use of an InGaAs detector provides better accuracy and response flatness for DWDM systems up to 1650 nm.

A simple and reliable optical power meter for testing power and loss on high-power fiber optic systems up to +24 dBm. It provides high accuracy and simplicity of use. An advanced neutral density filter design offers improved accuracy for this type of instrument, and the use of an InGaAs detector provides better accuracy and response flatness for DWDM systems up to 1650 nm.

Prix spécial $1135.80 CAD
Prix régulier $1262.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Tempo Communications T9600A-H3B offre

Caractéristiques

  • 9 calibration λ, ±2% accuracy, ISO/IEC 17025 traceable
  • Small size, easy to use, rugged and reliable
  • dBm, dB and linear, 0.01 dB resolution
  • Display hold and maximum/minimum recording
  • Tone detector with Multi-Fiber ID
  • Easy to use TamperLock mode
  • Interchangeable connectors
  • Full QA reports

Spécifications pour le Tempo Communications T9600A-H3B

Detector Type InGaAs
Response Wavelength 600 and 1700 nm
Calibration Wavelengths 850, 1300, 1310, 1390, 1490, 1550, 1577, 1610, 1625 nm
Power Range 24 to -40 dBm
Mid-range Linearity 0.04 dB (typical)
Total Uncertainty 0.3 dB (maximum)
Wavelength Sensitivity (± 30 nm) 0.03 dB (typical)
ID Tone Detection Sensitivity Up -30 dBm
Calibration Validity ISO/IEC 17025 3 years
Accuracy ±2%
Resolution 0.01 dB
Polarization Sensitivity <0.05 dB (typical)
Tone Detection 200 to 2500 Hz ±2%
Power 2 x AAA (LR-03) Alkaline
Battery Life 300 hours
Auto-off Selectable
Temperature Operating temperature: 5 to 131°F (-15 to 55°C)
Storage temperature: -13 to 158°F (-25 to 70°C)
Relative Humidity 0 to 95%
Warranty 3 years
Dimensions 4.9 x 3.2 x 1" (124 x 81 x 25 mm)
Weight 0.33 lbs (0.15 kg)
Shipping Weight 1.1 lbs (0.5 kg)

Le Tempo Communications T9600A-H3B comprend

  • Tempo T9600A-H3B Pocket Optical Power Meter, High Power for fiber optic systems up to +24 dBm
  • Three-Years Warranty

Poser une question sur le Tempo T9600A-H3B Pocket Optical Power Meter, High Power for fiber optic systems up to +24 dBm

Tempo Communications T9600A-H3B offre

Caractéristiques

  • 9 calibration λ, ±2% accuracy, ISO/IEC 17025 traceable
  • Small size, easy to use, rugged and reliable
  • dBm, dB and linear, 0.01 dB resolution
  • Display hold and maximum/minimum recording
  • Tone detector with Multi-Fiber ID
  • Easy to use TamperLock mode
  • Interchangeable connectors
  • Full QA reports

Spécifications pour le Tempo Communications T9600A-H3B

Detector Type InGaAs
Response Wavelength 600 and 1700 nm
Calibration Wavelengths 850, 1300, 1310, 1390, 1490, 1550, 1577, 1610, 1625 nm
Power Range 24 to -40 dBm
Mid-range Linearity 0.04 dB (typical)
Total Uncertainty 0.3 dB (maximum)
Wavelength Sensitivity (± 30 nm) 0.03 dB (typical)
ID Tone Detection Sensitivity Up -30 dBm
Calibration Validity ISO/IEC 17025 3 years
Accuracy ±2%
Resolution 0.01 dB
Polarization Sensitivity <0.05 dB (typical)
Tone Detection 200 to 2500 Hz ±2%
Power 2 x AAA (LR-03) Alkaline
Battery Life 300 hours
Auto-off Selectable
Temperature Operating temperature: 5 to 131°F (-15 to 55°C)
Storage temperature: -13 to 158°F (-25 to 70°C)
Relative Humidity 0 to 95%
Warranty 3 years
Dimensions 4.9 x 3.2 x 1" (124 x 81 x 25 mm)
Weight 0.33 lbs (0.15 kg)
Shipping Weight 1.1 lbs (0.5 kg)

Le Tempo Communications T9600A-H3B comprend

  • Tempo T9600A-H3B Pocket Optical Power Meter, High Power for fiber optic systems up to +24 dBm
  • Three-Years Warranty

Poser une question sur le Tempo T9600A-H3B Pocket Optical Power Meter, High Power for fiber optic systems up to +24 dBm

Plus de produits Tempo Communications