This is a handheld Optical Loss Test Set (OLTS) that integrates multimode LED sources 850 and 1300 nm with singlemode lasers 1310 and 1550 nm and an InGaAs power meter. Designed for both multimode and singlemode testing, it delivers accurate Tier 1 certification, optical loss, and power measurement. Compact, rugged, and easy to use, it is ideal for telecom, enterprise, and broadband networks.
This is a handheld Optical Loss Test Set (OLTS) that integrates multimode LED sources 850 and 1300 nm with singlemode lasers 1310 and 1550 nm and an InGaAs power meter. Designed for both multimode and singlemode testing, it delivers accurate Tier 1 certification, optical loss, and power measurement. Compact, rugged, and easy to use, it is ideal for telecom, enterprise, and broadband networks.
Caractéristiques
Detector Type | InGaAs |
Response Wavelength | 600 to 1700 nm |
Calibration Wavelengths | 820, 850, 980, 1270, and 1650 nm (25+ λ) |
Power Range | +10 to -70 dBm (InGaAs) |
Tone and Autotest Sensitivity | -50 dBm |
Midrange Linearity | 0.04 dB (typical) |
Calibration Accuracy | ±1% (0.06 dB) |
Polarization Sensitivity | <0.05 dB (typical, APC) |
Total Uncertainty | 0.3 dB |
Source Wavelengths | 850 and 1300 nm LED 1310 and 1550 nm laser |
Source Output Power | -3 dBm typical (laser) -35 dBm typical (LED) |
Source Stability | 0.04 dB (laser) 0.01 dB (LED) over 15 minutes |
Modulation | 270 Hz 1 kHz 2 kHz ±2% 12 Multi-Fiber ID tones |
VisiTester Option | Not included in this model |
Memory | 1000 4-λ tests with timestamp Unlimited via USB |
Display | 2.9 x 2.2" (74 x 55 mm) high contrast LCD |
Temperature | Operating: 5 to 131°F (-15 to 55°C) Storage: -13 to 158°F (-25 to 70°C) Humidity: 0 to 95% RH |
Warranty | 3 years |
Dimensions | 7.5 x 4.1 x 1.4" (190 x 105 x 35 mm) |
Weight | 0.93 lbs (420 g) |
Detector Type | InGaAs |
Response Wavelength | 600 to 1700 nm |
Calibration Wavelengths | 820, 850, 980, 1270, and 1650 nm (25+ λ) |
Power Range | +10 to -70 dBm (InGaAs) |
Tone and Autotest Sensitivity | -50 dBm |
Midrange Linearity | 0.04 dB (typical) |
Calibration Accuracy | ±1% (0.06 dB) |
Polarization Sensitivity | <0.05 dB (typical, APC) |
Total Uncertainty | 0.3 dB |
Source Wavelengths | 850 and 1300 nm LED 1310 and 1550 nm laser |
Source Output Power | -3 dBm typical (laser) -35 dBm typical (LED) |
Source Stability | 0.04 dB (laser) 0.01 dB (LED) over 15 minutes |
Modulation | 270 Hz 1 kHz 2 kHz ±2% 12 Multi-Fiber ID tones |
VisiTester Option | Not included in this model |
Memory | 1000 4-λ tests with timestamp Unlimited via USB |
Display | 2.9 x 2.2" (74 x 55 mm) high contrast LCD |
Temperature | Operating: 5 to 131°F (-15 to 55°C) Storage: -13 to 158°F (-25 to 70°C) Humidity: 0 to 95% RH |
Warranty | 3 years |
Dimensions | 7.5 x 4.1 x 1.4" (190 x 105 x 35 mm) |
Weight | 0.93 lbs (420 g) |