This Rogowski probe has low-frequency performance and a flexible coil. Because it's so flexible, you can use it without modification to the circuit under test.

This Rogowski probe has low-frequency performance and a flexible coil. Because it's so flexible, you can use it without modification to the circuit under test.

Prix spécial $2695.00 CAD
Prix régulier $2750.00 CAD
Disponibilité 10 à 11 semaines
Quantité

Teledyne LeCroy T3RC3000-LF offre

Get the bandwidth and performance you need when you use the Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe. Between the flexible coil and the low insertion load, it helps testing flow smoothly. You can plug into the wall to work at the bench, or insert the batteries and use it out in the field.

Caractéristiques

  • Compatible with most oscilloscopes with a BNC input connector and a 1 MΩ input impedance
  • Wide operating temperature ideal for a variety of applications
  • Extended low-frequency performance
  • High level of peak insulation
  • Flexible coil helps increase accuracy while remaining isolated
  • Doesn't require modifications to the DUT
  • Low insertion load of the circuit under test
  • Use with either batteries or the plug-in power adapter
  • Calibrated to ±0.2% reading with conductor central in the coil loop

Applications

  • Component design and development
  • System-level development
  • Power converter design and development
  • Long-term system monitoring

Spécifications pour le Teledyne LeCroy T3RC3000-LF

Peak Current 3,000 A
Bandwidth 0.11 Hz to 6.5 MHz
Sensitivity 2 mV/A
Max Noise 2.5 mV rms
Droop 0.1%/ms
LF (-3 dB) Bandwidth 0.11 Hz
HF (-3 dB) Bandwidth 6.5 MHz
Peak di/dt 11 kA/us
Attenuation Ratio 500
Cable Length 13' (4 m)
Coil Circumference 11.8" (300 mm)
Coil Thickness 0.33" (8.5 mm)
Peak Coil Insulation Voltage 10 kV
Accuracy ±1% (variation with conductor position in the coil), 0.05% of reading (linearity of current magnitude)
Temperature Coil and cable: -4 to 212°F (-20 to 100°C); integrator: 32 to 104°F (0 to 40°C)
Manufacturer Warranty 1-year limited

Le Teledyne LeCroy T3RC3000-LF comprend

  • Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe, 3,000 A, 0.11 Hz to 6.5 MHz

Poser une question sur le Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe, 3,000 A, 0.11 Hz to 6.5 MHz

Teledyne LeCroy T3RC3000-LF offre

Get the bandwidth and performance you need when you use the Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe. Between the flexible coil and the low insertion load, it helps testing flow smoothly. You can plug into the wall to work at the bench, or insert the batteries and use it out in the field.

Caractéristiques

  • Compatible with most oscilloscopes with a BNC input connector and a 1 MΩ input impedance
  • Wide operating temperature ideal for a variety of applications
  • Extended low-frequency performance
  • High level of peak insulation
  • Flexible coil helps increase accuracy while remaining isolated
  • Doesn't require modifications to the DUT
  • Low insertion load of the circuit under test
  • Use with either batteries or the plug-in power adapter
  • Calibrated to ±0.2% reading with conductor central in the coil loop

Applications

  • Component design and development
  • System-level development
  • Power converter design and development
  • Long-term system monitoring

Spécifications pour le Teledyne LeCroy T3RC3000-LF

Peak Current 3,000 A
Bandwidth 0.11 Hz to 6.5 MHz
Sensitivity 2 mV/A
Max Noise 2.5 mV rms
Droop 0.1%/ms
LF (-3 dB) Bandwidth 0.11 Hz
HF (-3 dB) Bandwidth 6.5 MHz
Peak di/dt 11 kA/us
Attenuation Ratio 500
Cable Length 13' (4 m)
Coil Circumference 11.8" (300 mm)
Coil Thickness 0.33" (8.5 mm)
Peak Coil Insulation Voltage 10 kV
Accuracy ±1% (variation with conductor position in the coil), 0.05% of reading (linearity of current magnitude)
Temperature Coil and cable: -4 to 212°F (-20 to 100°C); integrator: 32 to 104°F (0 to 40°C)
Manufacturer Warranty 1-year limited