Teledyne LeCroy T3RC0600-HF Rogowski AC Current Probe, 600 A, 12 Hz to 30 MHz

Modèle: T3RC0600-HF

Teledyne LeCroy T3RC0600-HF Rogowski AC Current Probe, 600 A, 12 Hz to 30 MHz

Modèle: T3RC0600-HF

This Rogowski probe is equipped for extended high-frequency coverage. Use it for a range of general purpose applications.

This Rogowski probe is equipped for extended high-frequency coverage. Use it for a range of general purpose applications.

Prix spécial $2766.54 CAD
Prix régulier $2823.00 CAD
Disponibilité 10 à 11 semaines
Quantité

Teledyne LeCroy T3RC0600-HF Offers



With a wide operating temperature, the Teledyne LeCroy T3RC0600-HF Rogowski AC Current Probe works well in most general applications and environments. It features a flexible coil design and can be used without modification to the DUT. For your convenience, you can plug it into the wall or take it on the go with batteries.

Features

  • Compatible with most oscilloscopes with a BNC input connector and a 1 MΩ input impedance
  • Ideal for general purpose applications and wide temperature environments
  • Offers extended high-frequency coverage
  • Flexible coil makes it easy to access difficult areas while maintaining accuracy
  • Can be used without having to modify the DUT
  • Low loading of the circuit under test
  • Calibrated to ±0.2% reading with conductor central in the coil loop
  • Uses batteries and a plug-in power adapter to give you the flexibility you need
  • Applications Component Design and Development, Research and Development, System-Level Development, Power Converter Design and Development, Long-Term System Monitoring

Teledyne LeCroy T3RC0600-HF Specifications


Peak Current600 A
Bandwidth12 Hz to 30 MHz
Sensitivity10 mV/A
Max Noise1.7 mV rms
Droop11%/ms
LF (-3 dB) Bandwidth12 Hz
HF (-3 dB) Bandwidth30 MHz
Peak di/dt40 kA/us
Attenuation Ratio100
Cable Length3.28" (1 m)
Coil Circumference3.94" (100 mm)
Coil Thickness0.177" (4.5 mm)
Peak Coil Insulation Voltage5 kV
Accuracy±2% (variation with conductor position in the coil); 0.05% of reading (linearity of current magnitude)
TemperatureCoil and cable: -40 to 257°F (-40 to 125°C); integrator: 32 to 104°F (0 to 40°C)
Manufacturer Warranty1-year limited
Cliquer ici pour toutes les spécifications du Teledyne LeCroy T3RC0600-HF

Le Teledyne LeCroy T3RC0600-HF comprend

  • Teledyne LeCroy T3RC0600-HF Rogowski AC Current Probe, 600 A, 12 Hz to 30 MHz

Poser une question sur le Teledyne LeCroy T3RC0600-HF Rogowski AC Current Probe, 600 A, 12 Hz to 30 MHz

Teledyne LeCroy T3RC0600-HF Offers



With a wide operating temperature, the Teledyne LeCroy T3RC0600-HF Rogowski AC Current Probe works well in most general applications and environments. It features a flexible coil design and can be used without modification to the DUT. For your convenience, you can plug it into the wall or take it on the go with batteries.

Features

  • Compatible with most oscilloscopes with a BNC input connector and a 1 MΩ input impedance
  • Ideal for general purpose applications and wide temperature environments
  • Offers extended high-frequency coverage
  • Flexible coil makes it easy to access difficult areas while maintaining accuracy
  • Can be used without having to modify the DUT
  • Low loading of the circuit under test
  • Calibrated to ±0.2% reading with conductor central in the coil loop
  • Uses batteries and a plug-in power adapter to give you the flexibility you need
  • Applications Component Design and Development, Research and Development, System-Level Development, Power Converter Design and Development, Long-Term System Monitoring

Teledyne LeCroy T3RC0600-HF Specifications


Peak Current600 A
Bandwidth12 Hz to 30 MHz
Sensitivity10 mV/A
Max Noise1.7 mV rms
Droop11%/ms
LF (-3 dB) Bandwidth12 Hz
HF (-3 dB) Bandwidth30 MHz
Peak di/dt40 kA/us
Attenuation Ratio100
Cable Length3.28" (1 m)
Coil Circumference3.94" (100 mm)
Coil Thickness0.177" (4.5 mm)
Peak Coil Insulation Voltage5 kV
Accuracy±2% (variation with conductor position in the coil); 0.05% of reading (linearity of current magnitude)
TemperatureCoil and cable: -40 to 257°F (-40 to 125°C); integrator: 32 to 104°F (0 to 40°C)
Manufacturer Warranty1-year limited
Cliquer ici pour toutes les spécifications du Teledyne LeCroy T3RC0600-HF

Le Teledyne LeCroy T3RC0600-HF comprend

  • Teledyne LeCroy T3RC0600-HF Rogowski AC Current Probe, 600 A, 12 Hz to 30 MHz

Poser une question sur le Teledyne LeCroy T3RC0600-HF Rogowski AC Current Probe, 600 A, 12 Hz to 30 MHz

Plus de produits Teledyne LeCroy