03
jours
21
heures
51
mins

Promotion vendredi fou et cyberlundi - Épargnez 5% sur tout avec le code promo CYBER5
Promotion vendredi fou et cyberlundi - Épargnez 5% sur tout avec le code promo CYBER5

Teledyne LeCroy MS-500-36 250 MHz (500 MHz) Mixed Signal Oscilloscope Option

Modèle: MS-500-36

Teledyne LeCroy MS-500-36 250 MHz (500 MHz) Mixed Signal Oscilloscope Option

Modèle: MS-500-36

Designed to capture long records of the fastest digital signals the MS-500-36 has a maximum input frequency of 500 MHz and this product can be operated in 36 or 18 channel mode for higher performance.

Designed to capture long records of the fastest digital signals the MS-500-36 has a maximum input frequency of 500 MHz and this product can be operated in 36 or 18 channel mode for higher performance.

Prix spécial $14574.56 CAD
Prix régulier $14872.00 CAD
Disponibilité 15+ semaines
Quantité

Teledyne LeCroy MS-500-36 Offers

The MS-500-36 is ideally suited for embedded controller testing where there is a proliferation of analog signals coincident with digital signals.

Features

  • Trigger and decode serial data signals such as I2C, SPI, UART, RS-232, and LIN
  • Use cursors to read hexadecimal bus values or make manual timing measurements
  • Automatic measurement parameters like period, frequency and duty cycle work on digital lines just as they would on oscilloscope channels
  • Analog bandwidths from 200 MHz to 2 GHz with sampling rates up to 10 GS/s
  • Up to 50 Mpts/Ch digital memory provides very long capture times of all your digital signals, with sampling rates up to 2 GS/s
  • Long oscilloscope memory enables capturing long records of analog signals while maintaining high sample rate for fast edges
  • Complete analog/digital cross triggering
  • Sampling rate of 2 GS/s on digital lines

Teledyne LeCroy MS-500-36 Specifications

Maximum Input Frequency 250 MHz (500 MHz)
Sample Rate 1 GS/s (2 GS/s)
Acquisition Memory (Per Channel) 25 Mpts/Ch (50 Mpts/Ch)
Number of Digital Channels 36 (18)
Threshold Groupings D0-D8, D9-D17, D18-D25, D26-D35
Threshold Levels TTL, ECL, CMOS (2.5 V, 3.3 V, 5 V), PECL, LVDS or User Defined
Trigger Types Edge, Width, Pattern, Glitch, Interval, Dropout
Serial Data Triggers (Optional) I2C, SPI, UART, RS-232, LIN
Trigger Sources C1-C4, D0-D35, EXT
Dimensions 4.25 x 8.375 x 1.5" (10.8 x 21.3 x 3.8 cm)
Net Weight 1.7 lbs (0.775 kg)
Lead Set Length 16" (40.65 cm)
Cliquer ici pour toutes les spécifications du Teledyne LeCroy MS-500-36

Le Teledyne LeCroy MS-500-36 comprend

  • Teledyne LeCroy MS-500-36 250 MHz (500 MHz) Mixed Signal Oscilloscope Option

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Teledyne LeCroy MS-500-36 250 MHz (500 MHz) Mixed Signal Oscilloscope Option.

Teledyne LeCroy MSO-DLS-18 18 Channel Lead Set Replacement (D0-D17) MSO-DLS-18
16" 18 Channel Digital Lead Set.




Teledyne LeCroy MSO-DLS-36 18 Channel Lead Set (D18-D35) Enables 36 Channels on MS-500 MSO-DLS-36
16" 18 Channel Digital Lead Set. Enables 36 Channels on the MS-500 Mixed Signal Oscilloscope Option.




Poser une question sur le Teledyne LeCroy MS-500-36 250 MHz (500 MHz) Mixed Signal Oscilloscope Option

Teledyne LeCroy MS-500-36 Offers

The MS-500-36 is ideally suited for embedded controller testing where there is a proliferation of analog signals coincident with digital signals.

Features

  • Trigger and decode serial data signals such as I2C, SPI, UART, RS-232, and LIN
  • Use cursors to read hexadecimal bus values or make manual timing measurements
  • Automatic measurement parameters like period, frequency and duty cycle work on digital lines just as they would on oscilloscope channels
  • Analog bandwidths from 200 MHz to 2 GHz with sampling rates up to 10 GS/s
  • Up to 50 Mpts/Ch digital memory provides very long capture times of all your digital signals, with sampling rates up to 2 GS/s
  • Long oscilloscope memory enables capturing long records of analog signals while maintaining high sample rate for fast edges
  • Complete analog/digital cross triggering
  • Sampling rate of 2 GS/s on digital lines

Teledyne LeCroy MS-500-36 Specifications

Maximum Input Frequency 250 MHz (500 MHz)
Sample Rate 1 GS/s (2 GS/s)
Acquisition Memory (Per Channel) 25 Mpts/Ch (50 Mpts/Ch)
Number of Digital Channels 36 (18)
Threshold Groupings D0-D8, D9-D17, D18-D25, D26-D35
Threshold Levels TTL, ECL, CMOS (2.5 V, 3.3 V, 5 V), PECL, LVDS or User Defined
Trigger Types Edge, Width, Pattern, Glitch, Interval, Dropout
Serial Data Triggers (Optional) I2C, SPI, UART, RS-232, LIN
Trigger Sources C1-C4, D0-D35, EXT
Dimensions 4.25 x 8.375 x 1.5" (10.8 x 21.3 x 3.8 cm)
Net Weight 1.7 lbs (0.775 kg)
Lead Set Length 16" (40.65 cm)
Cliquer ici pour toutes les spécifications du Teledyne LeCroy MS-500-36

Le Teledyne LeCroy MS-500-36 comprend

  • Teledyne LeCroy MS-500-36 250 MHz (500 MHz) Mixed Signal Oscilloscope Option

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Teledyne LeCroy MS-500-36 250 MHz (500 MHz) Mixed Signal Oscilloscope Option.

Teledyne LeCroy MSO-DLS-18 18 Channel Lead Set Replacement (D0-D17) MSO-DLS-18
16" 18 Channel Digital Lead Set.




Teledyne LeCroy MSO-DLS-36 18 Channel Lead Set (D18-D35) Enables 36 Channels on MS-500 MSO-DLS-36
16" 18 Channel Digital Lead Set. Enables 36 Channels on the MS-500 Mixed Signal Oscilloscope Option.




Poser une question sur le Teledyne LeCroy MS-500-36 250 MHz (500 MHz) Mixed Signal Oscilloscope Option

Plus de produits Teledyne LeCroy