The AP031 is a low cost, battery operated active differential probe intended for measuring higher voltages. The differential techniques employed permit measurements to be taken at two points in a circuit without reference to the ground, allowing the oscilloscope to be safely grounded without the use of opto-isolators or isolating transformers.
The AP031 is a low cost, battery operated active differential probe intended for measuring higher voltages. The differential techniques employed permit measurements to be taken at two points in a circuit without reference to the ground, allowing the oscilloscope to be safely grounded without the use of opto-isolators or isolating transformers.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:
Visitez notre catégorie Sondes de tension pour trouver des produits similaires.
Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:
This probe is specifically designed for situations where:
| Bandwidth | 25 MHz |
| Rise Time | 14 ns |
| Attenuation | 1:10/1:100 |
| Attenuation Accuracy | ±2 % |
| Input Resistance | 4 Mω |
| Input Capacitance | 5.5 pF each side to ground |
| Input Configuration | Differential |
| Input Voltage | Maximum Differential 1:100 Range: ±700 V (DC + AC pk) and 700 V rms Maximum Differential 1:10 Range: ±70 V (DC + AC pk) and 70 V rms Maximum Common Mode: ±700 V (DC + AC pk) and 700 V rms Maximum Absolute: ±1400 V ( DC + AC pk) and 1000 V rms |
| CMRR | 50 Hz to 80 dB; 20 kHz to 60 dB |
| Typical Output Offset | <±5 mV |
| Typical Output Noise | 0.7 mV rms typical |
| Maximum Input Voltage | 1000 V rms (1400 V DC + peak AC) |
| Installation (Overvoltage) | Category III |
| Pollution Degree | 2 |
| Cable Length | 1.3 m |
| Weight (probe only) | 42 g |
| Bandwidth | 25 MHz |
| Rise Time | 14 ns |
| Attenuation | 1:10/1:100 |
| Attenuation Accuracy | ±2 % |
| Input Resistance | 4 Mω |
| Input Capacitance | 5.5 pF each side to ground |
| Input Configuration | Differential |
| Input Voltage | Maximum Differential 1:100 Range: ±700 V (DC + AC pk) and 700 V rms Maximum Differential 1:10 Range: ±70 V (DC + AC pk) and 70 V rms Maximum Common Mode: ±700 V (DC + AC pk) and 700 V rms Maximum Absolute: ±1400 V ( DC + AC pk) and 1000 V rms |
| CMRR | 50 Hz to 80 dB; 20 kHz to 60 dB |
| Typical Output Offset | <±5 mV |
| Typical Output Noise | 0.7 mV rms typical |
| Maximum Input Voltage | 1000 V rms (1400 V DC + peak AC) |
| Installation (Overvoltage) | Category III |
| Pollution Degree | 2 |
| Cable Length | 1.3 m |
| Weight (probe only) | 42 g |