The PM-DC series panel meters offer flexibility with its programmable scaling and AC or DC power options. This panel meter has DC signal input with jumper selectable range, low voltage power, contact relay output and RS-485 communication protocol.

The PM-DC series panel meters offer flexibility with its programmable scaling and AC or DC power options. This panel meter has DC signal input with jumper selectable range, low voltage power, contact relay output and RS-485 communication protocol.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:

Visitez notre catégorie Compteurs de panneau de traitement pour trouver des produits similaires.

Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:


SHIMPO PM-DCA-1R0C2 offre

The PM-DC 1/8 DIN Process Meters offers versatility with a numerous selections of input and output configurations. It has a Jumper-Selectable DC Signal Input Ranges ideal for process automation applications. The programmable scaling feature of this panel meter allows customization to display the readings of the desired engineering units according to the application needs. Universal AC or DC power options enable flexibility with usage in various power situations.

Caractéristiques

  • Bright, red 5 digit LED display scalable to ±99,999 with adjustable decimal point
  • Universal power range of 85 to 264 V AC / 90 to 300 V DC or 10 to 48 V DC / 12 to 32 V AC power eliminates need to purchase country specific models
  • Programmable scaling provides flexibility to set up and monitor virtually any process in the desired engineering units
  • Accuracy of ±0.01% of full scale ±2 counts (LSD)
  • Isolated transducer power output of 5, 10 or 24 V DC, eliminates need for an additional power supply reducing installation costs
  • Digital filtering is menu-selectable for electrically noisy environments
  • Peak and valley values are automatically captured and may be displayed via a pushbutton, control signal input, or be transmitted as serial data if a communication option was ordered
  • High read rates at up to 60 or 50 conversions per second
  • When panel mounted, NEMA 4X (IP65) front cover protection keeps fluids out; enables installation in environments exposed to wash-downs

Applications

The PM-DC Process Meters with DC signal inputs are ideal for indicating current or voltage signals from process sensors, transmitters and transducers in applications involving temperature, pressure, level, flow rate, speed, humidity, level, distance and a myriad more. The PM-DC’s are also commonly used to detect DC power output from solar cells, power supplies, batteries as well as current consumption of DC powered motors and similar devices.

Spécifications pour le SHIMPO PM-DCA-1R0C2

Input Signal Ranges (Jumper Selectable) ±2.0000 mA, ±20.000 mA, ±200.00 mA, ±5.000 A
Input Power 12 to 34 V AC or 10 to 48 V DC
Relay Output Relay Output Two 8 A Form C contact relays
Analog Output
Display Range -99999 to 99999
Scaling Function 5 digits with decimal point adjustment
Accuracy @ 77°F (25°C) ±0.01% of FS ±2 Counts; 5A Range ±10 mA; 300 V & 600 V = ±0.4 V
Display Update Time 3.5/s at 60 Hz, 3/s at 50 Hz
Communication RS-485
Power Requirement 10 to 48 V DC / 12 to 34 V AC
Dimensions 1.89 x 3.78 x 4" (48 x 96 x 102 mm) 1/8 DIN. Panel Cutout: 1.77 x 3.62" (45 x 92 mm); Max. Panel Thickness: 0.18" (4.5 mm)

Le SHIMPO PM-DCA-1R0C2 comprend

  • Shimpo PM-DCA-1R0C2 DC AMP Panel Meter, contact relay output, RS-485

Poser une question sur le Shimpo PM-DCA-1R0C2 DC AMP Panel Meter, contact relay output, RS-485

SHIMPO PM-DCA-1R0C2 offre

The PM-DC 1/8 DIN Process Meters offers versatility with a numerous selections of input and output configurations. It has a Jumper-Selectable DC Signal Input Ranges ideal for process automation applications. The programmable scaling feature of this panel meter allows customization to display the readings of the desired engineering units according to the application needs. Universal AC or DC power options enable flexibility with usage in various power situations.

Caractéristiques

  • Bright, red 5 digit LED display scalable to ±99,999 with adjustable decimal point
  • Universal power range of 85 to 264 V AC / 90 to 300 V DC or 10 to 48 V DC / 12 to 32 V AC power eliminates need to purchase country specific models
  • Programmable scaling provides flexibility to set up and monitor virtually any process in the desired engineering units
  • Accuracy of ±0.01% of full scale ±2 counts (LSD)
  • Isolated transducer power output of 5, 10 or 24 V DC, eliminates need for an additional power supply reducing installation costs
  • Digital filtering is menu-selectable for electrically noisy environments
  • Peak and valley values are automatically captured and may be displayed via a pushbutton, control signal input, or be transmitted as serial data if a communication option was ordered
  • High read rates at up to 60 or 50 conversions per second
  • When panel mounted, NEMA 4X (IP65) front cover protection keeps fluids out; enables installation in environments exposed to wash-downs

Applications

The PM-DC Process Meters with DC signal inputs are ideal for indicating current or voltage signals from process sensors, transmitters and transducers in applications involving temperature, pressure, level, flow rate, speed, humidity, level, distance and a myriad more. The PM-DC’s are also commonly used to detect DC power output from solar cells, power supplies, batteries as well as current consumption of DC powered motors and similar devices.

Spécifications pour le SHIMPO PM-DCA-1R0C2

Input Signal Ranges (Jumper Selectable) ±2.0000 mA, ±20.000 mA, ±200.00 mA, ±5.000 A
Input Power 12 to 34 V AC or 10 to 48 V DC
Relay Output Relay Output Two 8 A Form C contact relays
Analog Output
Display Range -99999 to 99999
Scaling Function 5 digits with decimal point adjustment
Accuracy @ 77°F (25°C) ±0.01% of FS ±2 Counts; 5A Range ±10 mA; 300 V & 600 V = ±0.4 V
Display Update Time 3.5/s at 60 Hz, 3/s at 50 Hz
Communication RS-485
Power Requirement 10 to 48 V DC / 12 to 34 V AC
Dimensions 1.89 x 3.78 x 4" (48 x 96 x 102 mm) 1/8 DIN. Panel Cutout: 1.77 x 3.62" (45 x 92 mm); Max. Panel Thickness: 0.18" (4.5 mm)