This panel meter can be set to one of 4 input ranges from ±2.0000 mA with 0.1 µA resolution to ±5.000 A with 1 mA resolution. It comes standard with an isolated excitation output to power transducers, removing the need for an additional power supply. The PM-DCA-000C5 has USB communications.
This panel meter can be set to one of 4 input ranges from ±2.0000 mA with 0.1 µA resolution to ±5.000 A with 1 mA resolution. It comes standard with an isolated excitation output to power transducers, removing the need for an additional power supply. The PM-DCA-000C5 has USB communications.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:
Visitez notre catégorie Current Panel Meters pour trouver des produits similaires.
Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:
The PM-DCA-000C5 is ideal for indicating current or voltage signals in applications involving temperature, pressure, level, flow rate, speed, humidity, level, distance and many more. Used to detect DC power output from solar cells, power supplies, batteries as well as current consumption of DC powered motors and similar devices.
Caractéristiques
Applications
| Input Signal Ranges (Jumper Selectable) | ±2.0000 mA, ±20.000 mA, ±200.00 mA, ±5.000 A |
| Display Range | -99999 to 99999 |
| Scaling Function | 5 digits with decimal point adjustment |
| Accuracy @ 77°F (25°C) | ±0.01% of FS ±2 Counts; 5A Range ±10 mA; 300 V & 600 V = ±0.4 V |
| Display Update Time | 3.5/s at 60 Hz, 3/s at 50 Hz |
| Relay Output (Optional) | Mechanical Relays: 8 A @ 250 V AC or 24 V dc; SSR: 120 mA @ 140 V AC or 180 V dc |
| Analog Signal Output (Optional) | Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V |
| Communication: (Optional) | RS-232, RS-485, USB |
| Power Requirement | 85-264 V AC / 95-300 V DC; Optional 10-48 V DC / 12-34 V AC |
| Sensor Excitation (Isolated) | 5 Vdc ±5%, 100 mA; 10 V DC ±5%, 120 mA; or 24 V DC ±5%, 50 mA |
| Input Signal Ranges (Jumper Selectable) | ±2.0000 mA, ±20.000 mA, ±200.00 mA, ±5.000 A |
| Display Range | -99999 to 99999 |
| Scaling Function | 5 digits with decimal point adjustment |
| Accuracy @ 77°F (25°C) | ±0.01% of FS ±2 Counts; 5A Range ±10 mA; 300 V & 600 V = ±0.4 V |
| Display Update Time | 3.5/s at 60 Hz, 3/s at 50 Hz |
| Relay Output (Optional) | Mechanical Relays: 8 A @ 250 V AC or 24 V dc; SSR: 120 mA @ 140 V AC or 180 V dc |
| Analog Signal Output (Optional) | Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V |
| Communication: (Optional) | RS-232, RS-485, USB |
| Power Requirement | 85-264 V AC / 95-300 V DC; Optional 10-48 V DC / 12-34 V AC |
| Sensor Excitation (Isolated) | 5 Vdc ±5%, 100 mA; 10 V DC ±5%, 120 mA; or 24 V DC ±5%, 50 mA |