A three-phase DIN rail energy meter that supports Rogowski coil CTs with a built-in integrator and CT power supply, offering a 20 to 5000 A measurement range and Modbus communication in a 2-quadrant configuration.
A three-phase DIN rail energy meter that supports Rogowski coil CTs with a built-in integrator and CT power supply, offering a 20 to 5000 A measurement range and Modbus communication in a 2-quadrant configuration.
Caractéristiques
Applications
| Range | PowerLogic |
| Product or Component Type | Energy meter |
| Metering Type | Peak demand power PM, QM, SM Demand power P, Q, S Voltage U21, U32, U13, V1, V2, V3 Current I1, I2, I3, Iavg |
| Poles Description | 3P + N |
| Type Of Measurement | Active and reactive power total Active and reactive power per phase Apparent power total Apparent power per phase Power factor total Power factor per phase Peak demand power Current Voltage Frequency |
| Device Application | Sub billing Partial meter |
| Accuracy Class | Class 0.5S power IEC 62053-22 Class 0.5S energy IEC 62053-22 Class 0.5S power ANSI C12.20 Class 0.5S energy ANSI C12.20 |
| Measurement Accuracy | Power ± 0.5% Energy ± 0.5% |
| Input Type | Rogowski coil 50 to 5000 A |
| Rated Voltage | 90 to 347 V |
| Network Frequency | 50 Hz 60 Hz |
| Technology Type | Electronic |
| Display Type | Backlit LCD |
| Measurement Current | 20 to 5000 A |
| Display Digits | 5 |
| Information Displayed | Status and alert Communication with system Input/output status Error Tx activity Rx activity Instant power per usage |
| Tamperproof of Settings | Protected by access code |
| Communication Port Protocol | Modbus RTU 1200 to 38400 bps - 2-wire |
| Communication Port Support | Screw terminal block RS485 |
| Communication Service | Total cumulated energy Total cumulated active energy |
| Data Recording | Energy consumption logs |
| Demand Intervals | External synchronisation to communication Fixed or rolling block |
| Local Signalling | Red LED threshold reached Green flashing LED output signal |
| Number of Outputs | 1 alarm output 1 pulse |
| Rated Operational Voltage | 90 to 347 VAC 50/60 Hz between phase and neutral UL 156 to 600 V AC 50/60 Hz between phases UL 90 to 300 V AC 50/60 Hz between phase and neutral CE 125 to 300 V DC |
| Power Consumption in VA | 5 VA 347 VAC between phase and neutral) 5 VA 600 VAC between phases) |
| Power Consumption in W | 3 W 300 V |
| Ride-through Time | 100 ms 120 VAC |
| Mounting Mode | Clip-on By screws |
| Mounting Support | DIN rail |
| Standards | IEC 61010-1 CSA C22.2 No 14-05 UL 508 |
| Product Certifications | CE conforming to IEC 61010 CULus conforming to UL 508 |
| Relative Humidity | 0 to 95 % |
| Ambient Air Temperature for Operation | -22 to 158°F (-30 to 70°C) |
| Ambient Air Temperature for Storage | -40 to 185°F (-40 to 85°C) |
| Colour | Dark grey |
| 0.35" (9 mm) Pitches | 12 |
| Dimensions | 2.3 x 4.2 x 3.6" (59 x 107 x 91 mm) |
| Range | PowerLogic |
| Product or Component Type | Energy meter |
| Metering Type | Peak demand power PM, QM, SM Demand power P, Q, S Voltage U21, U32, U13, V1, V2, V3 Current I1, I2, I3, Iavg |
| Poles Description | 3P + N |
| Type Of Measurement | Active and reactive power total Active and reactive power per phase Apparent power total Apparent power per phase Power factor total Power factor per phase Peak demand power Current Voltage Frequency |
| Device Application | Sub billing Partial meter |
| Accuracy Class | Class 0.5S power IEC 62053-22 Class 0.5S energy IEC 62053-22 Class 0.5S power ANSI C12.20 Class 0.5S energy ANSI C12.20 |
| Measurement Accuracy | Power ± 0.5% Energy ± 0.5% |
| Input Type | Rogowski coil 50 to 5000 A |
| Rated Voltage | 90 to 347 V |
| Network Frequency | 50 Hz 60 Hz |
| Technology Type | Electronic |
| Display Type | Backlit LCD |
| Measurement Current | 20 to 5000 A |
| Display Digits | 5 |
| Information Displayed | Status and alert Communication with system Input/output status Error Tx activity Rx activity Instant power per usage |
| Tamperproof of Settings | Protected by access code |
| Communication Port Protocol | Modbus RTU 1200 to 38400 bps - 2-wire |
| Communication Port Support | Screw terminal block RS485 |
| Communication Service | Total cumulated energy Total cumulated active energy |
| Data Recording | Energy consumption logs |
| Demand Intervals | External synchronisation to communication Fixed or rolling block |
| Local Signalling | Red LED threshold reached Green flashing LED output signal |
| Number of Outputs | 1 alarm output 1 pulse |
| Rated Operational Voltage | 90 to 347 VAC 50/60 Hz between phase and neutral UL 156 to 600 V AC 50/60 Hz between phases UL 90 to 300 V AC 50/60 Hz between phase and neutral CE 125 to 300 V DC |
| Power Consumption in VA | 5 VA 347 VAC between phase and neutral) 5 VA 600 VAC between phases) |
| Power Consumption in W | 3 W 300 V |
| Ride-through Time | 100 ms 120 VAC |
| Mounting Mode | Clip-on By screws |
| Mounting Support | DIN rail |
| Standards | IEC 61010-1 CSA C22.2 No 14-05 UL 508 |
| Product Certifications | CE conforming to IEC 61010 CULus conforming to UL 508 |
| Relative Humidity | 0 to 95 % |
| Ambient Air Temperature for Operation | -22 to 158°F (-30 to 70°C) |
| Ambient Air Temperature for Storage | -40 to 185°F (-40 to 85°C) |
| Colour | Dark grey |
| 0.35" (9 mm) Pitches | 12 |
| Dimensions | 2.3 x 4.2 x 3.6" (59 x 107 x 91 mm) |