A medium split-core current transformer rated at 600 A primary and 28 kA, featuring a 2.46 x 2.9" (62.48 x 73.7 mm) opening and UL2808 compliance, standard for busbar.
A medium split-core current transformer rated at 600 A primary and 28 kA, featuring a 2.46 x 2.9" (62.48 x 73.7 mm) opening and UL2808 compliance, standard for busbar.
Caractéristiques
| Range | PowerLogic |
| Product or Component Type | Current transformer |
| Accessory / Separate Part Category | Measurement accessory |
| Range Compatibility | PowerLogic PowerLogic PM5000 power meter PowerLogic PowerLogic PM3000 power meter Acti 9 Acti9 iEM3000 energy meter EasyLogic EasyLogic PM2100 power meter EasyLogic EasyLogic PM2200 power meter |
| Current Transformer Type | Split core |
| Primary Operational Current | 600 A |
| Secondary Current | 5 A |
| Network Type | AC |
| Network Frequency | 50 Hz 60 Hz |
| Current Transformer Ratio | 600/5 |
| Electrical Connection | 8' (2.4 m) AWG 16 flying lead |
| Insulation | Basic insulation 600 V AC Reinforced insulation 300 V AC |
| Measurement Accuracy | 1 % |
| Mounting Location | Indoor use only |
| Relative Humidity | 0 to 95 % non condensing |
| Installation Category | III |
| Pollution Degree | 2 |
| Ambient Air Temperature for Operation | 5 to 140°F (-15 to 60 °C) |
| Ambient Air Temperature for Storage | -40 to 158 °F (-40 to 70 °C) |
| Operating Altitude | <= 6561.68' (2000 m) |
| Standards | UL 2808 IEC 61869-2 |
| Product Certifications | UL |
| Dimensions | Total: 1.12 x 5.83 x 5.36" (28.45 x 140.08 x 136.14 mm) Internal: 2.46 x 2.9" (62.48 x 73.7 mm) |
| Weight | 37.2 oz (1054 g) |
| Range | PowerLogic |
| Product or Component Type | Current transformer |
| Accessory / Separate Part Category | Measurement accessory |
| Range Compatibility | PowerLogic PowerLogic PM5000 power meter PowerLogic PowerLogic PM3000 power meter Acti 9 Acti9 iEM3000 energy meter EasyLogic EasyLogic PM2100 power meter EasyLogic EasyLogic PM2200 power meter |
| Current Transformer Type | Split core |
| Primary Operational Current | 600 A |
| Secondary Current | 5 A |
| Network Type | AC |
| Network Frequency | 50 Hz 60 Hz |
| Current Transformer Ratio | 600/5 |
| Electrical Connection | 8' (2.4 m) AWG 16 flying lead |
| Insulation | Basic insulation 600 V AC Reinforced insulation 300 V AC |
| Measurement Accuracy | 1 % |
| Mounting Location | Indoor use only |
| Relative Humidity | 0 to 95 % non condensing |
| Installation Category | III |
| Pollution Degree | 2 |
| Ambient Air Temperature for Operation | 5 to 140°F (-15 to 60 °C) |
| Ambient Air Temperature for Storage | -40 to 158 °F (-40 to 70 °C) |
| Operating Altitude | <= 6561.68' (2000 m) |
| Standards | UL 2808 IEC 61869-2 |
| Product Certifications | UL |
| Dimensions | Total: 1.12 x 5.83 x 5.36" (28.45 x 140.08 x 136.14 mm) Internal: 2.46 x 2.9" (62.48 x 73.7 mm) |
| Weight | 37.2 oz (1054 g) |