Schneider Electric METSECTLV4160U PowerLogic™ Split Core Current Transformer, large, 1600 A, 87 kA

Modèle: METSECTLV4160U

Schneider Electric METSECTLV4160U PowerLogic™ Split Core Current Transformer, large, 1600 A, 87 kA

Modèle: METSECTLV4160U

A large split core current transformer designed for 1600 A primary measurement and 0.333 V secondary output, and rated for a short-time thermal current (Ith) of 87 kA. This is for use with low current monitoring applications.

A large split core current transformer designed for 1600 A primary measurement and 0.333 V secondary output, and rated for a short-time thermal current (Ith) of 87 kA. This is for use with low current monitoring applications.

Prix spécial $269.00 CAD
Prix régulier $422.30 CAD
Disponibilité 2 à 3 semaines
Quantité

Schneider METSECTLV4160U offre

The Split Core Current Sensors from Schneider Electric are a comprehensive offer, ideally suited for low voltage network, from 50 to 2400 A. They deliver secondary output in the form of 0.333 V proportional to the current measured at the primary. They can be used in combination with measurement devices (switchboard instrumentation, Ammeters, kilowatt-hour meters, power-monitoring units, control relays etc.). Split Core CTs are available in four distinctive frame sizes for LVCT options to accomodate different sizes of bus bars or round cables.

Caractéristiques

  • UL2808 Compliant split core current transformer
  • Split core design for ease of installation
  • Compatible with LVCT type panel meters, like EM3000 series
  • Suitable for Ambient upto 140°F (60°C)

Spécifications pour le Schneider METSECTLV4160U

Output at Rated Current 0.333 VAC
Accuracy Class 1 as per IEC 61869-2 (Not applicable for 50 A)
Frequency 50/60 Hz ± 3
Leads 16 AWG Twisted pair; 8' (2.4 m) standard length
Dielectric Strength 5400 Vrms, 60 Hz, 60 s
Rated Dynamic Current (Ith) 2.5" (6.35 cm)
Operating Temperature Range 5 to 140°F (-15 to 60°C)
Storage Temperature Range -40 to 158°F (-40 to 70°C)
Humidity Range 0 to 95% non-condensing
Maximum Voltage L-N Sensed Conductor 600 VAC (insulation rating)
Altitude of Operation 6561.68' (2000 m) maximum
Mounting Location Not suitable for wet locations. For indoor use only
Approvals UL/CSA 61010-1, UL/CSA 61010-2-030, IEC/EN 61010-1, IEC/EN 61010-2-030, EN IEC 62030-2-201, UL/CSA 2808
Installation Category Cat III, pollution degree 2
Dimensions Internal: 2.47 x 5.73" (63 x 146 mm)
Complete: 4.91 x 1.12 x 8.12" (124.71 x 29.46 x 206.25 mm)
Weight 34.8 oz (987 g)

Le Schneider METSECTLV4160U comprend

  • Schneider Electric METSECTLV4160U PowerLogic™ Split Core Current Transformer, large, 1600 A, 87 kA

Poser une question sur le Schneider Electric METSECTLV4160U PowerLogic™ Split Core Current Transformer, large, 1600 A, 87 kA

Schneider METSECTLV4160U offre

The Split Core Current Sensors from Schneider Electric are a comprehensive offer, ideally suited for low voltage network, from 50 to 2400 A. They deliver secondary output in the form of 0.333 V proportional to the current measured at the primary. They can be used in combination with measurement devices (switchboard instrumentation, Ammeters, kilowatt-hour meters, power-monitoring units, control relays etc.). Split Core CTs are available in four distinctive frame sizes for LVCT options to accomodate different sizes of bus bars or round cables.

Caractéristiques

  • UL2808 Compliant split core current transformer
  • Split core design for ease of installation
  • Compatible with LVCT type panel meters, like EM3000 series
  • Suitable for Ambient upto 140°F (60°C)

Spécifications pour le Schneider METSECTLV4160U

Output at Rated Current 0.333 VAC
Accuracy Class 1 as per IEC 61869-2 (Not applicable for 50 A)
Frequency 50/60 Hz ± 3
Leads 16 AWG Twisted pair; 8' (2.4 m) standard length
Dielectric Strength 5400 Vrms, 60 Hz, 60 s
Rated Dynamic Current (Ith) 2.5" (6.35 cm)
Operating Temperature Range 5 to 140°F (-15 to 60°C)
Storage Temperature Range -40 to 158°F (-40 to 70°C)
Humidity Range 0 to 95% non-condensing
Maximum Voltage L-N Sensed Conductor 600 VAC (insulation rating)
Altitude of Operation 6561.68' (2000 m) maximum
Mounting Location Not suitable for wet locations. For indoor use only
Approvals UL/CSA 61010-1, UL/CSA 61010-2-030, IEC/EN 61010-1, IEC/EN 61010-2-030, EN IEC 62030-2-201, UL/CSA 2808
Installation Category Cat III, pollution degree 2
Dimensions Internal: 2.47 x 5.73" (63 x 146 mm)
Complete: 4.91 x 1.12 x 8.12" (124.71 x 29.46 x 206.25 mm)
Weight 34.8 oz (987 g)