Rotronic CL11 Indoor Air Quality Meter/Data Logger

Modèle: 1620.CL11 | No. de commande: CL11

Rotronic CL11 Indoor Air Quality Meter/Data Logger

Modèle: 1620.CL11 | No. de commande: CL11

A benchtop display unit that simultaneously measures and records carbon dioxide, humidity and temperature in order to evaluate the quality of indoor air conditions. 40,000 data point memory.

A benchtop display unit that simultaneously measures and records carbon dioxide, humidity and temperature in order to evaluate the quality of indoor air conditions. 40,000 data point memory.

Votre prix $1218.00 CAD
Disponibilité 1 à 2 semaines
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre CL11 Indoor Air Quality Meter/Data Logger

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre CL11 Indoor Air Quality Meter/Data Logger

Accessoires recommandées


Rotronic 1620.CL11 offre

Caractéristiques

  • Measures and logs CO2, relative humidity and temperature
  • Calculates the dew point and wet bulb temperature
  • Equipped with high accuracy Hygromer® IN-1 humidity sensor
  • Automatic or manual data logging with real time clock
  • 18,000 data point memory for CO2, humidity and temperature values
  • Maximum, minimum and average value display
  • Adjustable audible CO2alarm
  • Display with backlight
  • Adjustable auto power off function
  • Easy field calibration by simple connection to a known reference
  • Mini USB interface

Spécifications pour le Rotronic 1620.CL11

Temperature Range -20 to 60°C
Accuracy <2.5%RH (10 to 90%RH)
Response Time Temp.: 4s; RH: <30s w/o filter; CO<sub>2<10 sec @ 30 cc/min. flow
Accuracy ±0.3°K
Sensor Thermistor
Humidity Range 0 to 100% RH
Sensor HYGROMER® IN-1
CO2 Range 0 to 5000 ppm
Accuracy ±30 ppm ±5% of the measured value
Sensor Non dispersive infrared (NDIR) with automatic baseline correction (ABC)
Recording Capacity 40,000 values with time stamp, automatic recording (%RH /°C / CO2 / external temperature probe)

Le Rotronic 1620.CL11 comprend

  • IAQ Data Logger
  • SW2x Software
  • AC Adapter

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Rotronic CL11 Indoor Air Quality Meter/Data Logger.













Poser une question sur le Rotronic CL11 Indoor Air Quality Meter/Data Logger

Rotronic 1620.CL11 offre

Caractéristiques

  • Measures and logs CO2, relative humidity and temperature
  • Calculates the dew point and wet bulb temperature
  • Equipped with high accuracy Hygromer® IN-1 humidity sensor
  • Automatic or manual data logging with real time clock
  • 18,000 data point memory for CO2, humidity and temperature values
  • Maximum, minimum and average value display
  • Adjustable audible CO2alarm
  • Display with backlight
  • Adjustable auto power off function
  • Easy field calibration by simple connection to a known reference
  • Mini USB interface

Spécifications pour le Rotronic 1620.CL11

Temperature Range -20 to 60°C
Accuracy <2.5%RH (10 to 90%RH)
Response Time Temp.: 4s; RH: <30s w/o filter; CO<sub>2<10 sec @ 30 cc/min. flow
Accuracy ±0.3°K
Sensor Thermistor
Humidity Range 0 to 100% RH
Sensor HYGROMER® IN-1
CO2 Range 0 to 5000 ppm
Accuracy ±30 ppm ±5% of the measured value
Sensor Non dispersive infrared (NDIR) with automatic baseline correction (ABC)
Recording Capacity 40,000 values with time stamp, automatic recording (%RH /°C / CO2 / external temperature probe)

Le Rotronic 1620.CL11 comprend

  • IAQ Data Logger
  • SW2x Software
  • AC Adapter

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Rotronic CL11 Indoor Air Quality Meter/Data Logger.













Poser une question sur le Rotronic CL11 Indoor Air Quality Meter/Data Logger