Cost effective, high-precision and stable transmitter for measuring velocity. The devices have a calorimetric sensor and long-term stability. The range and signal can be configured easily without the use of additional software using dip switches.
Cost effective, high-precision and stable transmitter for measuring velocity. The devices have a calorimetric sensor and long-term stability. The range and signal can be configured easily without the use of additional software using dip switches.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n'y a aucune option de remplacement.
Nous pouvons vous aider à trouver ce dont vous avez besoin:
Caractéristiques
Applications
| Air Flow Rate Measurement | |
| Measurement Technique | Calorimetric |
| Influence of Installation Position | <3 % of measurement with <10° |
| General | |
| Current Consumption | <200 mA |
| Air Flow Rate Measurement | |
| Measurement Range | 2 m/s; 5 m/s; 10 m/s; 15 m/s; 20 m/s |
| Measuring Medium | Air and non-aggressive gases |
| Accuracy | ±3.0% full-scale with 73°F (23°C) ±3 K, 45% RH, 1013 mbar |
| Measurement Interval | 1 s |
| Pressure Resistance | 10 bar |
| Jump Response | τ90 after 3 s |
| Analog Outputs | |
| Number | 1 |
| Analog Output Type | 4 to 20 mA or 0 to 10 V |
| Load | Minimum: <500 Ω (current output)<br> Maximum: >10 kΩ (voltage output) |
| General | |
| Range of Application | 32 to 122°F (0 to 50°C) (housing) 32 to 176°F (0 to 80°C) (medium) |
| Storage Conditions | -4 to 140°F (-20 to 60°C) |
| Power Supply | 8 to 35 VDC or 12 to 30 VAC 50/60 Hz |
| Circuit Type | 3-wire |
| Mounting Position | Sensor at 90° angle to flow |
| Configuration | Via integrated DIP switch |
| Conformity | |
| IP Protection | IP65 |
| CE/EMC Compatibility | EMC Directive 2004/108/EC |
| Housing/Mechanical | |
| Housing Material | Polycarbonate |
| Dimensions | 4.1 x 2.75 x 1.26" (105 x 70 x 32 mm) |
| Electrical Connections | Screw terminals |
| Cable Gland | M12 x 1.5 (Ø cable 0.1 to 0.25" [3 to 6.5 mm]) |
| Weight | Duct version: 5.8 oz (165 g) Cable version: 9.17 oz (260 g) |
| Air Flow Rate Measurement | |
| Measurement Technique | Calorimetric |
| Influence of Installation Position | <3 % of measurement with <10° |
| General | |
| Current Consumption | <200 mA |
| Air Flow Rate Measurement | |
| Measurement Range | 2 m/s; 5 m/s; 10 m/s; 15 m/s; 20 m/s |
| Measuring Medium | Air and non-aggressive gases |
| Accuracy | ±3.0% full-scale with 73°F (23°C) ±3 K, 45% RH, 1013 mbar |
| Measurement Interval | 1 s |
| Pressure Resistance | 10 bar |
| Jump Response | τ90 after 3 s |
| Analog Outputs | |
| Number | 1 |
| Analog Output Type | 4 to 20 mA or 0 to 10 V |
| Load | Minimum: <500 Ω (current output)<br> Maximum: >10 kΩ (voltage output) |
| General | |
| Range of Application | 32 to 122°F (0 to 50°C) (housing) 32 to 176°F (0 to 80°C) (medium) |
| Storage Conditions | -4 to 140°F (-20 to 60°C) |
| Power Supply | 8 to 35 VDC or 12 to 30 VAC 50/60 Hz |
| Circuit Type | 3-wire |
| Mounting Position | Sensor at 90° angle to flow |
| Configuration | Via integrated DIP switch |
| Conformity | |
| IP Protection | IP65 |
| CE/EMC Compatibility | EMC Directive 2004/108/EC |
| Housing/Mechanical | |
| Housing Material | Polycarbonate |
| Dimensions | 4.1 x 2.75 x 1.26" (105 x 70 x 32 mm) |
| Electrical Connections | Screw terminals |
| Cable Gland | M12 x 1.5 (Ø cable 0.1 to 0.25" [3 to 6.5 mm]) |
| Weight | Duct version: 5.8 oz (165 g) Cable version: 9.17 oz (260 g) |